Review: Analysis of exhaled breath condensate in respiratory medicine: methodological aspects and potential clinical applications

P. Montuschi
{"title":"Review: Analysis of exhaled breath condensate in respiratory medicine: methodological aspects and potential clinical applications","authors":"P. Montuschi","doi":"10.1177/1753465807082373","DOIUrl":null,"url":null,"abstract":"Analysis of exhaled breath condensate (EBC) is a noninvasive method for studying the composition of airway lining fluid and has the potential for assessing lung inflammation. EBC is mainly formed by water vapor, but also contains aerosol particles in which several biomolecules including leukotrienes, 8-isoprostane, prostaglandins, hydrogen peroxide, nitric oxide-derived products, and hydrogen ions, have been detected in healthy subjects. Inflammatory mediators in EBC are detected in healthy subjects and some of them are elevated in patients with different lung diseases. Analysis of EBC is completely noninvasive, is particularly suitable for longitudinal studies, and is potentially useful for assessing the response to pharmacological therapy. Identification of selective profiles of biomarkers of lung diseases might also have a diagnostic value. However, EBC analysis currently has important limitations. The lack of standardized procedures for EBC analysis and validation of some analytical techniques makes it difficult comparison of results from different laboratories. Analysis of EBC is currently more useful for relative measures than for quantitative assessment of inflammatory mediators. Reference analytical techniques are required to provide definitive evidence for the presence of some inflammatory mediators in EBC and for their accurate quantitative assessment in this biological fluid. Several methodological issues need to be addressed before EBC analysis can be considered for clinical applications. However, further research in this area is warranted due to the relative lack of noninvasive methods for assessing lung inflammation.","PeriodicalId":364194,"journal":{"name":"Theraputic Advances in Respiratory Disease","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"114","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Theraputic Advances in Respiratory Disease","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1753465807082373","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 114

Abstract

Analysis of exhaled breath condensate (EBC) is a noninvasive method for studying the composition of airway lining fluid and has the potential for assessing lung inflammation. EBC is mainly formed by water vapor, but also contains aerosol particles in which several biomolecules including leukotrienes, 8-isoprostane, prostaglandins, hydrogen peroxide, nitric oxide-derived products, and hydrogen ions, have been detected in healthy subjects. Inflammatory mediators in EBC are detected in healthy subjects and some of them are elevated in patients with different lung diseases. Analysis of EBC is completely noninvasive, is particularly suitable for longitudinal studies, and is potentially useful for assessing the response to pharmacological therapy. Identification of selective profiles of biomarkers of lung diseases might also have a diagnostic value. However, EBC analysis currently has important limitations. The lack of standardized procedures for EBC analysis and validation of some analytical techniques makes it difficult comparison of results from different laboratories. Analysis of EBC is currently more useful for relative measures than for quantitative assessment of inflammatory mediators. Reference analytical techniques are required to provide definitive evidence for the presence of some inflammatory mediators in EBC and for their accurate quantitative assessment in this biological fluid. Several methodological issues need to be addressed before EBC analysis can be considered for clinical applications. However, further research in this area is warranted due to the relative lack of noninvasive methods for assessing lung inflammation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
综述:呼吸医学中呼出冷凝水的分析:方法学方面和潜在的临床应用
呼气冷凝水分析(EBC)是一种无创的方法来研究气道衬液的组成,并有评估肺部炎症的潜力。EBC主要由水蒸气形成,但也含有气溶胶颗粒,其中在健康受试者中检测到几种生物分子,包括白三烯、8-异前列腺素、前列腺素、过氧化氢、一氧化氮衍生产物和氢离子。在健康人群中检测到EBC中的炎症介质,在不同肺部疾病的患者中,有些炎症介质升高。EBC的分析是完全无创的,特别适合于纵向研究,对评估对药物治疗的反应有潜在的用处。鉴定肺部疾病的生物标志物的选择性谱也可能具有诊断价值。然而,EBC分析目前有重要的局限性。由于缺乏标准化的EBC分析程序和某些分析技术的验证,很难比较来自不同实验室的结果。目前,EBC的分析更适用于相对测量,而非炎症介质的定量评估。需要参考分析技术来为EBC中某些炎症介质的存在提供明确的证据,并在这种生物液体中对其进行准确的定量评估。在考虑将EBC分析用于临床应用之前,需要解决几个方法学问题。然而,由于评估肺部炎症的非侵入性方法相对缺乏,这一领域的进一步研究是有必要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Review: Do we need new antibiotics for treating exacerbations of COPD? Review: Systemic consequences of COPD Review: Safety of long-acting β2 -agonists in the treatment of asthma Review: Analysis of exhaled breath condensate in respiratory medicine: methodological aspects and potential clinical applications Review: Rho kinase as a therapeutic target in the treatment of asthma and chronic obstructive pulmonary disease
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1