Research on Comparison of Fault Current Fitting Methods for VSC-HVDC Grids

Wang Wenxin, Li Botong, Liu Tao, Liao Chunbo, Li Bin, Wen Weijie
{"title":"Research on Comparison of Fault Current Fitting Methods for VSC-HVDC Grids","authors":"Wang Wenxin, Li Botong, Liu Tao, Liao Chunbo, Li Bin, Wen Weijie","doi":"10.1109/AEEES51875.2021.9403088","DOIUrl":null,"url":null,"abstract":"On the basis of summarizing the calculation methods and characteristics of the fault current of Voltage Source Converter (VSC) based High Voltage Direct Current (HVDC) (VSC-HVDC) grids, the first-order polynomial fitting, exponential fitting and Fourier fitting of fault current are studied in this paper. The effects of three fitting methods of fault currents of fault branches and non-fault branches in a typical 6-terminal true bipolar VSC-HVDC grid under the conditions of pole-to-ground fault, pole-to-pole fault and pole-to-metal return fault are compared. The fitting effect and error under three fitting methods of different fault locations are also analyzed. Through the analysis and induction of specific examples, it is concluded that the results obtained by the Fourier fitting method are the most consistent with the simulation results.","PeriodicalId":356667,"journal":{"name":"2021 3rd Asia Energy and Electrical Engineering Symposium (AEEES)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 3rd Asia Energy and Electrical Engineering Symposium (AEEES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AEEES51875.2021.9403088","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

On the basis of summarizing the calculation methods and characteristics of the fault current of Voltage Source Converter (VSC) based High Voltage Direct Current (HVDC) (VSC-HVDC) grids, the first-order polynomial fitting, exponential fitting and Fourier fitting of fault current are studied in this paper. The effects of three fitting methods of fault currents of fault branches and non-fault branches in a typical 6-terminal true bipolar VSC-HVDC grid under the conditions of pole-to-ground fault, pole-to-pole fault and pole-to-metal return fault are compared. The fitting effect and error under three fitting methods of different fault locations are also analyzed. Through the analysis and induction of specific examples, it is concluded that the results obtained by the Fourier fitting method are the most consistent with the simulation results.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
VSC-HVDC电网故障电流拟合方法比较研究
在总结基于电压源变换器(VSC)的高压直流电网(VSC-HVDC)故障电流计算方法和特点的基础上,研究了故障电流的一阶多项式拟合、指数拟合和傅立叶拟合。比较了典型6端真双极直流电网在极对地故障、极对极故障和极对金属返回故障情况下,故障支路和非故障支路故障电流三种拟合方法的拟合效果。分析了不同故障位置下三种拟合方法的拟合效果和误差。通过对具体算例的分析归纳,得出傅里叶拟合方法得到的结果与仿真结果最为吻合的结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Improve the Dynamic Breakdown Voltage of SOI LDMOS Devices by Eliminating the Effect of Deep Depletion in Substrate Distribution Network Planning Considering loss with new linearization expression A New Method of Maintenance and Repair of Secondary System in Intelligent Substation Short-term EV Charging Load Forecasting Based on GA-GRU Model AC/DC Hybrid Renewable Energy System Coordinated Control and Test Platform
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1