A Wearable, Low-cost Hand Tremor Sensor for Detecting Hypoglycemic Events in Diabetic Patients

H. Abbas, Karim Zahed, L. Alic, Yibo Zhu, F. Sasangohar, Ranjana K. Mehta, M. Lawley, Q. Abbasi, K. Qaraqe
{"title":"A Wearable, Low-cost Hand Tremor Sensor for Detecting Hypoglycemic Events in Diabetic Patients","authors":"H. Abbas, Karim Zahed, L. Alic, Yibo Zhu, F. Sasangohar, Ranjana K. Mehta, M. Lawley, Q. Abbasi, K. Qaraqe","doi":"10.1109/RFM.2018.8846546","DOIUrl":null,"url":null,"abstract":"Severe hypoglycemia leverages complication in diabetes patients: e.g., it increases death rate by a six-fold. Therefore, early detection and prediction of hypoglycemic events are of utmost importance. This publication presents a prototype of a wearable hand-tremor system that detects the onset of hypoglycemic events. The results show the prototype is capable of simulating anticipated frequency and amplitude of the tremor relevant for hypoglycemic events. The initial functional performance-tests demonstrate a maximum error of 4.75% in the detecting the tremor frequency.","PeriodicalId":111726,"journal":{"name":"2018 IEEE International RF and Microwave Conference (RFM)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International RF and Microwave Conference (RFM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RFM.2018.8846546","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Severe hypoglycemia leverages complication in diabetes patients: e.g., it increases death rate by a six-fold. Therefore, early detection and prediction of hypoglycemic events are of utmost importance. This publication presents a prototype of a wearable hand-tremor system that detects the onset of hypoglycemic events. The results show the prototype is capable of simulating anticipated frequency and amplitude of the tremor relevant for hypoglycemic events. The initial functional performance-tests demonstrate a maximum error of 4.75% in the detecting the tremor frequency.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种用于检测糖尿病患者低血糖事件的可穿戴、低成本手部震颤传感器
严重低血糖会影响糖尿病患者的并发症:例如,它会使死亡率增加六倍。因此,早期发现和预测低血糖事件是至关重要的。本出版物介绍了一种可穿戴的手部震颤系统的原型,该系统可以检测低血糖事件的发生。结果表明,该原型能够模拟与低血糖事件相关的震颤的预期频率和幅度。初步的功能性能测试表明,该方法检测震颤频率的最大误差为4.75%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Impact of Blood Vessels on Data Packet Transmission Through the Fat Channel Multibeam Characteristics of an Array Antenna for 5G Mobile Base Station Performance Assessment of a Star Patch Antenna based on RSSI Level in Actual Indoor Environments 2.45 GHz Patch Antenna Based on Thermoplastic Polymer Substrates RFM 2018 Author Index
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1