Jianye Wang, Chengshuo Deng, Shibo Zhang, Xiaoshuai Guo, Guoan Yang
{"title":"Research on Vibration Control in a Reciprocating Compressor Piping System Using an Orifice Tube Structure","authors":"Jianye Wang, Chengshuo Deng, Shibo Zhang, Xiaoshuai Guo, Guoan Yang","doi":"10.1109/IICSPI48186.2019.9095967","DOIUrl":null,"url":null,"abstract":"With the severe piping vibration caused by the gas pulsation of the reciprocating compressor, installing the orifice plate near the large container of the pipe system is an effective and simple solution for decreasing the gas pulsation in the field. In this paper, the fluid dynamics analysis proves that the improved orifice tube structure can better decrease the gas pulsation, and it is effective to reduce the piping vibration of a reciprocating compressor unit which is caused by the gas pulsation. The gas pulsation amplitude in the compressor pipeline system is decreased fundamentally by using the orifice tube, and the unit is in good running condition after the transformation, which effectively guarantees the long-term stable operation of the unit.","PeriodicalId":318693,"journal":{"name":"2019 2nd International Conference on Safety Produce Informatization (IICSPI)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 2nd International Conference on Safety Produce Informatization (IICSPI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IICSPI48186.2019.9095967","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
With the severe piping vibration caused by the gas pulsation of the reciprocating compressor, installing the orifice plate near the large container of the pipe system is an effective and simple solution for decreasing the gas pulsation in the field. In this paper, the fluid dynamics analysis proves that the improved orifice tube structure can better decrease the gas pulsation, and it is effective to reduce the piping vibration of a reciprocating compressor unit which is caused by the gas pulsation. The gas pulsation amplitude in the compressor pipeline system is decreased fundamentally by using the orifice tube, and the unit is in good running condition after the transformation, which effectively guarantees the long-term stable operation of the unit.