Feasibility of heartbeat detection behind a wall using CW Doppler radar

S. El-Samad, D. Obeid, G. Zaharia, S. Sadek, G. El Zein
{"title":"Feasibility of heartbeat detection behind a wall using CW Doppler radar","authors":"S. El-Samad, D. Obeid, G. Zaharia, S. Sadek, G. El Zein","doi":"10.1109/MECAP.2016.7790091","DOIUrl":null,"url":null,"abstract":"This paper presents a wireless measurement system for cardiopulmonary activity detection behind a wall. This system generates a continuous wave signal and is used at 2 different frequencies: 2.4 GHz and 10 GHz. The transmitted signal is directed toward the patient's chest situated at 1 m and then reflected. The radar system is based on a vector network analyzer, which measures the phase of S21. The phase variation of S21 contains information about heart and respiration activity. Measurements are carried out every 30 seconds, for a person sitting at a distance of 1 meter, directly in front of the system or behind a wall. Discrete wavelet transform is used as a processing technique to separate heartbeat signal from respiratory signal. The measurements were performed simultaneously with a PC-based electrocardiogram (ECG) which is used as a reference to validate the information extracted from the measured signals.","PeriodicalId":366020,"journal":{"name":"2016 IEEE Middle East Conference on Antennas and Propagation (MECAP)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Middle East Conference on Antennas and Propagation (MECAP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MECAP.2016.7790091","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents a wireless measurement system for cardiopulmonary activity detection behind a wall. This system generates a continuous wave signal and is used at 2 different frequencies: 2.4 GHz and 10 GHz. The transmitted signal is directed toward the patient's chest situated at 1 m and then reflected. The radar system is based on a vector network analyzer, which measures the phase of S21. The phase variation of S21 contains information about heart and respiration activity. Measurements are carried out every 30 seconds, for a person sitting at a distance of 1 meter, directly in front of the system or behind a wall. Discrete wavelet transform is used as a processing technique to separate heartbeat signal from respiratory signal. The measurements were performed simultaneously with a PC-based electrocardiogram (ECG) which is used as a reference to validate the information extracted from the measured signals.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用连续波多普勒雷达探测墙后心跳的可行性
本文介绍了一种用于墙后心肺活动检测的无线测量系统。该系统产生连续波信号,并在两个不同的频率下使用:2.4 GHz和10 GHz。发射信号被定向到位于1米的患者胸部,然后反射。雷达系统基于矢量网络分析仪,测量S21的相位。S21的相位变化包含有关心脏和呼吸活动的信息。测量每30秒进行一次,测量对象是坐在系统正前方或墙后1米距离处的人。采用离散小波变换作为分离心跳信号和呼吸信号的处理技术。测量与基于pc的心电图(ECG)同时进行,心电图作为参考,用于验证从测量信号中提取的信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
3D printed helical antenna with lens A magnetic nano-particle ink for tunable microwave applications A flexible inkjet printed inverted-F antenna on textile Inkjet printed wireless smart bandage Microstrip back-cavity Hilbert Fractal Antenna for experimental detection of breast tumors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1