[Effects of the newly developed mandibular retraction system in a rat].

N Shimizu, H Arima, R Imamura, M Nishide, K Suzuki, T Iwasawa
{"title":"[Effects of the newly developed mandibular retraction system in a rat].","authors":"N Shimizu,&nbsp;H Arima,&nbsp;R Imamura,&nbsp;M Nishide,&nbsp;K Suzuki,&nbsp;T Iwasawa","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Authors have developed a mandibular retraction system in a rat that was constructed by arms having a metal mesh, an incisor metal cap, a pair of closed coil springs and a soft plastic collar. The merit of this system is that the anchor is very stable because it is made on the parietal bones, and the direction and load of the traction are invariable regardless of head position of the rat compared to the previous methods in which the anchor was made on the neck collar of a rat. Seventy of 8-week-old male Wistar rats were divided into five groups that were intact, collar, sham operation, straight-pull and high-pull. The anchor was implanted with a metal mesh into the subperiosteal space of the parietal bones just in front of the lambda suture of a rat. The coil spring attached on the sliding hook on the arm was connected with a hook soldered with an incisor metal cap. Therefore, the mandible was retracted in the TMJ direction (straight-pull) and some were 20 degrees upper than TMJ (high-pull) for 15 days at a tension of 10 g. All operations except for traction by the coil springs were performed on a rat in the sham operation group. Only the plastic collar was set on the neck in the collar group. Mandibular retraction for 15 days showed significant inhibition of the sagittal growth of the mandible in both high- and straight-pull groups. No inhibition of sagittal cranial growth was observed according to morphometrical and microscopical investigations.(ABSTRACT TRUNCATED AT 250 WORDS)</p>","PeriodicalId":77579,"journal":{"name":"Nichidai koku kagaku = Nihon University journal of oral science","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1990-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nichidai koku kagaku = Nihon University journal of oral science","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Authors have developed a mandibular retraction system in a rat that was constructed by arms having a metal mesh, an incisor metal cap, a pair of closed coil springs and a soft plastic collar. The merit of this system is that the anchor is very stable because it is made on the parietal bones, and the direction and load of the traction are invariable regardless of head position of the rat compared to the previous methods in which the anchor was made on the neck collar of a rat. Seventy of 8-week-old male Wistar rats were divided into five groups that were intact, collar, sham operation, straight-pull and high-pull. The anchor was implanted with a metal mesh into the subperiosteal space of the parietal bones just in front of the lambda suture of a rat. The coil spring attached on the sliding hook on the arm was connected with a hook soldered with an incisor metal cap. Therefore, the mandible was retracted in the TMJ direction (straight-pull) and some were 20 degrees upper than TMJ (high-pull) for 15 days at a tension of 10 g. All operations except for traction by the coil springs were performed on a rat in the sham operation group. Only the plastic collar was set on the neck in the collar group. Mandibular retraction for 15 days showed significant inhibition of the sagittal growth of the mandible in both high- and straight-pull groups. No inhibition of sagittal cranial growth was observed according to morphometrical and microscopical investigations.(ABSTRACT TRUNCATED AT 250 WORDS)

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[新发展的大鼠下颌骨内收系统的影响]。
作者在大鼠身上开发了一种下颌骨收缩系统,该系统由具有金属网,门牙金属帽,一对封闭线圈弹簧和软塑料项圈的手臂组成。该系统的优点是锚非常稳定,因为它是在顶骨上制作的,与以前的方法相比,锚是在大鼠的颈圈上制作的,无论大鼠的头部位置如何,牵引的方向和负荷都是不变的。将70只8周龄雄性Wistar大鼠分为完整组、颈圈组、假手术组、直拉组和高拉组。将锚钉与金属网一起植入大鼠顶骨骨膜下间隙,位于lambda缝合线前方。将上肢滑动钩上的线圈弹簧与焊接有切牙金属帽的钩连接,使下颌骨在10 g的张力下,向TMJ方向(直拉)内收,部分下颌骨比TMJ(高拉)上收20度,持续15天。假手术组大鼠除螺旋弹簧牵引外,其余手术均行。领口组只在颈部设置塑料领口。下颌牵伸15 d后,高牵伸组和直牵伸组对下颌矢状面生长均有明显抑制作用。根据形态学和显微观察,没有观察到矢状颅生长的抑制。(摘要删节250字)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Differential diagnosis of lymph nodes in oral-maxillary regions by ultrasonography]. [Microflora around the bracket by direct bonding system]. [Objective evaluation of the mandibular position by the change in the function of the middle ear. 1. Centric relation and lateral eccentric position]. [Effects of the newly developed mandibular retraction system in a rat]. [The evaluation of commercially available silane coupling agents for porcelain adhesion].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1