A preliminary uncertainty analysis of acceleration and displacement measurements on a novel WBV platform for biologic response studies

F. Orsini, A. Scorza, A. Rossi, F. Botta, S. Sciuto, R. D. Giminiani
{"title":"A preliminary uncertainty analysis of acceleration and displacement measurements on a novel WBV platform for biologic response studies","authors":"F. Orsini, A. Scorza, A. Rossi, F. Botta, S. Sciuto, R. D. Giminiani","doi":"10.1109/MeMeA.2016.7533722","DOIUrl":null,"url":null,"abstract":"Over the last decade, many studies have been conducted on the effects of mechanical vibration on the physical hormonal and neuromuscular responses of muscles: in some works the growth hormone response showed a dependence on the acceleration provided by Whole Body Vibration (WBV) platforms with respect to subjects responsiveness. Therefore the accuracy of acceleration measurements related to the excitation system is important and should be assessed. To this aim a preliminary study on the identification and evaluation of the measurement uncertainty sources in the measurement chain of a novel WBV platform developed by the Authors is here proposed. After the main measurement error sources have been identified, a Monte Carlo simulation Method has been implemented to obtain the uncertainty in accelerations and displacements provided by the WBV platform. Since main causes of uncertainty has been identified in the accelerometer sensitivity, its mounting and the data acquisition processing, Results of the test showed a relative uncertainty of about ±4% for acceleration and displacement measurements for frequencies between 20Hz and 60Hz.","PeriodicalId":221120,"journal":{"name":"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"177 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA.2016.7533722","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

Over the last decade, many studies have been conducted on the effects of mechanical vibration on the physical hormonal and neuromuscular responses of muscles: in some works the growth hormone response showed a dependence on the acceleration provided by Whole Body Vibration (WBV) platforms with respect to subjects responsiveness. Therefore the accuracy of acceleration measurements related to the excitation system is important and should be assessed. To this aim a preliminary study on the identification and evaluation of the measurement uncertainty sources in the measurement chain of a novel WBV platform developed by the Authors is here proposed. After the main measurement error sources have been identified, a Monte Carlo simulation Method has been implemented to obtain the uncertainty in accelerations and displacements provided by the WBV platform. Since main causes of uncertainty has been identified in the accelerometer sensitivity, its mounting and the data acquisition processing, Results of the test showed a relative uncertainty of about ±4% for acceleration and displacement measurements for frequencies between 20Hz and 60Hz.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种用于生物反应研究的新型WBV平台上加速度和位移测量的初步不确定性分析
在过去的十年中,许多关于机械振动对肌肉的生理激素和神经肌肉反应的影响的研究已经进行了:在一些工作中,生长激素的反应显示出对全身振动(WBV)平台提供的加速度的依赖。因此,与励磁系统有关的加速度测量的准确性是重要的,应该进行评估。为此,本文提出了一种新型WBV平台测量链中测量不确定度源识别与评估的初步研究。在确定了主要测量误差源后,采用蒙特卡罗仿真方法获得了WBV平台提供的加速度和位移的不确定度。由于在加速度计的灵敏度、安装和数据采集处理中确定了不确定度的主要原因,测试结果表明,频率在20Hz和60Hz之间的加速度和位移测量的相对不确定度约为±4%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Investigation of temperature rise in tissue — Mimicking material induced by a HIFU transducer Influence of fiber Bragg grating length on temperature measurements in laser-irradiated organs Optimal peripheral measurement point for the assessment of preterm patients in intensive care units Classification of cognitive and resting states of the brain using EEG features Scoring systems in dermatology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1