[Measurements of the mercury vapour concentration of the room air during dosing and trituration of amalgam by DMG 410].

Stomatologie der DDR Pub Date : 1990-08-01
E Glockmann, G Holzapfel, J Güsewell
{"title":"[Measurements of the mercury vapour concentration of the room air during dosing and trituration of amalgam by DMG 410].","authors":"E Glockmann,&nbsp;G Holzapfel,&nbsp;J Güsewell","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The testet mechanical amalgamators DMG 410 (VEB Dentalfabrik Treffurt) showed sufficient tightness. After dosing and trituration of 5 (during 30 min) and of 25 amalgam mixtures (during 2 hours) an increase of the mercury vapour concentration was measured from 0.003 mg Hg/m3 air of the room (blank value) to 0.008 mg Hg/m3 air of the room and to 0.018 mg Hg/m3 air of the room in an unventilated room. A significant decrease of the mercury vapour concentration could be established within 10 minutes by ventilation of the measurement room.</p>","PeriodicalId":76559,"journal":{"name":"Stomatologie der DDR","volume":"40 8","pages":"333-4"},"PeriodicalIF":0.0000,"publicationDate":"1990-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Stomatologie der DDR","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The testet mechanical amalgamators DMG 410 (VEB Dentalfabrik Treffurt) showed sufficient tightness. After dosing and trituration of 5 (during 30 min) and of 25 amalgam mixtures (during 2 hours) an increase of the mercury vapour concentration was measured from 0.003 mg Hg/m3 air of the room (blank value) to 0.008 mg Hg/m3 air of the room and to 0.018 mg Hg/m3 air of the room in an unventilated room. A significant decrease of the mercury vapour concentration could be established within 10 minutes by ventilation of the measurement room.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[用DMG 410给汞合金加药和加盐期间室内空气中汞蒸气浓度的测量]。
试验机械混合器dmg410 (VEB Dentalfabrik Treffurt)显示出足够的密封性。在给5(30分钟)和25(2小时)汞合金混合物加药和营养后,测量到汞蒸气浓度从房间空气的0.003 mg Hg/m3(空白值)增加到房间空气的0.008 mg Hg/m3,在不通风的房间中增加到房间空气的0.018 mg Hg/m3。通过对测量室进行通风,可以在10分钟内确定汞蒸气浓度的显著降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Renewed examination of the group classification of partially edentulous arches by Eichner and application advices for studies on morbidity statistics]. [In vitro evaluation of two composite material for posterior restorations]. [Measurements of the mercury vapour concentration of the room air during dosing and trituration of amalgam by DMG 410]. [Investigations of sensitivity and reliability from Plaque-Index methods]. [Vertical movement of teeth following preparation for inlays with preservation of cavity walls].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1