Can Low Voltage Inverter-Fed Induction Motors Be Designed Allowing Partial Discharge Activity?

L. Lusuardi, A. Rumi, A. Cavallini, Peng Wang, T. Han
{"title":"Can Low Voltage Inverter-Fed Induction Motors Be Designed Allowing Partial Discharge Activity?","authors":"L. Lusuardi, A. Rumi, A. Cavallini, Peng Wang, T. Han","doi":"10.1109/EIC43217.2019.9046548","DOIUrl":null,"url":null,"abstract":"For inverter-fed induction motors, preventing partial discharge inception at all possible operating voltages might cause suboptimal power densities. In this paper we investigate the possibility of designing insulation systems that might tolerate partial discharges incepted with a low probability. Such a result would help a more proper and justified application of corona-resistant magnet wires. Rather than providing an ultimate solution to this complex problem, we want to indicate an approach using the theory of cumulative damage and underline the areas where critical information is missing to achieve this target.","PeriodicalId":340602,"journal":{"name":"2019 IEEE Electrical Insulation Conference (EIC)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC43217.2019.9046548","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

For inverter-fed induction motors, preventing partial discharge inception at all possible operating voltages might cause suboptimal power densities. In this paper we investigate the possibility of designing insulation systems that might tolerate partial discharges incepted with a low probability. Such a result would help a more proper and justified application of corona-resistant magnet wires. Rather than providing an ultimate solution to this complex problem, we want to indicate an approach using the theory of cumulative damage and underline the areas where critical information is missing to achieve this target.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
低压变频感应电机能否允许部分放电?
对于变频感应电机而言,在所有可能的工作电压下防止局部放电可能会导致功率密度不理想。在本文中,我们研究了设计绝缘系统的可能性,该系统可承受低概率的局部放电。这样的结果将有助于更恰当、更合理地应用抗电晕电磁线。我们不是要为这一复杂问题提供终极解决方案,而是要指出一种使用累积损伤理论的方法,并强调为实现这一目标而缺少关键信息的领域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Diagnostic Testing of Power Cable Insulation For Reliable Smart Grid Operation Investigation of the Thickness Effect on DC Breakdown Strength for HVDC Flexible Cable Insulation Associated with Space Charge Classification of Insulating Liquids Thermal Treatment Using Infrared Spectroscopy and Multivariate Statistical Method Study on the Ageing Characteristics of Persea Americana Oil as an Alternative Transformer Insulation oil Evaluation of Nano-Composite XLPE Compound on Accelerated Aging Cable Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1