{"title":"Control strategy for bi-directional DC/DC converter of a stand-alone wind power system","authors":"Chongyi Tian, Chenghui Zhang, Ke Li, Xiaoguang Chu, N. Cui, Jihong Wang","doi":"10.1109/PEDG.2012.6254017","DOIUrl":null,"url":null,"abstract":"A novel topology with a bi-directional DC/DC for stand-alone wind power system is adopted, which can maximize the battery life by monitoring and controlling its state of charge(soc) and charge/discharge process. According to the atmospheric conditions, the state of charge of the battery and the load conditions, six possible operation modes of the bi-directional DC/DC are also expounded. This paper proposes a hybrid control strategy with the combination of the PI control and the direct output current control to avoid the voltage surge of the DC bus caused by the mode switching. A 5kW wind power system test bench is developed to verify the effectiveness of the control strategy. The experimental results show that the voltage surge can be limited within 5% and the controller performs well in various wind speed and load conditions.","PeriodicalId":146438,"journal":{"name":"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDG.2012.6254017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

A novel topology with a bi-directional DC/DC for stand-alone wind power system is adopted, which can maximize the battery life by monitoring and controlling its state of charge(soc) and charge/discharge process. According to the atmospheric conditions, the state of charge of the battery and the load conditions, six possible operation modes of the bi-directional DC/DC are also expounded. This paper proposes a hybrid control strategy with the combination of the PI control and the direct output current control to avoid the voltage surge of the DC bus caused by the mode switching. A 5kW wind power system test bench is developed to verify the effectiveness of the control strategy. The experimental results show that the voltage surge can be limited within 5% and the controller performs well in various wind speed and load conditions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
单机风力发电系统双向DC/DC变换器控制策略
采用一种新颖的单机风电系统双向DC/DC拓扑结构,通过监测和控制电池荷电状态(soc)和充放电过程,最大限度地延长电池寿命。根据大气条件、蓄电池的充电状态和负载情况,阐述了双向DC/DC的六种可能的工作方式。本文提出了一种PI控制与直接输出电流控制相结合的混合控制策略,以避免直流母线因模式切换而产生的电压浪涌。为验证控制策略的有效性,建立了5kW风力发电系统试验台。实验结果表明,该控制器可将电压浪涌控制在5%以内,在各种风速和负载条件下均表现良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Smart — STATCOM control strategy implementation in wind power plants Common DC link in residential LV network to improve the penetration level of Small-Scale Embedded Generators Research on the reactive power optimization of distribution network including DG Use of petri nets for load sharing control in distributed generation applications Mega data center architecture under Smart Grid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1