Fully Automated Coronary Artery Calcium Quantification on ECG-gated Non-contrast Cardiac CT Using Deep-learning with Novel Heart-labeling Method

Daigo Takahashi, Shinichiro Fujimoto, Yui O Nozaki, Ayako Kudo, Yuko O Kawaguchi, Kazuhisa Takamura, Makoto Hiki, Eisuke Sato, Nobuo Tomizawa, Hiroyuki Daida, Tohru Minamino
{"title":"Fully Automated Coronary Artery Calcium Quantification on ECG-gated Non-contrast Cardiac CT Using Deep-learning with Novel Heart-labeling Method","authors":"Daigo Takahashi, Shinichiro Fujimoto, Yui O Nozaki, Ayako Kudo, Yuko O Kawaguchi, Kazuhisa Takamura, Makoto Hiki, Eisuke Sato, Nobuo Tomizawa, Hiroyuki Daida, Tohru Minamino","doi":"10.1093/ehjopen/oead113","DOIUrl":null,"url":null,"abstract":"Abstract Aims To develop an artificial intelligence (AI)-model which enables fully automated accurate quantification of coronary artery calcium (CAC), using deep learning (DL) on electrocardiogram (ECG)-gated non-contrast cardiac computed tomography (gated CCT) images. Methods and Results Retrospectively, 560 gated CCT images (including 60 synthetic images) performed at our institution were used to train AI-model, which can automatically divide heart region into 5 areas belonging to left main (LM), left anterior descending (LAD), circumflex (LCX), right coronary artery (RCA), and other. Total and vessel-specific CAC score (CACS) in each scan were manually evaluated. AI-model was trained with novel Heart-labeling method via DL according to the manual-derived results. Then, another 409 gated CCT images obtained in our institution were used for model validation. The performance of present AI-model was tested using another external cohort of 400 gated CCT images of Stanford Center for Artificial Intelligence of Medical Imaging by comparing with the ground truth. The overall accuracy of the AI-model for total CACS classification was excellent with Cohen’s kappa of k=0.89 and 0.95 (validation and test, respectively), which surpasses previous research of k=0.89. Bland-Altman analysis showed little difference in individual total and vessel-specific CACS between AI-derived CACS and ground truth in test cohort (mean difference [95% confidence interval] were 1.5 [-42.6, 45.6], -1.5 [-100.5, 97.5], 6.6 [-60.2, 73.5], 0.96 [-59.2, 61.1], and 7.6[-134.1, 149.2] for LM, LAD, LCX, RCA, and total CACS, respectively). Conclusion Present Heart-labeling method provides a further improvement in fully automated, total and vessel-specific CAC quantification on gated CCT.","PeriodicalId":93995,"journal":{"name":"European heart journal open","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European heart journal open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjopen/oead113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Aims To develop an artificial intelligence (AI)-model which enables fully automated accurate quantification of coronary artery calcium (CAC), using deep learning (DL) on electrocardiogram (ECG)-gated non-contrast cardiac computed tomography (gated CCT) images. Methods and Results Retrospectively, 560 gated CCT images (including 60 synthetic images) performed at our institution were used to train AI-model, which can automatically divide heart region into 5 areas belonging to left main (LM), left anterior descending (LAD), circumflex (LCX), right coronary artery (RCA), and other. Total and vessel-specific CAC score (CACS) in each scan were manually evaluated. AI-model was trained with novel Heart-labeling method via DL according to the manual-derived results. Then, another 409 gated CCT images obtained in our institution were used for model validation. The performance of present AI-model was tested using another external cohort of 400 gated CCT images of Stanford Center for Artificial Intelligence of Medical Imaging by comparing with the ground truth. The overall accuracy of the AI-model for total CACS classification was excellent with Cohen’s kappa of k=0.89 and 0.95 (validation and test, respectively), which surpasses previous research of k=0.89. Bland-Altman analysis showed little difference in individual total and vessel-specific CACS between AI-derived CACS and ground truth in test cohort (mean difference [95% confidence interval] were 1.5 [-42.6, 45.6], -1.5 [-100.5, 97.5], 6.6 [-60.2, 73.5], 0.96 [-59.2, 61.1], and 7.6[-134.1, 149.2] for LM, LAD, LCX, RCA, and total CACS, respectively). Conclusion Present Heart-labeling method provides a further improvement in fully automated, total and vessel-specific CAC quantification on gated CCT.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于深度学习和新型心脏标记方法的心电图门控非对比心脏CT全自动冠状动脉钙定量
摘要:目的开发一种人工智能(AI)模型,利用对心电图(ECG)门控非对比心脏计算机断层扫描(门控CCT)图像的深度学习(DL),实现冠状动脉钙(CAC)的全自动准确定量。方法与结果回顾性利用我院拍摄的560张门控CCT图像(其中包括60张合成图像)训练ai模型,该模型可自动将心脏区域划分为左主干(LM)、左前降支(LAD)、旋支(LCX)、右冠状动脉(RCA)等5个区域。人工评估每次扫描的总CAC评分和血管特异性CAC评分(CACS)。根据人工生成的结果,采用DL方法对人工智能模型进行训练。然后,使用我们机构获得的另外409张门控CCT图像进行模型验证。使用斯坦福医学成像人工智能中心的400张门控CCT图像作为另一个外部队列,通过与ground truth进行比较,对本ai模型的性能进行了测试。ai模型对总CACS分类的总体准确率非常好,Cohen的kappa为k=0.89和0.95(分别为验证和检验),超过了以往研究的k=0.89。Bland-Altman分析显示,人工智能获得的个体总CACS和血管特异性CACS与试验队列中基本真实值差异不大(LM、LAD、LCX、RCA和总CACS的平均差异[95%置信区间]分别为1.5[-42.6,45.6]、-1.5[-100.5,97.5]、6.6[-60.2,73.5]、0.96[-59.2,61.1]和7.6[-134.1,149.2])。结论本方法进一步提高了门控CCT的全自动、全血管特异性CAC定量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.80
自引率
0.00%
发文量
0
期刊最新文献
The incidence of atrial fibrillation detected by implantable loop recorders: a comparison between patients with and without embolic stroke of undetermined source. Intra-individual variability in lipoprotein(a): the value of a repeat measure for reclassifying individuals at intermediate risk. New data allow to better understand the secrets of lipoprotein(a): is that for sure? Correction to: Correlates and consequences of atrial fibrillation in a prospective study of 25 000 participants in the China Kadoorie Biobank. Colchicine for cardiovascular and limb risk reduction in Medicare beneficiaries with peripheral artery disease: emulation of target trials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1