CROSS-CULTURAL ADAPTATION AND VALIDATION OF THE NEPALI VERSION OF THE PROSTHETIC LIMB USERS SURVEY OF MOBILITY SHORT-FORM (PLUS-M™/NEPALI-12SF) IN LOWER LIMB PROSTHESIS USERS

Amit Ratna Bajracharya, Sirirat Seng-iad, Kazuhiko Sasaki, Gary Guerra
{"title":"CROSS-CULTURAL ADAPTATION AND VALIDATION OF THE NEPALI VERSION OF THE PROSTHETIC LIMB USERS SURVEY OF MOBILITY SHORT-FORM (PLUS-M™/NEPALI-12SF) IN LOWER LIMB PROSTHESIS USERS","authors":"Amit Ratna Bajracharya, Sirirat Seng-iad, Kazuhiko Sasaki, Gary Guerra","doi":"10.33137/cpoj.v6i1.41310","DOIUrl":null,"url":null,"abstract":"BACKGROUND: Objective mobility measurement of Nepali prosthesis users is lacking. OBJECTIVE: The objective of this study was to cross-culturally adapt, translate and evaluate construct validity of the Prosthetic Limb Users Survey of Mobility (PLUS-M™/Nepali-12 Short Form (SF)) instrument in lower limb prosthesis users residing in Nepal. METHODOLOGY: Two forward translations, review and reconciliation, back translation, expert review, developer review to create the PLUS-M™/Nepali-12SF. Psychometric testing for internal consistency, test-retest reliability and construct validity against the Two-Minute Walk Test (2MWT) and Amputee Mobility Predictor with Prosthesis (AMPPRO) were performed on sixty-six lower limb prosthesis users. FINDINGS: The majority of populations were with transtibial amputation 45 (68%), with transfemoral amputation 15 (23%), with knee disarticulation 5 (7.5%) and with syme’s amputation 1 (1.5%). The most common cause of amputation among the population was trauma and the least was tumor. Chronbach’s alpha for the PLUS-M™/Nepali-12SF was 0.90, mean T-Score was 52.90, test-retest intraclass correlation coefficient (ICC) was 0.94 (95% confidence interval 0.90-0.96). Construct validity with the 2MWT was good (r = 0.62, p< 0.001) and moderately positive with the AMPPRO (r = 0.57, p< 0.001). CONCLUSION: Our research evidenced that the PLUS-M™/Nepali -12SF had excellent reproducibility. The significance of this work is that it may allow for the measurement of mobility in austere locations of Nepal. Layman's Abstract In this research, the authors performed a cross-cultural translation and validation of a Prosthetic Limb Users Survey of Mobility (PLUS-MTM). Understanding mobility of lower limb prosthesis user is important for understanding effect of prosthetic limb treatment. One simple and valid way to measure this is to administer a short survey. The PLUS-MTM survey was designed for lower limb prosthesis users whom can walk independently without assistance; however, a Nepali version did not exist. Translation of the PLUS-MTM occurred and Nepali lower limb prosthesis users were provided the survey. Moreover, survey scores were compared with users performances on a walking performance test called the Two-Minute Walk Test (2MWT) and Amputee Mobility Predictor with Prosthesis (AMPPRO). After comparison, it was found that the PLUS-MTM survey was more appropriate with Nepali culture, with good association between of PLUS-MTM with 2MWT, and AMPPRO scores. Meaning, if users scored high on the mobility survey they were also likely to score high on the walking test. The PLUS-MTM can now be confidently used in Nepal to track mobility of independent lower limb prosthesis users who can walk without other person’s assistance. