Flexible Inductance Pressure Sensor for Wearable Electronic Devices

IF 0.6 4区 工程技术 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC Journal of Nanoelectronics and Optoelectronics Pub Date : 2023-06-01 DOI:10.1166/jno.2023.3437
Yizhu Wang, Huiqin Qu, Shu Diao
{"title":"Flexible Inductance Pressure Sensor for Wearable Electronic Devices","authors":"Yizhu Wang, Huiqin Qu, Shu Diao","doi":"10.1166/jno.2023.3437","DOIUrl":null,"url":null,"abstract":"Currently, wearable devices have higher requirements for flexible sensors based on environmental adaptability. Therefore, in order to solve the problem of low sensitivity of current flexible sensors, a new type of flexible inductance pressure sensor is proposed by introducing a ferrite film with high permeability into traditional flexible sensors. The validity and practicability of this method are verified by the research. The results show that the correlation curve of theoretical prediction shows the same trend as the actual curve. Sensor A showed the highest sensitivity of 1.61 kPa −1 ; Under different bending conditions, the sensitivity difference is 0 ∼ 0.20. When the actual external pressure is increased from 0 to 13.6 Pa, the actual change of inductance is about 0.88%. When the excitation voltage is 0.5 V, the actual inductance output value of sensor A increases from the initial 13.22 μ H to 13.26 μ H, and the actual change rate is less than 0.30%. In the application of wearable devices, the keys of wearable electronic keyboard have the maximum output voltage variation value, which is greater than 0.15 V, improving the high stability and practicality of the sensor. It is also practical in wearable human respiratory signal detection equipment. In summary, the flexible inductance pressure sensor designed in this study has high performance and practicability in the application of wearable electronic devices, which is of great significance to the development of actual wearable electronic devices.","PeriodicalId":16446,"journal":{"name":"Journal of Nanoelectronics and Optoelectronics","volume":"23 1","pages":"0"},"PeriodicalIF":0.6000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nanoelectronics and Optoelectronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1166/jno.2023.3437","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Currently, wearable devices have higher requirements for flexible sensors based on environmental adaptability. Therefore, in order to solve the problem of low sensitivity of current flexible sensors, a new type of flexible inductance pressure sensor is proposed by introducing a ferrite film with high permeability into traditional flexible sensors. The validity and practicability of this method are verified by the research. The results show that the correlation curve of theoretical prediction shows the same trend as the actual curve. Sensor A showed the highest sensitivity of 1.61 kPa −1 ; Under different bending conditions, the sensitivity difference is 0 ∼ 0.20. When the actual external pressure is increased from 0 to 13.6 Pa, the actual change of inductance is about 0.88%. When the excitation voltage is 0.5 V, the actual inductance output value of sensor A increases from the initial 13.22 μ H to 13.26 μ H, and the actual change rate is less than 0.30%. In the application of wearable devices, the keys of wearable electronic keyboard have the maximum output voltage variation value, which is greater than 0.15 V, improving the high stability and practicality of the sensor. It is also practical in wearable human respiratory signal detection equipment. In summary, the flexible inductance pressure sensor designed in this study has high performance and practicability in the application of wearable electronic devices, which is of great significance to the development of actual wearable electronic devices.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于可穿戴电子设备的柔性电感压力传感器
目前,可穿戴设备对基于环境适应性的柔性传感器提出了更高的要求。因此,为了解决电流柔性传感器灵敏度低的问题,在传统的柔性传感器中引入高磁导率的铁氧体薄膜,提出了一种新型的柔性电感式压力传感器。通过研究验证了该方法的有效性和实用性。结果表明,理论预测的相关曲线与实际曲线呈现相同的趋势。传感器A的灵敏度最高,为1.61 kPa−1;在不同弯曲条件下,灵敏度差异为0 ~ 0.20。当实际外压从0增加到13.6 Pa时,电感的实际变化约为0.88%。当激励电压为0.5 V时,传感器A的实际电感输出值由初始的13.22 μ H增加到13.26 μ H,实际变化率小于0.30%。在可穿戴设备的应用中,可穿戴电子键盘的按键具有最大输出电压变化值,大于0.15 V,提高了传感器的高稳定性和实用性。在可穿戴式人体呼吸信号检测设备中也具有实用性。综上所述,本研究设计的柔性电感式压力传感器在可穿戴电子设备中的应用具有较高的性能和实用性,对实际可穿戴电子设备的开发具有重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Nanoelectronics and Optoelectronics
Journal of Nanoelectronics and Optoelectronics 工程技术-工程:电子与电气
自引率
16.70%
发文量
48
审稿时长
12.5 months
期刊最新文献
Pulsed Optoelectronic Rangefinder and Its Measurement Applications in Architectural Design Rationality Assessment Electrochemical Micro-Reaction and Failure Mechanism of New Materials Used at Low Temperature in Coastal Environment Ultrawideband Tunable Polarization Converter Based on Metamaterials Nanofluid Heat Transfer and Flow Characteristics in a Convex Plate Heat Exchanger Based on Multi-Objective Optimization Characterization of ZnO/rGO Nanocomposite and Its Application for Photocatalytic Degradation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1