{"title":"Modeling for error reduction in vibrating beam accelerometers","authors":"P.H. LaFond","doi":"10.1109/PLANS.1992.185830","DOIUrl":null,"url":null,"abstract":"The author discusses the various performance error sources in vibrating beam accelerometers and how the model used affects those errors. The data given are from Sundstrand Data Control's RBA-500 accelerometer. The design goal in the RBA-500 has been to achieve minimum cost, size, and weight while relying on good symmetry and crystal matching to provide the common mode error rejection necessary to reach acceptable tactical grade performance. Two force crystals are necessary to reduce errors to reasonable levels. It is noted that various models are available with different accuracies and computational demands, but the microprocessors coming on line should have no trouble handling the task at high sample rates. The chosen model can be massaged to reduce selected errors.<<ETX>>","PeriodicalId":422101,"journal":{"name":"IEEE PLANS 92 Position Location and Navigation Symposium Record","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE PLANS 92 Position Location and Navigation Symposium Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PLANS.1992.185830","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
The author discusses the various performance error sources in vibrating beam accelerometers and how the model used affects those errors. The data given are from Sundstrand Data Control's RBA-500 accelerometer. The design goal in the RBA-500 has been to achieve minimum cost, size, and weight while relying on good symmetry and crystal matching to provide the common mode error rejection necessary to reach acceptable tactical grade performance. Two force crystals are necessary to reduce errors to reasonable levels. It is noted that various models are available with different accuracies and computational demands, but the microprocessors coming on line should have no trouble handling the task at high sample rates. The chosen model can be massaged to reduce selected errors.<>
讨论了振动梁加速度计的各种性能误差来源以及所采用的模型对这些误差的影响。给出的数据来自Sundstrand data Control的RBA-500加速度计。RBA-500的设计目标是实现最小的成本、尺寸和重量,同时依靠良好的对称性和晶体匹配来提供必要的共模误差抑制,以达到可接受的战术级性能。两个力晶体是必要的,以减少误差到合理的水平。值得注意的是,各种模型具有不同的精度和计算要求,但即将上线的微处理器在处理高采样率的任务时应该没有问题。可以对所选模型进行按摩,以减少所选错误