{"title":"Modulation transfer function evaluation of cone beam computed and microcomputed tomography by using slanted edge phantom","authors":"S. Bence","doi":"10.24294/MIPT.V0I0.1102","DOIUrl":null,"url":null,"abstract":"Modulation transfer function (MTF) is a well known and widely accepted method for evaluating the spatial resolution of a digital radiographic imaging system. In the present study our aim was to evaluate the MTF obtained from CBCT and micro-CT images. A cylinder shaped phantom designed for slanted-edge method was scanned by a CBCT device at a 100 µm isometric voxel size and by a micro-CT device at a 20 µm isometric voxel size, simultaneously. The MTF curves were calculated and the mean spatial resolutions at 10% MTF were 3.33 + 0.29 lp/mm in the case of CBCT images and 13.35 + 2.47 lp/mm in the case of micro-CT images. The values showed a strong positive correlation regarding the CBCT and the micro-CT spatial resolution values, respectively. Our results suggests that CBCT imaging devices with a voxel size of 100 µm or below might aid the validation of fine anatomical structures and allowing the opportunity for reliable micromorphometric examinations","PeriodicalId":282599,"journal":{"name":"Medical Imaging Process & Technology","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Imaging Process & Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24294/MIPT.V0I0.1102","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Modulation transfer function (MTF) is a well known and widely accepted method for evaluating the spatial resolution of a digital radiographic imaging system. In the present study our aim was to evaluate the MTF obtained from CBCT and micro-CT images. A cylinder shaped phantom designed for slanted-edge method was scanned by a CBCT device at a 100 µm isometric voxel size and by a micro-CT device at a 20 µm isometric voxel size, simultaneously. The MTF curves were calculated and the mean spatial resolutions at 10% MTF were 3.33 + 0.29 lp/mm in the case of CBCT images and 13.35 + 2.47 lp/mm in the case of micro-CT images. The values showed a strong positive correlation regarding the CBCT and the micro-CT spatial resolution values, respectively. Our results suggests that CBCT imaging devices with a voxel size of 100 µm or below might aid the validation of fine anatomical structures and allowing the opportunity for reliable micromorphometric examinations