Increasing the Integration Potential of EV Chargers in DC Trolleygrids: A Bilateral Substation-Voltage Tuning Approach

I. Diab, G. C. Mouli, P. Bauer
{"title":"Increasing the Integration Potential of EV Chargers in DC Trolleygrids: A Bilateral Substation-Voltage Tuning Approach","authors":"I. Diab, G. C. Mouli, P. Bauer","doi":"10.1109/speedam53979.2022.9841989","DOIUrl":null,"url":null,"abstract":"Light rail networks such as trolleybus grids have the potential to become multi-functional smart grids by using the excess capacity of the grid to implement PV systems, EV chargers, and storage. This paper offers a solution to increasing the potential for integration of EV chargers in the trolleygrid, without additional infrastructure costs, by simply tuning the nominal (no-load) voltages of bilaterally connected substations. This method shifts the load share between the two substations, creating more room for the integration of other utilities in a desired zone of the bus route. A mathematical derivation is presented, followed by a verifying case study using detailed and verified bus and trolleygrid simulation models for the city of Arnhem, the Netherlands. It is shown that by setting a substation nominal voltage from +10V compared to its bilateral substation to -10V, the substation can take, on average, as much as 7.5 percentage points less of the load share (from 45.9% to 38.4%) and see as much as 5 percentage points more of complete zero-load time (84.3% to 89.2%).","PeriodicalId":365235,"journal":{"name":"2022 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/speedam53979.2022.9841989","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

Light rail networks such as trolleybus grids have the potential to become multi-functional smart grids by using the excess capacity of the grid to implement PV systems, EV chargers, and storage. This paper offers a solution to increasing the potential for integration of EV chargers in the trolleygrid, without additional infrastructure costs, by simply tuning the nominal (no-load) voltages of bilaterally connected substations. This method shifts the load share between the two substations, creating more room for the integration of other utilities in a desired zone of the bus route. A mathematical derivation is presented, followed by a verifying case study using detailed and verified bus and trolleygrid simulation models for the city of Arnhem, the Netherlands. It is shown that by setting a substation nominal voltage from +10V compared to its bilateral substation to -10V, the substation can take, on average, as much as 7.5 percentage points less of the load share (from 45.9% to 38.4%) and see as much as 5 percentage points more of complete zero-load time (84.3% to 89.2%).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
提高直流有轨电车电网中电动汽车充电器的集成潜力:一种双边变电站电压调谐方法
轻轨网络,如无轨电车电网,有潜力成为多功能智能电网,利用电网的过剩容量来实施光伏系统、电动汽车充电器和存储。本文提供了一种解决方案,通过简单地调整双边连接变电站的标称(空载)电压,在不增加额外基础设施成本的情况下,增加电动汽车充电器在有轨电车电网中的整合潜力。这种方法转移了两个变电站之间的负荷分担,在公交线路的期望区域为其他公用事业的整合创造了更多的空间。给出了一个数学推导,然后使用荷兰阿纳姆市的详细和验证的公共汽车和无轨电车网格仿真模型进行了验证案例研究。结果表明,通过将变电站标称电压从+10V设置为与其双边变电站相比的-10V,变电站平均可以减少7.5个百分点的负载份额(从45.9%降至38.4%),并看到多达5个百分点的完全零负载时间(84.3%至89.2%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Reduced 2nd Harmonic Input Current Ripple Quasi Z-source Microinverter for On-Grid PV Power Conversion A Review of Shore Infrastructures for Electric Ferries Advanced Edge Computing Framework for Grid Power Quality Monitoring of Industrial Motor Drive Applications Stability Studies of Power Systems for More Electric Aircraft An Optimal Sliding-Integral-Derivative (SID) Control of a Grid-Tied Multilevel Inverter under Parameters Mismatch
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1