Analysis of Polycyclic Aromatic Hydrocarbons Using Magnetic Three-Dimensional Graphene Solid-Phase Extraction Coupled with Gas Chromatography–Mass Spectrometry
{"title":"Analysis of Polycyclic Aromatic Hydrocarbons Using Magnetic Three-Dimensional Graphene Solid-Phase Extraction Coupled with Gas Chromatography–Mass Spectrometry","authors":"Hassan Sereshti, Mahsa Karimi, Sajad Karami, Shokouh Mahpishanian, Mehdi Esmaeili Bidhendi, Shahabaldin Rezania, Amin Mojiri, Hesam Kamyab, Hamid Rashidi Nodeh","doi":"10.3390/separations10110564","DOIUrl":null,"url":null,"abstract":"In this study, a composite material consisting of three-dimensional graphene aerogel and iron oxide nanoparticles (3DG/Fe3O4) was created and utilized for the purpose of magnetic solid-phase extraction (MSPE) of thirteen polycyclic aromatic hydrocarbon (PAH) compounds via gas chromatography–mass spectrometry/selected ion monitoring (GC-MS/SIM) analysis. The synthesized adsorbent underwent a range of characterization techniques, including scanning electron microscopy, vibrating sample magnetometry, Raman spectroscopy, X-ray diffraction, Brunauer–Emmett–Teller, Fourier transform-infrared spectroscopy, and Barrett–Joyner–Halenda techniques, to examine its properties and morphology. The synthesized adsorbent integrates the benefits of superior adsorption capacity from modified graphene oxide (GO) with the magnetic separability of magnetite microparticles, resulting in a high adsorption capacity with easy separation from sample solutions. The efficiency of the proposed method was optimized and modeled using a central composite design (CCD), which considered the primary factors influencing it. The optimal conditions were obtained as the adsorbent dosage of 10 mg, the extraction time of 4 min, and the salt concentration of 3% w/v. The limit of detection for the target PAHs was established to range from 0.016 to 0.2 ng mL−1 in optimal conditions, exhibiting a signal-to-noise ratio of 3. The linear dynamic range spanned from 5 to 100 ng mL−1, with determination coefficients (R2) ranging from 0.9913 to 0.9997. The intra- and inter-day precisions were calculated as relative standard deviations (RSDs) equal to 3.9% and 4.7%, respectively. The proposed method was successfully applied to the determination of PAHs in water samples (tap, river, and rainwater), and recoveries in the range of 71–110% (RSDs < 5.2%, n = 3) were obtained.","PeriodicalId":21833,"journal":{"name":"Separations","volume":" January","pages":"0"},"PeriodicalIF":2.5000,"publicationDate":"2023-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Separations","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/separations10110564","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
In this study, a composite material consisting of three-dimensional graphene aerogel and iron oxide nanoparticles (3DG/Fe3O4) was created and utilized for the purpose of magnetic solid-phase extraction (MSPE) of thirteen polycyclic aromatic hydrocarbon (PAH) compounds via gas chromatography–mass spectrometry/selected ion monitoring (GC-MS/SIM) analysis. The synthesized adsorbent underwent a range of characterization techniques, including scanning electron microscopy, vibrating sample magnetometry, Raman spectroscopy, X-ray diffraction, Brunauer–Emmett–Teller, Fourier transform-infrared spectroscopy, and Barrett–Joyner–Halenda techniques, to examine its properties and morphology. The synthesized adsorbent integrates the benefits of superior adsorption capacity from modified graphene oxide (GO) with the magnetic separability of magnetite microparticles, resulting in a high adsorption capacity with easy separation from sample solutions. The efficiency of the proposed method was optimized and modeled using a central composite design (CCD), which considered the primary factors influencing it. The optimal conditions were obtained as the adsorbent dosage of 10 mg, the extraction time of 4 min, and the salt concentration of 3% w/v. The limit of detection for the target PAHs was established to range from 0.016 to 0.2 ng mL−1 in optimal conditions, exhibiting a signal-to-noise ratio of 3. The linear dynamic range spanned from 5 to 100 ng mL−1, with determination coefficients (R2) ranging from 0.9913 to 0.9997. The intra- and inter-day precisions were calculated as relative standard deviations (RSDs) equal to 3.9% and 4.7%, respectively. The proposed method was successfully applied to the determination of PAHs in water samples (tap, river, and rainwater), and recoveries in the range of 71–110% (RSDs < 5.2%, n = 3) were obtained.
期刊介绍:
Separations (formerly Chromatography, ISSN 2227-9075, CODEN: CHROBV) provides an advanced forum for separation and purification science and technology in all areas of chemical, biological and physical science. It publishes reviews, regular research papers and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. There are, in addition, unique features of this journal:
Manuscripts regarding research proposals and research ideas will be particularly welcomed.
Electronic files and software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material.
Manuscripts concerning summaries and surveys on research cooperation and projects (that are funded by national governments) to give information for a broad field of users.
The scope of the journal includes but is not limited to:
Theory and methodology (theory of separation methods, sample preparation, instrumental and column developments, new separation methodologies, etc.)
Equipment and techniques, novel hyphenated analytical solutions (significantly extended by their combination with spectroscopic methods and in particular, mass spectrometry)
Novel analysis approaches and applications to solve analytical challenges which utilize chromatographic separations as a key step in the overall solution
Computational modelling of separations for the purpose of fundamental understanding and/or chromatographic optimization