Wearable Accelerometer and Gyroscope Sensors for Estimating the Severity of Essential Tremor

IF 3.7 3区 医学 Q2 ENGINEERING, BIOMEDICAL IEEE Journal of Translational Engineering in Health and Medicine-Jtehm Pub Date : 2023-11-01 DOI:10.1109/JTEHM.2023.3329344
Sheik Mohammed Ali;Sridhar Poosapadi Arjunan;James Peter;Laura Perju-Dumbrava;Catherine Ding;Michael Eller;Sanjay Raghav;Peter Kempster;Mohammod Abdul Motin;P. J. Radcliffe;Dinesh Kant Kumar
{"title":"Wearable Accelerometer and Gyroscope Sensors for Estimating the Severity of Essential Tremor","authors":"Sheik Mohammed Ali;Sridhar Poosapadi Arjunan;James Peter;Laura Perju-Dumbrava;Catherine Ding;Michael Eller;Sanjay Raghav;Peter Kempster;Mohammod Abdul Motin;P. J. Radcliffe;Dinesh Kant Kumar","doi":"10.1109/JTEHM.2023.3329344","DOIUrl":null,"url":null,"abstract":"Background: Several validated clinical scales measure the severity of essential tremor (ET). Their assessments are subjective and can depend on familiarity and training with scoring systems. Method: We propose a multi-modal sensing using a wearable inertial measurement unit for estimating scores on the Fahn-Tolosa-Marin tremor rating scale (FTM) and determine the classification accuracy within the tremor type. 17 ET participants and 18 healthy controls were recruited for the study. Two movement disorder neurologists who were blinded to prior clinical information viewed video recordings and scored the FTM. Participants drew a guided Archimedes spiral while wearing an inertial measurement unit placed at the mid-point between the lateral epicondyle of the humerus and the anatomical snuff box. Acceleration and gyroscope recordings were analyzed. The ratio of the power spectral density between frequency bands 0.5-4 Hz and 4–12 Hz, and the sum of power spectrum density over the entire spectrum of 2–74 Hz, for both accelerometer and gyroscope data, were computed. FTM was estimated using regression model and classification using SVM was validated using the leave-one-out method. Results: Regression analysis showed a moderate to good correlation when individual features were used, while correlation was high (\n<inline-formula> <tex-math>$r^{2}$ </tex-math></inline-formula>\n = 0.818) when suitable features of the gyro and accelerometer were combined. The accuracy for two-class classification of the combined features using SVM was 91.42% while for four-class it was 68.57%. Conclusion: Potential applications of this novel wearable sensing method using a wearable Inertial Measurement Unit (IMU) include monitoring of ET and clinical trials of new treatments for the disorder.","PeriodicalId":54255,"journal":{"name":"IEEE Journal of Translational Engineering in Health and Medicine-Jtehm","volume":"12 ","pages":"194-203"},"PeriodicalIF":3.7000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10304233","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal of Translational Engineering in Health and Medicine-Jtehm","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10304233/","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Several validated clinical scales measure the severity of essential tremor (ET). Their assessments are subjective and can depend on familiarity and training with scoring systems. Method: We propose a multi-modal sensing using a wearable inertial measurement unit for estimating scores on the Fahn-Tolosa-Marin tremor rating scale (FTM) and determine the classification accuracy within the tremor type. 17 ET participants and 18 healthy controls were recruited for the study. Two movement disorder neurologists who were blinded to prior clinical information viewed video recordings and scored the FTM. Participants drew a guided Archimedes spiral while wearing an inertial measurement unit placed at the mid-point between the lateral epicondyle of the humerus and the anatomical snuff box. Acceleration and gyroscope recordings were analyzed. The ratio of the power spectral density between frequency bands 0.5-4 Hz and 4–12 Hz, and the sum of power spectrum density over the entire spectrum of 2–74 Hz, for both accelerometer and gyroscope data, were computed. FTM was estimated using regression model and classification using SVM was validated using the leave-one-out method. Results: Regression analysis showed a moderate to good correlation when individual features were used, while correlation was high ( $r^{2}$ = 0.818) when suitable features of the gyro and accelerometer were combined. The accuracy for two-class classification of the combined features using SVM was 91.42% while for four-class it was 68.57%. Conclusion: Potential applications of this novel wearable sensing method using a wearable Inertial Measurement Unit (IMU) include monitoring of ET and clinical trials of new treatments for the disorder.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于估计特发性震颤严重程度的可穿戴加速度计和陀螺仪传感器
背景:有几种有效的临床量表可以测量本质性震颤(ET)的严重程度。其评估是主观的,可能取决于对评分系统的熟悉程度和培训情况。方法:我们提出了一种使用可穿戴惯性测量装置的多模态传感方法,用于估算法恩-托洛萨-马林震颤评分量表(FTM)的分数,并确定震颤类型分类的准确性。研究招募了 17 名 ET 参与者和 18 名健康对照者。两名运动障碍神经学家在对之前的临床信息保密的情况下观看录像并对 FTM 进行评分。参与者佩戴惯性测量装置,在肱骨外上髁与解剖鼻烟盒之间的中点绘制阿基米德螺旋线。对加速度和陀螺仪记录进行了分析。计算了加速度计和陀螺仪数据在 0.5-4 Hz 和 4-12 Hz 频段之间的功率谱密度比,以及 2-74 Hz 整个频谱的功率谱密度总和。使用回归模型估算了 FTM,并使用留一法验证了使用 SVM 进行的分类。结果显示回归分析表明,当使用单个特征时,相关性为中等到良好,而当陀螺仪和加速度计的合适特征组合在一起时,相关性很高($r^{2}$ = 0.818)。使用 SVM 对组合特征进行两级分类的准确率为 91.42%,而四级分类的准确率为 68.57%。结论这种使用可穿戴惯性测量单元(IMU)的新型可穿戴传感方法的潜在应用包括监测 ET 和对该疾病的新疗法进行临床试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.40
自引率
2.90%
发文量
65
审稿时长
27 weeks
期刊介绍: The IEEE Journal of Translational Engineering in Health and Medicine is an open access product that bridges the engineering and clinical worlds, focusing on detailed descriptions of advanced technical solutions to a clinical need along with clinical results and healthcare relevance. The journal provides a platform for state-of-the-art technology directions in the interdisciplinary field of biomedical engineering, embracing engineering, life sciences and medicine. A unique aspect of the journal is its ability to foster a collaboration between physicians and engineers for presenting broad and compelling real world technological and engineering solutions that can be implemented in the interest of improving quality of patient care and treatment outcomes, thereby reducing costs and improving efficiency. The journal provides an active forum for clinical research and relevant state-of the-art technology for members of all the IEEE societies that have an interest in biomedical engineering as well as reaching out directly to physicians and the medical community through the American Medical Association (AMA) and other clinical societies. The scope of the journal includes, but is not limited, to topics on: Medical devices, healthcare delivery systems, global healthcare initiatives, and ICT based services; Technological relevance to healthcare cost reduction; Technology affecting healthcare management, decision-making, and policy; Advanced technical work that is applied to solving specific clinical needs.
期刊最新文献
A Multi-Task Based Deep Learning Framework With Landmark Detection for MRI Couinaud Segmentation Video-Based Respiratory Rate Estimation for Infants in the NICU A Novel Chest-Based PPG Measurement System Integrating Multimodal Neuroimaging and Genetics: A Structurally-Linked Sparse Canonical Correlation Analysis Approach A Pre-Voiding Alarm System Using Wearable Ultrasound and Machine Learning Algorithms for Children With Nocturnal Enuresis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1