Image and Velocity Profile Reconstruction Using a Customized 8–16 Electrode Electrical Capacitance Tomography Sensor Based on LabVIEW Simulation

IF 0.6 4区 工程技术 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC Journal of Nanoelectronics and Optoelectronics Pub Date : 2023-06-01 DOI:10.1166/jno.2023.3423
Sidi M. Ahmed Ghaly, M. Y. Shalaby, Khaled Al-Snaie, Majdi Oraiqat, Mohammad O. Khan
{"title":"Image and Velocity Profile Reconstruction Using a Customized 8–16 Electrode Electrical Capacitance Tomography Sensor Based on LabVIEW Simulation","authors":"Sidi M. Ahmed Ghaly, M. Y. Shalaby, Khaled Al-Snaie, Majdi Oraiqat, Mohammad O. Khan","doi":"10.1166/jno.2023.3423","DOIUrl":null,"url":null,"abstract":"Electrical Capacitance Tomography is a method for determining the dielectric permittivity distribution inside an object from the measurement of the external capacitances of a multi-electrode assembly. The measuring electrodes, which are metal plates, must be large enough to give a measurable change in capacitance. In this article, the performance of the ECT sensor, the sensitivity matrix, and hence the reconstructed image quality and the velocity profiles are improved. A typical customized 16–8 electrode ECT sensor is proposed, simulated, and implemented on the LabVIEW platform in contrast with a set of standard 8, 12, and 16-electrode ECT sensors. The results of these types of sensors are noted and compared to each other, focusing on the customized sensor. It is observed from the results obtained during this simulation experiment that the performance of the customized 16–8 electrode ECT sensor is comparatively better and exhibits better quality and performance with respect to its image and velocity reconstruction. The comparison of results further demonstrated that the correlation coefficient changes from 0.61 to 0.96, and the error images are within 0.3 to 0.1 for the SNRs going from 60 to 90 dB. It was also observed that the reconstructed velocity profiles are consistent with the original expected velocity profiles for the customized 8–16-electrode ECT sensor.","PeriodicalId":16446,"journal":{"name":"Journal of Nanoelectronics and Optoelectronics","volume":"5 1","pages":"0"},"PeriodicalIF":0.6000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nanoelectronics and Optoelectronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1166/jno.2023.3423","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 1

Abstract

Electrical Capacitance Tomography is a method for determining the dielectric permittivity distribution inside an object from the measurement of the external capacitances of a multi-electrode assembly. The measuring electrodes, which are metal plates, must be large enough to give a measurable change in capacitance. In this article, the performance of the ECT sensor, the sensitivity matrix, and hence the reconstructed image quality and the velocity profiles are improved. A typical customized 16–8 electrode ECT sensor is proposed, simulated, and implemented on the LabVIEW platform in contrast with a set of standard 8, 12, and 16-electrode ECT sensors. The results of these types of sensors are noted and compared to each other, focusing on the customized sensor. It is observed from the results obtained during this simulation experiment that the performance of the customized 16–8 electrode ECT sensor is comparatively better and exhibits better quality and performance with respect to its image and velocity reconstruction. The comparison of results further demonstrated that the correlation coefficient changes from 0.61 to 0.96, and the error images are within 0.3 to 0.1 for the SNRs going from 60 to 90 dB. It was also observed that the reconstructed velocity profiles are consistent with the original expected velocity profiles for the customized 8–16-electrode ECT sensor.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于LabVIEW仿真的自定义8-16电极电容层析成像传感器图像和速度剖面重建
电容层析成像是一种通过测量多电极组件的外部电容来确定物体内部介电常数分布的方法。测量电极是金属板,必须足够大,以产生可测量的电容变化。在本文中,改进了ECT传感器的性能、灵敏度矩阵,从而改进了重建图像的质量和速度分布。在LabVIEW平台上提出了一种典型的定制16-8电极ECT传感器,并对其进行了仿真和实现,与一组标准的8、12和16电极ECT传感器进行了对比。这些类型的传感器的结果被记录并相互比较,重点是定制传感器。从本次仿真实验的结果可以看出,定制的16-8电极ECT传感器的性能相对较好,在图像和速度重建方面表现出更好的质量和性能。对比结果进一步表明,在60 ~ 90 dB信噪比范围内,相关系数在0.61 ~ 0.96之间变化,误差在0.3 ~ 0.1之间。重建的速度分布与定制的8 - 16电极ECT传感器的原始预期速度分布一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Nanoelectronics and Optoelectronics
Journal of Nanoelectronics and Optoelectronics 工程技术-工程:电子与电气
自引率
16.70%
发文量
48
审稿时长
12.5 months
期刊最新文献
Pulsed Optoelectronic Rangefinder and Its Measurement Applications in Architectural Design Rationality Assessment Electrochemical Micro-Reaction and Failure Mechanism of New Materials Used at Low Temperature in Coastal Environment Ultrawideband Tunable Polarization Converter Based on Metamaterials Nanofluid Heat Transfer and Flow Characteristics in a Convex Plate Heat Exchanger Based on Multi-Objective Optimization Characterization of ZnO/rGO Nanocomposite and Its Application for Photocatalytic Degradation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1