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/41310/31816 How To Cite: Bajracharya AR, Seng-iad S, Sasaki K, Guerra G. Cross-cultural adaptation and validation of the Nepali version of the Prosthetic Limb Users Survey of Mobility Short-Form (PLUS-M™/Nepali-12SF) in lower limb prosthesis users. Canadian Prosthetics &amp; Orthotics Journal. 2023; Volume 6, Issue 1, No.1. https://doi.org/10.33137/cpoj.v6i1.41310 Corresponding Author: Sirirat-Seng-iad, Sirindhorn School of Prosthetics and Orthotics, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.E-Mail: sirirat.sen@mahidol.edu ORCID ID: https://orcid.org/0009-0008-7187-3593","PeriodicalId":32763,"journal":{"name":"Canadian Prosthetics Orthotics Journal","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Prosthetics Orthotics Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33137/cpoj.v6i1.41310","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

BACKGROUND: Objective mobility measurement of Nepali prosthesis users is lacking. OBJECTIVE: The objective of this study was to cross-culturally adapt, translate and evaluate construct validity of the Prosthetic Limb Users Survey of Mobility (PLUS-M™/Nepali-12 Short Form (SF)) instrument in lower limb prosthesis users residing in Nepal. METHODOLOGY: Two forward translations, review and reconciliation, back translation, expert review, developer review to create the PLUS-M™/Nepali-12SF. Psychometric testing for internal consistency, test-retest reliability and construct validity against the Two-Minute Walk Test (2MWT) and Amputee Mobility Predictor with Prosthesis (AMPPRO) were performed on sixty-six lower limb prosthesis users. FINDINGS: The majority of populations were with transtibial amputation 45 (68%), with transfemoral amputation 15 (23%), with knee disarticulation 5 (7.5%) and with syme’s amputation 1 (1.5%). The most common cause of amputation among the population was trauma and the least was tumor. Chronbach’s alpha for the PLUS-M™/Nepali-12SF was 0.90, mean T-Score was 52.90, test-retest intraclass correlation coefficient (ICC) was 0.94 (95% confidence interval 0.90-0.96). Construct validity with the 2MWT was good (r = 0.62, p< 0.001) and moderately positive with the AMPPRO (r = 0.57, p< 0.001). CONCLUSION: Our research evidenced that the PLUS-M™/Nepali -12SF had excellent reproducibility. The significance of this work is that it may allow for the measurement of mobility in austere locations of Nepal. Layman's Abstract In this research, the authors performed a cross-cultural translation and validation of a Prosthetic Limb Users Survey of Mobility (PLUS-MTM). Understanding mobility of lower limb prosthesis user is important for understanding effect of prosthetic limb treatment. One simple and valid way to measure this is to administer a short survey. The PLUS-MTM survey was designed for lower limb prosthesis users whom can walk independently without assistance; however, a Nepali version did not exist. Translation of the PLUS-MTM occurred and Nepali lower limb prosthesis users were provided the survey. Moreover, survey scores were compared with users performances on a walking performance test called the Two-Minute Walk Test (2MWT) and Amputee Mobility Predictor with Prosthesis (AMPPRO). After comparison, it was found that the PLUS-MTM survey was more appropriate with Nepali culture, with good association between of PLUS-MTM with 2MWT, and AMPPRO scores. Meaning, if users scored high on the mobility survey they were also likely to score high on the walking test. The PLUS-MTM can now be confidently used in Nepal to track mobility of independent lower limb prosthesis users who can walk without other person’s assistance. