Comparative Analysis of the Environmental Load of Natural Refrigerant (R290)

Houria Bouzghiba, G. Géczi
{"title":"Comparative Analysis of the Environmental Load of Natural Refrigerant (R290)","authors":"Houria Bouzghiba, G. Géczi","doi":"10.33038/jcegi.3506","DOIUrl":null,"url":null,"abstract":"Due to the detrimental environmental consequences of synthetic refrigerants, natural refrigerants have gained renewed interest as alternative refrigerants for a variety of applications due to their minimal ozone depletion potential (ODP) and insignificant global warming potential (GWP). This study compares the performance characteristics of R32-based Air Source Heat Pump (ASHP) to those of R290 and R410A refrigerants. In this study, analyses of the cooling effect, heat output, compressor work input, and coefficient of performance (COP) for various refrigerants will be undertaken. Additionally, the environmental consequences of R32, R410A, and R290 are discussed. The results indicate that R290 is the most efficient refrigerant in terms of performance coefficient, followed by R410A and R32. Considering environmental protection aspects, R290 is a favorable substitute medium.","PeriodicalId":441221,"journal":{"name":"Journal of Central European Green Innovation","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Central European Green Innovation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33038/jcegi.3506","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Due to the detrimental environmental consequences of synthetic refrigerants, natural refrigerants have gained renewed interest as alternative refrigerants for a variety of applications due to their minimal ozone depletion potential (ODP) and insignificant global warming potential (GWP). This study compares the performance characteristics of R32-based Air Source Heat Pump (ASHP) to those of R290 and R410A refrigerants. In this study, analyses of the cooling effect, heat output, compressor work input, and coefficient of performance (COP) for various refrigerants will be undertaken. Additionally, the environmental consequences of R32, R410A, and R290 are discussed. The results indicate that R290 is the most efficient refrigerant in terms of performance coefficient, followed by R410A and R32. Considering environmental protection aspects, R290 is a favorable substitute medium.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
天然制冷剂(R290)环境负荷对比分析
由于合成制冷剂对环境的有害影响,天然制冷剂因其最小的臭氧消耗潜能值(ODP)和微不足道的全球变暖潜能值(GWP)而重新成为各种应用的替代制冷剂。本研究将基于r32的空气源热泵(ASHP)与R290和R410A制冷剂的性能特性进行了比较。本研究将分析各种制冷剂的冷却效果、热量输出、压缩机功输入和性能系数(COP)。此外,还讨论了R32、R410A和R290对环境的影响。结果表明,R290的性能系数最高,R410A次之,R32次之。从环保角度考虑,R290是一种较好的替代介质。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Strategies for Reducing Arsenic Content in Rice: A review Investigation of the Physiological Effects of Plant Conditioners in Field Experiments of Winter Wheat Evaluating the Capability of Woody Plants to Capture Atmospheric Heavy Metals in Budapest Wing Dimorphism/polymorphism in True Bugs (Heteroptera) From a Functional Viewpoint: A review Plant Protection Practises and Their Impact on Environment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1