Study of the influence of the parameters of modern grounding wires on the value of power losses in them for overhead power lines of 330-750 kV

IF 1.6 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC Electrical Engineering & Electromechanics Pub Date : 2023-10-21 DOI:10.20998/2074-272x.2023.6.14
A. V. Krasnozhon, A. O. Kvytsynskyi, R. O. Buinyi, I. V. Dihtyaruk, O. V. Krasnozhon
{"title":"Study of the influence of the parameters of modern grounding wires on the value of power losses in them for overhead power lines of 330-750 kV","authors":"A. V. Krasnozhon, A. O. Kvytsynskyi, R. O. Buinyi, I. V. Dihtyaruk, O. V. Krasnozhon","doi":"10.20998/2074-272x.2023.6.14","DOIUrl":null,"url":null,"abstract":"Introduction. The problem of estimating power losses in grounding wires with built-in fiber optic cable for overhead power lines of voltage class 330-750 kV is relevant, while it is obvious that the amount of losses depends on the chosen brand of wire. Problem. In the article, an analysis of the influence of the parameters of grounding wires on the amount of losses that occur in them in the normal mode of operation of the overhead power lines is carried out. Goal. The purpose of the work is to determine the criterion for the selection of grounding wires with a built-in optical fiber cable under the condition of increasing the energy efficiency of electricity transmission. Methodology. To calculate power losses in grounding wires, the methods of electromagnetic field theory were used, while taking into account the location of phase conductors on various types of towers of operating 330-750 kV overhead power lines and the possible current load of such lines. Results. The paper analyzed the dependence of losses in the grounding wires of the overhead power lines on the ratio of its active and reactive resistances, determined in which range of this ratio the losses will be close to the maximum. It is shown that the amount of specific power losses in the grounding wires of 330-750 kV overhead power lines in its normal operating modes can range from 1.6 kW/km for the 750 kV lines to hundreds of W/km for the 330 kV power lines. Originality. For the first time, it is recommended to use grounding wires with built-in fiber optic cable with running active resistance in the range of no more than 0.25 Ohm/km, which will minimize power losses and increase the energy efficiency of the 330-750 kV overhead power lines. Practical value. The obtained results can be applied at the stage of designing new or modernizing existing overhead power lines in order to reduce losses and increase the energy efficiency of lines.","PeriodicalId":44198,"journal":{"name":"Electrical Engineering & Electromechanics","volume":"11 5","pages":"0"},"PeriodicalIF":1.6000,"publicationDate":"2023-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Engineering & Electromechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20998/2074-272x.2023.6.14","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 1

Abstract

Introduction. The problem of estimating power losses in grounding wires with built-in fiber optic cable for overhead power lines of voltage class 330-750 kV is relevant, while it is obvious that the amount of losses depends on the chosen brand of wire. Problem. In the article, an analysis of the influence of the parameters of grounding wires on the amount of losses that occur in them in the normal mode of operation of the overhead power lines is carried out. Goal. The purpose of the work is to determine the criterion for the selection of grounding wires with a built-in optical fiber cable under the condition of increasing the energy efficiency of electricity transmission. Methodology. To calculate power losses in grounding wires, the methods of electromagnetic field theory were used, while taking into account the location of phase conductors on various types of towers of operating 330-750 kV overhead power lines and the possible current load of such lines. Results. The paper analyzed the dependence of losses in the grounding wires of the overhead power lines on the ratio of its active and reactive resistances, determined in which range of this ratio the losses will be close to the maximum. It is shown that the amount of specific power losses in the grounding wires of 330-750 kV overhead power lines in its normal operating modes can range from 1.6 kW/km for the 750 kV lines to hundreds of W/km for the 330 kV power lines. Originality. For the first time, it is recommended to use grounding wires with built-in fiber optic cable with running active resistance in the range of no more than 0.25 Ohm/km, which will minimize power losses and increase the energy efficiency of the 330-750 kV overhead power lines. Practical value. The obtained results can be applied at the stage of designing new or modernizing existing overhead power lines in order to reduce losses and increase the energy efficiency of lines.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
330 ~ 750kv架空线路现代接地线参数对接地线损耗值的影响研究
介绍。对于电压等级为330- 750kv的架空电力线路,使用内置光纤电缆估算接地线的功率损耗问题是相关的,但显然损耗的大小取决于所选择的电线品牌。问题。分析了架空电力线路在正常运行状态下,接地线参数对接地线损耗量的影响。的目标。本工作的目的是在提高电力传输能效的条件下,确定内置光纤电缆接地导线的选择标准。方法。在考虑330 ~ 750kv架空线路运行时各塔架上相导体位置及架空线路可能的电流负荷的情况下,采用电磁场理论的方法计算接地线的功率损耗。结果。分析了架空电力线路接地线的损耗与其有功电阻和无功电阻的比值的关系,确定了在该比值的哪个范围内接地线的损耗接近最大值。结果表明,330- 750kv架空输电线路在正常运行模式下,接地线的比功率损耗从750kv线路的1.6 kW/km到330 kV线路的数百W/km不等。创意。首次使用时,建议使用内置光缆的接地线,运行有源电阻不大于0.25欧姆/公里,这样可以最大限度地减少功率损耗,提高330 ~ 750kv架空线路的能效。实用价值。所得结果可应用于设计新的或现代化现有架空电力线路,以减少损耗和提高线路的能源效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Electrical Engineering & Electromechanics
Electrical Engineering & Electromechanics ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
2.40
自引率
50.00%
发文量
53
审稿时长
10 weeks
期刊最新文献
The mutual influence of exciting and induced currents in the circular solenoid – massive conductor system Current-voltage characteristics of single-stage semiconductor magnetic pulse generators with a distinctive structure of the conversion link in the input circuit Optimal hybrid photovoltaic distributed generation and distribution static synchronous compensators planning to minimize active power losses using adaptive acceleration coefficients particle swarm optimization algorithms Estimation of electrical resistivity of conductive materials of random shapes Modeling and research of a magnetoelectric converter for hydro and pneumo actuators
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1