Three-phase symmetrical short circuit current characteristic analysis of doubly fed induction generator with crowbar protection

Zhai Jiajun, Zhang Bu-han, Wang Kui, Shao Wen
{"title":"Three-phase symmetrical short circuit current characteristic analysis of doubly fed induction generator with crowbar protection","authors":"Zhai Jiajun, Zhang Bu-han, Wang Kui, Shao Wen","doi":"10.1109/ISGT-ASIA.2012.6303162","DOIUrl":null,"url":null,"abstract":"When there has a sudden drop of grid voltage, crowbar protection circuit is a widely used method to improve the low voltage ride-through ability of wind turbines with doubly fed induction generator (DFIG), which is commonly used in wind power. This paper studied three-phase symmetrical short circuit current characteristics of DFIG with crowbar protection in depth, and simulations have been made in PSCAD/EMTDC. The analysis and simulation results show that, the output short circuit current concerns with crowbar resistance, dc-link voltage clamp effect and control strategies of the grid side converter (GSC). Short circuit current characteristics of a DFIG wind turbine become complicated because of the responses of GSC, when the dc-link clamp effect occurs. The GSC will also provide a high current to the short circuit point. However, when necessary restrictions have been introduced, short circuit current of DFIG wind turbine can be substituted by stator winding short circuit current of the DFIG whether the dc-link clamp effect occurs or not. Thus, on the basis of previous analysis results, we got short circuit current expressions of a DFIG under no dc-link clamp effect, when short circuit occurred at the normal operation. And an impedance voltage source model was proposed and has been verified at last.","PeriodicalId":330758,"journal":{"name":"IEEE PES Innovative Smart Grid Technologies","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE PES Innovative Smart Grid Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-ASIA.2012.6303162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

When there has a sudden drop of grid voltage, crowbar protection circuit is a widely used method to improve the low voltage ride-through ability of wind turbines with doubly fed induction generator (DFIG), which is commonly used in wind power. This paper studied three-phase symmetrical short circuit current characteristics of DFIG with crowbar protection in depth, and simulations have been made in PSCAD/EMTDC. The analysis and simulation results show that, the output short circuit current concerns with crowbar resistance, dc-link voltage clamp effect and control strategies of the grid side converter (GSC). Short circuit current characteristics of a DFIG wind turbine become complicated because of the responses of GSC, when the dc-link clamp effect occurs. The GSC will also provide a high current to the short circuit point. However, when necessary restrictions have been introduced, short circuit current of DFIG wind turbine can be substituted by stator winding short circuit current of the DFIG whether the dc-link clamp effect occurs or not. Thus, on the basis of previous analysis results, we got short circuit current expressions of a DFIG under no dc-link clamp effect, when short circuit occurred at the normal operation. And an impedance voltage source model was proposed and has been verified at last.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
带撬棍保护的双馈感应发电机三相对称短路电流特性分析
在电网电压突然下降的情况下,为提高风力发电中常用的双馈感应发电机(DFIG)风力发电机组的低压通过能力,采用了一种被广泛采用的保护电路。本文深入研究了带撬棍保护的DFIG三相对称短路电流特性,并在PSCAD/EMTDC中进行了仿真。分析和仿真结果表明,输出短路电流与栅极侧变流器(GSC)的锁阻、直流电压钳位效应和控制策略有关。当直流链路钳位效应发生时,由于GSC的响应,DFIG风电机组的短路电流特性变得复杂。GSC还将为短路点提供高电流。然而,当引入必要的限制条件时,无论是否发生直流链路箝位效应,DFIG风机的定子绕组短路电流都可以代替DFIG风机的短路电流。由此,在前面分析结果的基础上,我们得到了无直流钳位效应下,DFIG正常工作时发生短路时的短路电流表达式。提出了一种阻抗电压源模型,并进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Wind-photovoltaic-storage system optimal control scheme based on generation scheduling Smart grid oriented smart substation characteristics analysis Studies on practical Small Signal Stability Region of electrical power systems A survey of communication technology in distribution network An interior point method based on continuous Newton's method for optimal power flow
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1