Estimation of Performance Parameters Using Charge Freed from Deep Traps Located at Interfacial Region of Oil-Paper Insulation

D. Mishra, R. Verma, A. Baral, N. Haque, S. Chakravorti
{"title":"Estimation of Performance Parameters Using Charge Freed from Deep Traps Located at Interfacial Region of Oil-Paper Insulation","authors":"D. Mishra, R. Verma, A. Baral, N. Haque, S. Chakravorti","doi":"10.1109/CATCON47128.2019.CN0058","DOIUrl":null,"url":null,"abstract":"De-trapped charge dislodged from interfacial region of oil-paper insulation can be used as an effective insulation sensitive parameter. Over time, various physiochemical reactions takes place at interfacial region and consequently results in the formation of different trap sites (deep and shallow). Charges which resides at these traps sites are de- trapped after gaining sufficient energy. In present analysis, it is found that charge dislocated from deep traps maintains some specific type of relationship with different insulation sensitive parameters. Before using de-trapped (dislodge from deep traps) as an effective insulation sensitive parameter the effect of geometry must be reduced, as amount of de-trapped charge depends on the area of interfacial region which is not identical for all units. Result presented in this paper shows that use of geometric capacitance for normalization purposes significantly reduces the effects of insulation physical dimensions on de- trapped charge. The capability of deep charge (normalized using dc insulation resistance and geometrical capacitance) is also compared in the present work.","PeriodicalId":183797,"journal":{"name":"2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CATCON47128.2019.CN0058","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

De-trapped charge dislodged from interfacial region of oil-paper insulation can be used as an effective insulation sensitive parameter. Over time, various physiochemical reactions takes place at interfacial region and consequently results in the formation of different trap sites (deep and shallow). Charges which resides at these traps sites are de- trapped after gaining sufficient energy. In present analysis, it is found that charge dislocated from deep traps maintains some specific type of relationship with different insulation sensitive parameters. Before using de-trapped (dislodge from deep traps) as an effective insulation sensitive parameter the effect of geometry must be reduced, as amount of de-trapped charge depends on the area of interfacial region which is not identical for all units. Result presented in this paper shows that use of geometric capacitance for normalization purposes significantly reduces the effects of insulation physical dimensions on de- trapped charge. The capability of deep charge (normalized using dc insulation resistance and geometrical capacitance) is also compared in the present work.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用油纸绝缘界面区深阱释放电荷估计性能参数
从油纸绝缘界面区移出的脱困电荷可以作为有效的绝缘敏感参数。随着时间的推移,不同的物理化学反应发生在界面区域,从而形成不同的陷阱位置(深和浅)。驻留在这些陷阱位置的电荷在获得足够的能量后被释放。分析结果表明,深阱电荷位错与不同的绝缘敏感参数之间存在一定的关系。在使用脱陷(从深阱中移除)作为有效的绝缘敏感参数之前,必须降低几何形状的影响,因为脱陷电荷的数量取决于界面区域的面积,而对于所有单元来说,界面区域的面积并不相同。结果表明,采用几何电容归一化可以显著降低绝缘物理尺寸对脱陷电荷的影响。本文还比较了深层充电的能力(用直流绝缘电阻和几何电容归一化)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Eddy Current and Magneto-Structural Analysis on Transformer Winding with Continuously Transposed Conductors Estimation of Endurance Coefficient of Oil Impregnated Kraft Papers using DEM Effect of filler concentration on breakdown of Isotactic Polypropylene Nano-composites A Novel Autonomous Technique for Early Fault Detection on Overhead Power Lines CATCON 2019 Cover Page
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1