{"title":"Development and evaluation of an anteriorly mounted microprocessor-controlled powered hip joint prosthesis.","authors":"K Brannen, N Baddour, L Cho, D Langlois, P Dumond, E D Lemaire","doi":"10.33137/cpoj.v7i2.44494","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Prosthetic solutions for individuals with hip disarticulation and hemipelvectomy amputations currently rely exclusively on passive hip joint mechanisms. Although powered knee and ankle joint prostheses have improved gait in people with amputation, no powered hip joint options are commercially available.</p><p><strong>Objective: </strong>To develop and validate the mechanism, structural integrity, and design of an anteriorly mounted powered hip joint prosthesis.</p><p><strong>Methodology: </strong>A microprocessor-controlled powered hip joint prosthesis (PHP) was developed, incorporating a cable-and-pulley transmission system. Stress calculations and Finite Element Analysis (FEA) were performed to ensure that the device can withstand the forces from daily activities. The prototype underwent mechanical strength testing in accordance with International Organization for Standardization (ISO) 15032:2000 standards, ensuring suitability for user loads of up to 100 kg. For functional testing, three able-bodied individuals were video recorded while walking with the power hip in a prosthesis simulator. For each participant, hip angles and stride parameters during level walking were assessed by analyzing five gait cycles.</p><p><strong>Findings: </strong>The novel PHP met most of the design criteria; however, it protruded 56 mm anteriorly from the lamination plate, exceeding the specified criterion of 20 mm. The joint's range of motion included 22° of extension and 145° of flexion. The joint prototype's height was 347 mm, and it weighed 3.9 kg. Furthermore, it passed ISO 15032:2000 strength tests, withstanding a 3360 Newton (N) load without failure. The device successfully enabled able-bodied individuals to walk using a hip disarticulation simulator and supported a 98 kg user during level walking.</p><p><strong>Conclusion: </strong>The microprocessor-controlled PHP exhibited successful performance in both mechanical strength and functional testing. Future work is needed to optimize and assess the design, which could reduce the device's weight and size. A complex control system to adjust gait based on pelvic motion is currently under development.</p>","PeriodicalId":32763,"journal":{"name":"Canadian Prosthetics Orthotics Journal","volume":"7 2","pages":"44494"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11844763/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Prosthetics Orthotics Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33137/cpoj.v7i2.44494","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Prosthetic solutions for individuals with hip disarticulation and hemipelvectomy amputations currently rely exclusively on passive hip joint mechanisms. Although powered knee and ankle joint prostheses have improved gait in people with amputation, no powered hip joint options are commercially available.

Objective: To develop and validate the mechanism, structural integrity, and design of an anteriorly mounted powered hip joint prosthesis.

Methodology: A microprocessor-controlled powered hip joint prosthesis (PHP) was developed, incorporating a cable-and-pulley transmission system. Stress calculations and Finite Element Analysis (FEA) were performed to ensure that the device can withstand the forces from daily activities. The prototype underwent mechanical strength testing in accordance with International Organization for Standardization (ISO) 15032:2000 standards, ensuring suitability for user loads of up to 100 kg. For functional testing, three able-bodied individuals were video recorded while walking with the power hip in a prosthesis simulator. For each participant, hip angles and stride parameters during level walking were assessed by analyzing five gait cycles.

Findings: The novel PHP met most of the design criteria; however, it protruded 56 mm anteriorly from the lamination plate, exceeding the specified criterion of 20 mm. The joint's range of motion included 22° of extension and 145° of flexion. The joint prototype's height was 347 mm, and it weighed 3.9 kg. Furthermore, it passed ISO 15032:2000 strength tests, withstanding a 3360 Newton (N) load without failure. The device successfully enabled able-bodied individuals to walk using a hip disarticulation simulator and supported a 98 kg user during level walking.

Conclusion: The microprocessor-controlled PHP exhibited successful performance in both mechanical strength and functional testing. Future work is needed to optimize and assess the design, which could reduce the device's weight and size. A complex control system to adjust gait based on pelvic motion is currently under development.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Canadian Prosthetics  Orthotics Journal
Canadian Prosthetics Orthotics Journal Medicine-Rehabilitation
CiteScore
1.00
自引率
0.00%
发文量
9
审稿时长
8 weeks
期刊最新文献
Exploring the need for lower limb prosthetic guidelines in South Africa's private healthcare sector. Development and evaluation of an anteriorly mounted microprocessor-controlled powered hip joint prosthesis. Prevalence of work-related musculoskeletal disorders among Iranian orthotists and prosthetists: A study on work-related quality of life. Prosthetist Knowledge and 3D Printing. Overcoming barriers to cycling for knee disarticulation and transfemoral prosthesis users: A pilot study in The Netherlands.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1