Distortion free improved reference current generation algorithm for interleaved inverter based shunt APF

Vijayakumar Gali, N. Gupta, R. A. Gupta
{"title":"Distortion free improved reference current generation algorithm for interleaved inverter based shunt APF","authors":"Vijayakumar Gali, N. Gupta, R. A. Gupta","doi":"10.1109/APPEEC.2017.8308923","DOIUrl":null,"url":null,"abstract":"This paper presents three-phase interleaved inverter topology to enhance the operation of shunt active power filter (SAPF) for mitigating current harmonics, reactive power, shoot-through problem, etc. Conventional voltage source inverter (VSI) has failure mode of operation which causes to damage the power switches. This proposed interleaved inverter avoid conduction through same leg switches. Therefore, no shoot-through mode in the circuit operation of the interleaved SAPF. The proposed interleaved SAPF uses a modified indirect current control technique for generating distorted free reference current. Therefore, switching notches and ripples have been eliminated in the source current which improves the source current %THD. The performance of proposed interleaved SAPF and control algorithm has been designed and tested in MATLAB/ Simulink environment. The proposed interleaved SAPF with proposed control algorithm is effectively mitigating current harmonics, reactive power for unity power factor operation and removes the notches in the source current without shoot-through problems. The complete simulation results have been presented.","PeriodicalId":247669,"journal":{"name":"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"209 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC.2017.8308923","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

This paper presents three-phase interleaved inverter topology to enhance the operation of shunt active power filter (SAPF) for mitigating current harmonics, reactive power, shoot-through problem, etc. Conventional voltage source inverter (VSI) has failure mode of operation which causes to damage the power switches. This proposed interleaved inverter avoid conduction through same leg switches. Therefore, no shoot-through mode in the circuit operation of the interleaved SAPF. The proposed interleaved SAPF uses a modified indirect current control technique for generating distorted free reference current. Therefore, switching notches and ripples have been eliminated in the source current which improves the source current %THD. The performance of proposed interleaved SAPF and control algorithm has been designed and tested in MATLAB/ Simulink environment. The proposed interleaved SAPF with proposed control algorithm is effectively mitigating current harmonics, reactive power for unity power factor operation and removes the notches in the source current without shoot-through problems. The complete simulation results have been presented.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于交错逆变器的并联有源滤波器无失真改进参考电流产生算法
本文提出了一种三相交错逆变器拓扑结构,以增强并联型有源电力滤波器(SAPF)的运行能力,以减轻电流谐波、无功功率、穿透问题等。传统的电压源逆变器(VSI)存在故障运行模式,导致电源开关损坏。本文提出的交错逆变器避免了通过同一分支开关导通。因此,交错式SAPF的电路操作中没有透射模式。所提出的交错SAPF采用一种改进的间接电流控制技术来产生畸变自由参考电流。因此,消除了源电流中的开关陷波和纹波,提高了源电流%THD。在MATLAB/ Simulink环境下设计并测试了所提出的交错SAPF和控制算法的性能。所提出的交错SAPF控制算法有效地减轻了单位功率因数运行时的电流谐波和无功功率,并消除了源电流中的缺口,没有穿透问题。给出了完整的仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A novel modulation strategy for active rectification of a snubber less soft-switched single stage 30 high frequency link DC-AC converter Implementation of social spider optimization for optimized hydel-thermic operational delineation Frequency Response Analysis (FRA) in power transformers: An approach to locate inter-disk SC fault Fault estimation with analytical cable model for MMC-HVDC in offshore applications Modified current control technique for grid synchronization in voltage source converters
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1