ANALISIS STRUKTUR BANGUNAN HOTEL 17 LANTAI DAERAH KEMAYORAN JAKARTA DENGAN PERMODELAN 3D SOFTWARE SAP2000

Q1 Multidisciplinary Citizen Science Theory and Practice Pub Date : 2023-05-23 DOI:10.53866/jimi.v3i2.237
Andrean Prasetiyo, Endah Kanti Pangestuti
{"title":"ANALISIS STRUKTUR BANGUNAN HOTEL 17 LANTAI DAERAH KEMAYORAN JAKARTA DENGAN PERMODELAN 3D SOFTWARE SAP2000","authors":"Andrean Prasetiyo, Endah Kanti Pangestuti","doi":"10.53866/jimi.v3i2.237","DOIUrl":null,"url":null,"abstract":"There are lots of skyscrapers in Indonesia, especially in the Jakarta area. In designing the building, of course, it needs to be designed with appropriate earthquake loads for the location and conditions around the building. Regulations that can be used in the design of skyscrapers are regulations developed by the Indonesian National Standard (SNI), including earthquake loads, gravity loads, and design standards. The method of collecting data in research includes 2 things, namely, (1). primary data, in the form of style output in the SAP2000 version 20 application, Spcolumn v.6.0 column interaction diagrams, and the results of Microsoft Excel calculation analysis. (2) the secondary data obtained is in the form of an image of the structure of the 17 Floor Hotel Kemayoran Area Building.Secondary and primary data processing is in the form of remodeling the redesigned building structure design in SAP2000 version 20 and Spcoloumn v.6.0, determining the seismic design category, analyzing and making changes to the original building structure design that are not in accordance with SNI 1726: 2019 and SNI 2847: 2019. The results of the study found differences in the year versions in SNI 2847:2013 and 2847:2019, SNI 1726:2012 and SNI 1726:2019. In SNI 2847:2019 concerning structural concrete there is a change or addition of special detailing and stirrup reinforcement in columns, beams and floor slabs, while in SNI 1726:2019 concerning earthquake loads there is an increase in seismic forces.","PeriodicalId":32270,"journal":{"name":"Citizen Science Theory and Practice","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Citizen Science Theory and Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53866/jimi.v3i2.237","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Multidisciplinary","Score":null,"Total":0}
引用次数: 0

Abstract

There are lots of skyscrapers in Indonesia, especially in the Jakarta area. In designing the building, of course, it needs to be designed with appropriate earthquake loads for the location and conditions around the building. Regulations that can be used in the design of skyscrapers are regulations developed by the Indonesian National Standard (SNI), including earthquake loads, gravity loads, and design standards. The method of collecting data in research includes 2 things, namely, (1). primary data, in the form of style output in the SAP2000 version 20 application, Spcolumn v.6.0 column interaction diagrams, and the results of Microsoft Excel calculation analysis. (2) the secondary data obtained is in the form of an image of the structure of the 17 Floor Hotel Kemayoran Area Building.Secondary and primary data processing is in the form of remodeling the redesigned building structure design in SAP2000 version 20 and Spcoloumn v.6.0, determining the seismic design category, analyzing and making changes to the original building structure design that are not in accordance with SNI 1726: 2019 and SNI 2847: 2019. The results of the study found differences in the year versions in SNI 2847:2013 and 2847:2019, SNI 1726:2012 and SNI 1726:2019. In SNI 2847:2019 concerning structural concrete there is a change or addition of special detailing and stirrup reinforcement in columns, beams and floor slabs, while in SNI 1726:2019 concerning earthquake loads there is an increase in seismic forces.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用三维建模软件 SAP2000 对雅加达 KEMAYORAN 地区 17 层酒店建筑进行结构分析
印尼有很多摩天大楼,尤其是在雅加达地区。当然,在设计建筑物时,需要根据建筑物周围的位置和条件进行适当的地震荷载设计。可用于摩天大楼设计的法规是由印度尼西亚国家标准(SNI)制定的法规,包括地震荷载、重力荷载和设计标准。研究中收集数据的方法包括两方面,即:(1)原始数据,以SAP2000 version 20应用程序的样式输出形式,Spcolumn v.6.0列交互图形式,以及Microsoft Excel计算分析结果。(2)获得的二次数据为17层Hotel Kemayoran Area Building的结构图像。二次和一次数据处理的形式是对SAP2000 version 20和spcolumn v.6.0中重新设计的建筑结构设计进行改造,确定抗震设计类别,对不符合SNI 1726: 2019和SNI 2847: 2019的原有建筑结构设计进行分析和修改。研究结果发现,SNI 2847:2013和2847:2019、SNI 1726:2012和SNI 1726:2019的年份版本存在差异。在SNI 2847:2019中,有关结构混凝土的规定改变或增加了柱、梁和楼板的特殊细节和箍筋加固,而在SNI 1726:2019中,有关地震荷载的规定增加了地震力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Citizen Science Theory and Practice
Citizen Science Theory and Practice Multidisciplinary-Multidisciplinary
CiteScore
4.70
自引率
0.00%
发文量
25
审稿时长
45 weeks
期刊最新文献
Snap Decisions: Assessing Participation and Data Quality in a Citizen Science Program Using Repeat Photography Diversifying Large-Scale Participatory Science: The Efficacy of Engagement through Facilitator Organizations “Every Small Action Helps Towards the Greater Cause:” Online Communities Scaling Up Online Community-Led Citizen Science in Addressing Litter Challenges in Scotland Cross-Project Analysis of Volunteers’ Scientific Observation Skills Citizen Scientist Participation in Research on Private Lands Positively Impacts Multiple Conservation Behaviors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1