[The application of 2-dimensional echocardiography to the control of the location of the electrode catheter during endocardial cardiography].

Radiologia diagnostica Pub Date : 1990-01-01
A L Laucjavicius, A S Aidetis, J A Aganauskene, Z I Montvila, P S Serpitis, B I Baver, A S Bartusjaviciene
{"title":"[The application of 2-dimensional echocardiography to the control of the location of the electrode catheter during endocardial cardiography].","authors":"A L Laucjavicius,&nbsp;A S Aidetis,&nbsp;J A Aganauskene,&nbsp;Z I Montvila,&nbsp;P S Serpitis,&nbsp;B I Baver,&nbsp;A S Bartusjaviciene","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Modern methods for treatment of ventricular tachycardia require the exact knowledge of the position of the electrode catheter during intracardiac electrophysiological investigations. X-ray positioning in several projections facilitates the localisation of tachycardia with an accuracy of 4-8 cm2. From eight cadaver hearts schematic diagrams of the right ventricle for two dimensional echocardiography were derived. Endocardiac ventriculocartography under sonographic control was applied in 27 patients 45 times. With this method we were able to detect the electrode catheter in 42 of 45 (93%) patients effectively. Sonographic control facilitates not only the localisation of tachycardia without radiation burden but also its correlation with anatomic ventricular structure which is not possible by roentgenology. 3 negative results were due to negative echoes. In 3 of 5 cases the fulguration of the ventricular tachycardia focus under echo control was possible. Sonographic check up therefore is predilection method for endocardiac ventricular cardiography and can be recommended.</p>","PeriodicalId":20972,"journal":{"name":"Radiologia diagnostica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiologia diagnostica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Modern methods for treatment of ventricular tachycardia require the exact knowledge of the position of the electrode catheter during intracardiac electrophysiological investigations. X-ray positioning in several projections facilitates the localisation of tachycardia with an accuracy of 4-8 cm2. From eight cadaver hearts schematic diagrams of the right ventricle for two dimensional echocardiography were derived. Endocardiac ventriculocartography under sonographic control was applied in 27 patients 45 times. With this method we were able to detect the electrode catheter in 42 of 45 (93%) patients effectively. Sonographic control facilitates not only the localisation of tachycardia without radiation burden but also its correlation with anatomic ventricular structure which is not possible by roentgenology. 3 negative results were due to negative echoes. In 3 of 5 cases the fulguration of the ventricular tachycardia focus under echo control was possible. Sonographic check up therefore is predilection method for endocardiac ventricular cardiography and can be recommended.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
二维超声心动图在心内膜造影中电极导管位置控制中的应用
治疗室性心动过速的现代方法需要在心内电生理检查中准确了解电极导管的位置。x线定位在几个突出点有助于定位心动过速,精度为4- 8cm2。从八具尸体心脏的二维超声心动图中导出了右心室示意图。27例患者行超声控制下的心内室造影45次。通过这种方法,我们在45例患者中有42例(93%)有效地检测到电极导管。超声控制不仅有助于在没有辐射负担的情况下定位心动过速,而且还有助于其与解剖心室结构的相关性,这是x线学无法做到的。3个阴性结果为阴性回波。5例中有3例在超声控制下可出现室性心动过速病灶电灼。因此,超声检查是心内膜室性心动图的优选方法,值得推荐。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Computer Diagnosis of Breast Cancer by Mammogram Processing [Acute changes of coronary and global hemodynamics in patients with angina pectoris and arterial hypertension caused by celiprolol and metoprolol]. [Determination of pressure-volume relations from ventriculographs using catheter tip manometers]. [Method-related complications of balloon catheter valvuloplasty of heart valve stenosis in children and adults]. [Percutaneous transvascular pulmonary valvuloplasty. Early and late results].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1