{"title":"Biventricular Assist Devices for Acute Heart Failure After Orthotopic Liver Transplantation","authors":"Anushi Shah, M. Fruscione","doi":"10.47363/jccsr/2022(4)214","DOIUrl":null,"url":null,"abstract":"Background: Medical comorbidities augment surgical risk of liver transplantation. This is a report of immediate post-operative biventricular failure following liver transplant requiring venoarterial extracorporeal membrane oxygenation (VA-ECMO) and subsequent conversion to minimally invasive biventricular assist devices (BIVAD) for cardiac recovery and liver graft preservation. Case Report: 66-year-old male decompensated alcoholic cirrhotic with a pre-operative stress echocardiogram (ECHO) showing no significant valvular or coronary disease and a left ventricular ejection fraction (LVEF) of 65% underwent liver transplantation. Transesophageal echocardiogram at the conclusion of the case demonstrated a LVEF of 10% with biventricular dysfunction and severe mitral regurgitation requiring four pressors. VA-ECMO was initiated for temporary stabilization with subsequent transition to biventricular support using an Impella® 5.5 left ventricular device (VAD) via axillary artery graft and a Protek-Duo percutaneous right VAD via the right internal jugular vein, both placed peripherally through a minimally invasive approach. Serial echocardiograms showed recovery of myocardial function. BIVAD were removed on day 8 and day 13. Excellent liver function was maintained. Conclusion: This is the first report of minimally invasive BIVAD used for acute cardiogenic shock after liver transplantation. A multidisciplinary team approach to prompt mechanical support ensured preservation of liver graft while allowing for cardiac recovery.","PeriodicalId":274729,"journal":{"name":"Journal of Clinical Case Studies Reviews & Reports","volume":"115 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Case Studies Reviews & Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47363/jccsr/2022(4)214","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Medical comorbidities augment surgical risk of liver transplantation. This is a report of immediate post-operative biventricular failure following liver transplant requiring venoarterial extracorporeal membrane oxygenation (VA-ECMO) and subsequent conversion to minimally invasive biventricular assist devices (BIVAD) for cardiac recovery and liver graft preservation. Case Report: 66-year-old male decompensated alcoholic cirrhotic with a pre-operative stress echocardiogram (ECHO) showing no significant valvular or coronary disease and a left ventricular ejection fraction (LVEF) of 65% underwent liver transplantation. Transesophageal echocardiogram at the conclusion of the case demonstrated a LVEF of 10% with biventricular dysfunction and severe mitral regurgitation requiring four pressors. VA-ECMO was initiated for temporary stabilization with subsequent transition to biventricular support using an Impella® 5.5 left ventricular device (VAD) via axillary artery graft and a Protek-Duo percutaneous right VAD via the right internal jugular vein, both placed peripherally through a minimally invasive approach. Serial echocardiograms showed recovery of myocardial function. BIVAD were removed on day 8 and day 13. Excellent liver function was maintained. Conclusion: This is the first report of minimally invasive BIVAD used for acute cardiogenic shock after liver transplantation. A multidisciplinary team approach to prompt mechanical support ensured preservation of liver graft while allowing for cardiac recovery.