{"title":"Out-of step and single phasing protection of synchronous chipper motors","authors":"J. Das, Jon D. Steinmetz, Clifton D. Engram, Aaron A. McPhee","doi":"10.1109/PPIC.2015.7165857","DOIUrl":null,"url":null,"abstract":"Chipper motors in pulp and paper mill environment are of special design-the stability on impact loads is one important consideration. The power factor under normal operation will continuously swing due to varying loads. The paper describes guesswork free rigorous calculations of pull out (out-of-step) power factor based on the parameter of an actual installation. Single phasing is rather a rare occurrence; however, such an event has been experienced in an installation due to overheating and arcing at the fuse clips in a NEMA E2 starter of a chipper motor. Discussions on single phase protection of synchronous motors and recommended settings are provided.","PeriodicalId":118880,"journal":{"name":"2015 61st IEEE Pulp and Paper Industry Conference (PPIC)","volume":"194 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 61st IEEE Pulp and Paper Industry Conference (PPIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPIC.2015.7165857","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Chipper motors in pulp and paper mill environment are of special design-the stability on impact loads is one important consideration. The power factor under normal operation will continuously swing due to varying loads. The paper describes guesswork free rigorous calculations of pull out (out-of-step) power factor based on the parameter of an actual installation. Single phasing is rather a rare occurrence; however, such an event has been experienced in an installation due to overheating and arcing at the fuse clips in a NEMA E2 starter of a chipper motor. Discussions on single phase protection of synchronous motors and recommended settings are provided.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
同步切屑电机的失步和单相保护
制浆造纸厂环境中的切屑电机具有特殊的设计,其在冲击载荷下的稳定性是一个重要的考虑因素。正常工作时的功率因数会随着负载的变化而不断摆动。本文介绍了基于实际安装参数的无猜测(不同步)功率因数的严格计算。单相相当罕见;然而,在安装过程中,由于切屑电机的NEMA E2启动器中的保险丝夹过热和电弧而发生过此类事件。对同步电动机单相保护进行了讨论,并给出了建议设置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Improving pulp and paper plant MV transformer protection Practical application of the 2015 NFPA 70E tables Differential protection used with motors, motor controllers and adjustable frequency drives: What you didn't know! Legacy process control system migrations Longevity of an induction motor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1