Thermal Performance Compliance Analysis of Porta-Cabin Shelters Using EN ISO 13786 and EN ISO 6946

M. Obaseki, P. B. Alfred, P. T. Elijah
{"title":"Thermal Performance Compliance Analysis of Porta-Cabin Shelters Using EN ISO 13786 and EN ISO 6946","authors":"M. Obaseki, P. B. Alfred, P. T. Elijah","doi":"10.36347/sjet.2021.v09i10.004","DOIUrl":null,"url":null,"abstract":"Porta Cabin Shelters are temporary dwellings constructed with Sandwich Panels, and used in operational sites by Oil and Gas Firms in Nigeria and Africa. This study carried out thermal performance analysis of Standard Porta Cabin Shelters used in Nigeria Liquified Natural Gas (NLNG) operational Sites using EN ISO 13786: 2017 and ISO 6946:2017 Calculation Methods and Procedures. The Calculation results were tested against the European Building Regulations Part L for compliance. This study reveals that the Porta Cabin shelters failed the compliance test. Analysis for possible compliance was undertaken and the outcome shows that construction of the roof, ceiling and walls with insulator (Sandwich Panels with Polyurethane Foam (PUF) as core materials thickness within the range of 80mm to 120mm) comply with the provision of European Building Regulations. Further analysis shows that adding about 80mm to 110mm thickness of insulator layer to the floor thermal layers will correct the major non-compliance in the floor construction and enhance thermal comfort of the shelters.","PeriodicalId":379926,"journal":{"name":"Scholars Journal of Engineering and Technology","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scholars Journal of Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36347/sjet.2021.v09i10.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Porta Cabin Shelters are temporary dwellings constructed with Sandwich Panels, and used in operational sites by Oil and Gas Firms in Nigeria and Africa. This study carried out thermal performance analysis of Standard Porta Cabin Shelters used in Nigeria Liquified Natural Gas (NLNG) operational Sites using EN ISO 13786: 2017 and ISO 6946:2017 Calculation Methods and Procedures. The Calculation results were tested against the European Building Regulations Part L for compliance. This study reveals that the Porta Cabin shelters failed the compliance test. Analysis for possible compliance was undertaken and the outcome shows that construction of the roof, ceiling and walls with insulator (Sandwich Panels with Polyurethane Foam (PUF) as core materials thickness within the range of 80mm to 120mm) comply with the provision of European Building Regulations. Further analysis shows that adding about 80mm to 110mm thickness of insulator layer to the floor thermal layers will correct the major non-compliance in the floor construction and enhance thermal comfort of the shelters.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于EN ISO 13786和EN ISO 6946的舱内遮蔽物热性能符合性分析
Porta Cabin shelter是用夹心板建造的临时住所,在尼日利亚和非洲的石油和天然气公司的作业现场使用。本研究采用EN ISO 13786: 2017和ISO 6946:2017计算方法和程序,对尼日利亚液化天然气(NLNG)作业场所使用的标准门舱遮蔽物进行了热性能分析。计算结果根据欧洲建筑法规第L部分进行了符合性测试。本研究发现,Porta Cabin的遮蔽物未能通过符合性测试。对可能的合规性进行了分析,结果表明,屋顶、天花板和墙壁的绝缘体(以聚氨酯泡沫(PUF)为核心材料的夹心板厚度在80毫米到120毫米之间)符合欧洲建筑法规的规定。进一步分析表明,在地板保温层上增加约80mm ~ 110mm厚度的保温层,可以纠正地板施工中的主要不合规问题,提高候机楼的热舒适性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Review of Pretreatment Technology for Corn Straw Anaerobic Digestion Advances in Growth-Promoting Rhizobacteria Function on Plant Growth Facilitation and Their Mechanisms An Empirical Study on the Effects of Disputes on Successful Completion of Construction Projects The Concentration of Organic & Ammonium Pollution and their Relationship in River Water: A Case Study The Concentration of Organic & Ammonium Pollution and their Relationship in River Water: A Case Study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1