Clarification upsets and ion exchange resin symptoms due to design

Zuckerindustrie Pub Date : 2023-10-01 DOI:10.36961/si30505
Patrick L. Coterillo
{"title":"Clarification upsets and ion exchange resin symptoms due to design","authors":"Patrick L. Coterillo","doi":"10.36961/si30505","DOIUrl":null,"url":null,"abstract":"Abstract: Ion exchange resin (IER) decolorization columns face challenges because of upstream process upsets and certain design choices. Some of these challenges have been caused by excessive amounts of calcium carbonate carried over from press filtration to the IER columns. As a result, the columns experience sudden impacts on performance, which causes a premature shutdown or retention of the calcium carbonate, degrading resin performance over time. In addition, the refinery suffers in terms of overall throughput due to pressure drop in the IER columns or reduced decolorization and higher amount wash syrup in the centrifuges. Fiber glass nozzles installed in the columns have been replaced with stainless steel nozzles. Pros and cons of the replacement are discussed, which resulted in a much longer service life of the nozzles.","PeriodicalId":24046,"journal":{"name":"Zuckerindustrie","volume":"90 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zuckerindustrie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36961/si30505","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract: Ion exchange resin (IER) decolorization columns face challenges because of upstream process upsets and certain design choices. Some of these challenges have been caused by excessive amounts of calcium carbonate carried over from press filtration to the IER columns. As a result, the columns experience sudden impacts on performance, which causes a premature shutdown or retention of the calcium carbonate, degrading resin performance over time. In addition, the refinery suffers in terms of overall throughput due to pressure drop in the IER columns or reduced decolorization and higher amount wash syrup in the centrifuges. Fiber glass nozzles installed in the columns have been replaced with stainless steel nozzles. Pros and cons of the replacement are discussed, which resulted in a much longer service life of the nozzles.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
澄清混乱和离子交换树脂症状由于设计
摘要离子交换树脂(IER)脱色柱由于上游工艺的干扰和某些设计选择而面临挑战。其中一些挑战是由过量的碳酸钙从压滤柱携带到IER柱造成的。因此,色谱柱的性能会受到突然的影响,这会导致碳酸钙过早关闭或滞留,随着时间的推移降低树脂性能。此外,由于IER塔中压力下降或离心机中脱色减少和洗涤糖浆量增加,炼油厂在总体吞吐量方面受到影响。柱上安装的玻璃纤维喷嘴已被不锈钢喷嘴取代。讨论了更换的利弊,从而延长了喷嘴的使用寿命。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Reducing boiler maintenance costs with improved materials for air-heater tubes Utilization of bagasse as a soil amendment in sugarcane production on mineral soils in Florida Process optimization and reduction of production costs in modern beet sugar manufacturing Clarification upsets and ion exchange resin symptoms due to design Controlled-release urea for use in sugarcane ratoons
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1