Application of DTS in high-temperature monitoring of alumina electrolysis bath

Zhibin Wen, Zhengji Zhang, Zengjin Lu, Liang Yan, Fubin Ning, Guozhi Cheng, Shixi Zhang, Y. Ning, Tong Liu
{"title":"Application of DTS in high-temperature monitoring of alumina electrolysis bath","authors":"Zhibin Wen, Zhengji Zhang, Zengjin Lu, Liang Yan, Fubin Ning, Guozhi Cheng, Shixi Zhang, Y. Ning, Tong Liu","doi":"10.1117/12.2667785","DOIUrl":null,"url":null,"abstract":"Large alumina electrolysis baths operate at high electrical current and high temperature hence a number of safety hazards. Conventional safety inspection relies on manual temperature monitoring using IR remote thermometers, which is not in real time and not reproducible. This paper presents a distributed fiber optic temperature sensor (DTS) system based on Raman scattering principle. The operation principle and method of deployment of the DTS system in an alumina electrolysis base and on-site monitoring results are discussed. The field measurement results show that the accuracy of the measurement of the distributed fiber optic temperature measurement system meets the application requirements and have great application potential.","PeriodicalId":227067,"journal":{"name":"International Conference on Precision Instruments and Optical Engineering","volume":"219 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Precision Instruments and Optical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2667785","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Large alumina electrolysis baths operate at high electrical current and high temperature hence a number of safety hazards. Conventional safety inspection relies on manual temperature monitoring using IR remote thermometers, which is not in real time and not reproducible. This paper presents a distributed fiber optic temperature sensor (DTS) system based on Raman scattering principle. The operation principle and method of deployment of the DTS system in an alumina electrolysis base and on-site monitoring results are discussed. The field measurement results show that the accuracy of the measurement of the distributed fiber optic temperature measurement system meets the application requirements and have great application potential.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
DTS在氧化铝电解液高温监测中的应用
大型氧化铝电解槽在高电流和高温下运行,因此存在许多安全隐患。传统的安全检查依赖于使用红外远程温度计的人工温度监测,这不是实时的,也不是可复制的。提出了一种基于拉曼散射原理的分布式光纤温度传感器系统。论述了DTS系统在氧化铝电解基地的工作原理、部署方法及现场监测结果。现场测量结果表明,分布式光纤测温系统的测量精度满足应用要求,具有很大的应用潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Light field image array generation for 3D printing image based on backward ray tracing Study on laser degumming and non-destructive technology of rubber press valve Thermal integration analysis of optical machines for space-based laser communications Alignment error correction of five-sensor planar cross magnetic gradient tensor system Research on method of avoiding phase unwrapping error in 3D measurement of gray code
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1