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/41310/31816 How To Cite: Bajracharya AR, Seng-iad S, Sasaki K, Guerra G. Cross-cultural adaptation and validation of the Nepali version of the Prosthetic Limb Users Survey of Mobility Short-Form (PLUS-M™/Nepali-12SF) in lower limb prosthesis users. Canadian Prosthetics & Orthotics Journal. 2023; Volume 6, Issue 1, No.1. https://doi.org/10.33137/cpoj.v6i1.41310 Corresponding Author: Sirirat-Seng-iad, Sirindhorn School of Prosthetics and Orthotics, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.E-Mail: sirirat.sen@mahidol.edu ORCID ID: https://orcid.org/0009-0008-7187-3593
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
尼泊尔版假肢使用者移动性简表(plus-m™/ nepal - 12sf)在下肢假肢使用者中的跨文化适应与验证
背景:目的尼泊尔义肢使用者的活动能力测量缺乏。目的:本研究的目的是跨文化适应、翻译和评估假肢使用者活动能力调查(PLUS-M™/Nepal -12 Short Form (SF))工具在尼泊尔下肢假肢使用者中的结构效度。方法:两个正向翻译,审查和协调,反向翻译,专家审查,开发人员审查,以创建PLUS-M™/ nepal - 12sf。对66名下肢义肢使用者进行了两分钟步行测试(2MWT)和假肢截肢者活动预测器(AMPPRO)的内部一致性、重测信度和结构效度的心理测试。结果:大多数人群为经胫骨截肢45例(68%),经股骨截肢15例(23%),膝关节脱臼5例(7.5%),syme截肢1例(1.5%)。在人群中,最常见的截肢原因是创伤,最少的是肿瘤。PLUS-M™/ nepal - 12sf的Chronbach 's alpha为0.90,平均T-Score为52.90,重测类内相关系数(ICC)为0.94(95%置信区间0.90-0.96)。2MWT的结构效度较好(r = 0.62, p<0.001), AMPPRO中度阳性(r = 0.57, p<0.001)。结论:我们的研究证明,PLUS-M™/Nepali -12SF具有良好的重复性。这项工作的意义在于,它可以测量尼泊尔严峻地区的流动性。在本研究中,作者对一份假肢使用者移动能力调查(PLUS-MTM)进行了跨文化翻译和验证。了解下肢义肢使用者的活动能力对了解义肢治疗效果具有重要意义。一个简单有效的测量方法是进行一个简短的调查。PLUS-MTM调查是为能够独立行走的下肢义肢使用者设计的;然而,尼泊尔文的版本并不存在。翻译PLUS-MTM发生和尼泊尔下肢假体用户提供的调查。此外,调查得分与用户在步行性能测试中的表现进行了比较,该测试被称为两分钟步行测试(2MWT)和截肢者假肢运动预测器(AMPPRO)。经过比较,发现PLUS-MTM调查更适合尼泊尔文化,PLUS-MTM与2MWT、AMPPRO得分之间有良好的相关性。也就是说,如果用户在移动调查中得分高,他们在步行测试中也可能得分高。PLUS-MTM现在可以在尼泊尔放心地使用,以跟踪独立下肢假肢使用者的活动能力,这些使用者可以在没有其他人帮助的情况下行走。文章PDF链接:https://jps.library.utoronto.ca/index.php/cpoj/article/view/41310/31816如何引用:Bajracharya AR, sseng -iad S, Sasaki K, Guerra G.尼泊尔版假肢使用者移动简短形式调查(PLUS-M™/ nepal - 12sf)的跨文化适应和验证。加拿大假肢Orthotics Journal. 2023;第6卷第1期第1期https://doi.org/10.33137/cpoj.v6i1.41310通讯作者:Sirirat-Seng-iad,泰国曼谷玛希隆大学Siriraj医院医学院诗琳通修复矫形学院。电子邮件:sirirat.sen@mahidol.edu或ID: https://orcid.org/0009-0008-7187-3593
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Canadian Prosthetics  Orthotics Journal
Canadian Prosthetics Orthotics Journal Medicine-Rehabilitation
CiteScore
1.00
自引率
0.00%
发文量
9
审稿时长
8 weeks
期刊最新文献
Exploring the need for lower limb prosthetic guidelines in South Africa's private healthcare sector. Development and evaluation of an anteriorly mounted microprocessor-controlled powered hip joint prosthesis. Prevalence of work-related musculoskeletal disorders among Iranian orthotists and prosthetists: A study on work-related quality of life. Prosthetist Knowledge and 3D Printing. Overcoming barriers to cycling for knee disarticulation and transfemoral prosthesis users: A pilot study in The Netherlands.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1