Quantitative Error Analysis in Near-Field Scanning Microwave Microscopy

K. Haddadi, P. Polovodov, D. Théron, G. Dambrine
{"title":"Quantitative Error Analysis in Near-Field Scanning Microwave Microscopy","authors":"K. Haddadi, P. Polovodov, D. Théron, G. Dambrine","doi":"10.1109/MARSS.2018.8481160","DOIUrl":null,"url":null,"abstract":"Near-field scanning microwave microscopy (NSMM) has to face several issues for the establishment of traceable and quantitative data. In particular, at the nanoscale, the wavelength of operation in the microwave regime appears disproportionate compared to the size of the nano-object under investigation. Incidentally, the microwave characterization results in poor electrical sensitivity as the volume of the wave/material interaction is limited to a fraction of the wavelength. In addition, the definition of nanoscale microwave impedance standards requires accurate knowledge of the material and dimensional properties at such scale. In this effort, a quantitative error analysis performed on micrometric metal oxide semiconductor (MOS) structures is proposed. In particular, atomic force microscopy (AFM) image together with the magnitude and phase-shift images of the complex microwave reflection coefficient using a Keysight™'s LS5600 AFM interfaced directly with a vector network analyzer, without electrical matching strategy, are performed around 9.5GHz. From a detailed analysis of the raw data, completed with a FEM-based electromagnetic modeling, quantitative capacitances extraction and system limitations are exemplary shown.","PeriodicalId":118389,"journal":{"name":"2018 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MARSS.2018.8481160","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Near-field scanning microwave microscopy (NSMM) has to face several issues for the establishment of traceable and quantitative data. In particular, at the nanoscale, the wavelength of operation in the microwave regime appears disproportionate compared to the size of the nano-object under investigation. Incidentally, the microwave characterization results in poor electrical sensitivity as the volume of the wave/material interaction is limited to a fraction of the wavelength. In addition, the definition of nanoscale microwave impedance standards requires accurate knowledge of the material and dimensional properties at such scale. In this effort, a quantitative error analysis performed on micrometric metal oxide semiconductor (MOS) structures is proposed. In particular, atomic force microscopy (AFM) image together with the magnitude and phase-shift images of the complex microwave reflection coefficient using a Keysight™'s LS5600 AFM interfaced directly with a vector network analyzer, without electrical matching strategy, are performed around 9.5GHz. From a detailed analysis of the raw data, completed with a FEM-based electromagnetic modeling, quantitative capacitances extraction and system limitations are exemplary shown.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
近场扫描微波显微镜定量误差分析
近场扫描微波显微镜(NSMM)在建立可追溯性和定量数据方面面临着几个问题。特别是,在纳米尺度上,微波波段的工作波长与所研究的纳米物体的尺寸不成比例。顺便说一句,微波表征导致电灵敏度差,因为波/材料相互作用的体积被限制在波长的一小部分。此外,纳米级微波阻抗标准的定义需要对该尺度下的材料和尺寸特性有准确的了解。在这项工作中,提出了对微米金属氧化物半导体(MOS)结构进行定量误差分析的方法。特别是,原子力显微镜(AFM)图像以及复杂微波反射系数的幅度和相移图像,使用Keysight™的LS5600 AFM直接与矢量网络分析仪接口,没有电匹配策略,在9.5GHz左右进行。通过对原始数据的详细分析,以及基于fem的电磁建模,给出了定量电容提取和系统限制的示例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Copyright Information Ferrofluid Levitated Micro/Milli-Robots Implementation Scheme of Orbital Refueling Using Microsate IIite Assembly of Cellular Microstructures into Lobule-Like 3D Microtissues Based on Microrobotic Manipulation* Research supported by the Beijing Natural Science Foundation under Grant 4164099and the National Natural Science Foundation of China under grants 61603044and 61520106011. Three Dimensional Microfabrication Using Local Electrophoretic Deposition Assisted with Laser Trapping Controlled by a Spatial Light Modulator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1