Condition monitoring of induction motor using negative sequence component and THD of the stator current

S. Sridhar, K. Rao, K. Harish, R. Umesh
{"title":"Condition monitoring of induction motor using negative sequence component and THD of the stator current","authors":"S. Sridhar, K. Rao, K. Harish, R. Umesh","doi":"10.1109/POWERI.2016.8077416","DOIUrl":null,"url":null,"abstract":"The Condition Monitoring of Induction Motor (IM) is performed to ensure optimal and reliable operation, as IM has numerous applications spread across varied sectors. Mechanical faults such as Broken Rotor bar fault of IM along with supply PQ disturbances create a high degree of non-linearity in the supply. This non-linearity is examined by stator current signature analysis which involves the computation of the Negative Sequence Components (NSC) and Total Harmonic Distortions (THD) of the stator current. These values are given as inputs to the Artificial Neural Network (ANN), Support Vector Machine (SVM) and k-Nearest Neighbor (kNN) classifiers. The results of the classifiers are obtained and compared. It is seen that the classification accuracy for ANN is found to be 90.63%, while for SVM is found to be 92.71% and that of kNN is found to be 85.41%.","PeriodicalId":332286,"journal":{"name":"2016 IEEE 7th Power India International Conference (PIICON)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 7th Power India International Conference (PIICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERI.2016.8077416","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The Condition Monitoring of Induction Motor (IM) is performed to ensure optimal and reliable operation, as IM has numerous applications spread across varied sectors. Mechanical faults such as Broken Rotor bar fault of IM along with supply PQ disturbances create a high degree of non-linearity in the supply. This non-linearity is examined by stator current signature analysis which involves the computation of the Negative Sequence Components (NSC) and Total Harmonic Distortions (THD) of the stator current. These values are given as inputs to the Artificial Neural Network (ANN), Support Vector Machine (SVM) and k-Nearest Neighbor (kNN) classifiers. The results of the classifiers are obtained and compared. It is seen that the classification accuracy for ANN is found to be 90.63%, while for SVM is found to be 92.71% and that of kNN is found to be 85.41%.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用负序分量和定子电流的THD对异步电动机进行状态监测
异步电机(IM)的状态监测是为了确保最佳和可靠的运行,因为IM在各个领域都有许多应用。机械故障,如IM断转子故障和电源PQ干扰造成了电源的高度非线性。这种非线性通过定子电流特征分析来检验,该分析涉及到定子电流的负序分量(NSC)和总谐波畸变(THD)的计算。这些值作为人工神经网络(ANN)、支持向量机(SVM)和k-最近邻(kNN)分类器的输入。得到了分类器的分类结果并进行了比较。可以看出,ANN的分类准确率为90.63%,SVM的分类准确率为92.71%,kNN的分类准确率为85.41%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Detection of power quality disturbances in the utility grid with solar energy using S-transform Full bridge level doubling network assisted multilevel DC link inverter Distribution system expansion planning incorporating distributed generation A solar PV system controlled by least sum of exponentials algorithm Photo-voltaic system for refrigeration plants in isolated areas
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1