On the Possibility of Using Medical Linear Electron Accelerators as a Source of the Reference Pulsed Photon Radiation Field

IF 0.2 Q4 INSTRUMENTS & INSTRUMENTATION Devices and Methods of Measurements Pub Date : 2023-10-05 DOI:10.21122/2220-9506-2023-14-3-179-190
A. A. Zaharadniuk, A. Y. Taraev, S. V. Lazarenko
{"title":"On the Possibility of Using Medical Linear Electron Accelerators as a Source of the Reference Pulsed Photon Radiation Field","authors":"A. A. Zaharadniuk, A. Y. Taraev, S. V. Lazarenko","doi":"10.21122/2220-9506-2023-14-3-179-190","DOIUrl":null,"url":null,"abstract":"Sources of pulsed photon radiation are widely used in science and industry. In this regard, there is a growing demand for dosimetry instruments capable of operating in these pulsed photon radiation fields. Until now there is no comprehensive methodology that describes the characteristics of reference fields of pulsed photon radiation required for calibration and verification of dosimetry equipment. The aim of this paper was to study the possibility of using a medical linear electron accelerator as a generating source of a reference pulsed photon radiation field. The paper investigates main characteristics of photon radiation field (namely, spectrum and average energy) generated by CLINAC in two modes of operation: 6 MV and 18 MV. Additionally it researches the possibility of attenuation of the CLINAC photon radiation intensity by a lead filter. The spectrum and average energy of the CLINAC photon radiation were calculated by means of Monte Carlo simulation in the Fluka program. The validation of the calculation was determined by comparing the attenuation coefficients calculated by the model with ones obtained experimentally by using real CLINACs. Experimentally, the attenuation coefficients were obtained by measuring the air kerma rate generated by the photon radiation fields of Varian VitalBeam and Varian iX CLINACs at a given point of space. Based on the simulation results, the Ḣ *(10) ambient dose equivalent ratio generated by CLINACs were calculated. It was found that the lead filter effectively attenuates the CLINAC photon radiation in terms of both air kerma rate and ambient dose equivalent rate to levels suitable for calibration of dosimetry equipment designed to measure pulsed radiation. It is shown that the lead filter significantly affects both the photon spectrum of the CLINAC and its average energy.","PeriodicalId":41798,"journal":{"name":"Devices and Methods of Measurements","volume":"468 1","pages":"0"},"PeriodicalIF":0.2000,"publicationDate":"2023-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Devices and Methods of Measurements","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21122/2220-9506-2023-14-3-179-190","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Sources of pulsed photon radiation are widely used in science and industry. In this regard, there is a growing demand for dosimetry instruments capable of operating in these pulsed photon radiation fields. Until now there is no comprehensive methodology that describes the characteristics of reference fields of pulsed photon radiation required for calibration and verification of dosimetry equipment. The aim of this paper was to study the possibility of using a medical linear electron accelerator as a generating source of a reference pulsed photon radiation field. The paper investigates main characteristics of photon radiation field (namely, spectrum and average energy) generated by CLINAC in two modes of operation: 6 MV and 18 MV. Additionally it researches the possibility of attenuation of the CLINAC photon radiation intensity by a lead filter. The spectrum and average energy of the CLINAC photon radiation were calculated by means of Monte Carlo simulation in the Fluka program. The validation of the calculation was determined by comparing the attenuation coefficients calculated by the model with ones obtained experimentally by using real CLINACs. Experimentally, the attenuation coefficients were obtained by measuring the air kerma rate generated by the photon radiation fields of Varian VitalBeam and Varian iX CLINACs at a given point of space. Based on the simulation results, the Ḣ *(10) ambient dose equivalent ratio generated by CLINACs were calculated. It was found that the lead filter effectively attenuates the CLINAC photon radiation in terms of both air kerma rate and ambient dose equivalent rate to levels suitable for calibration of dosimetry equipment designed to measure pulsed radiation. It is shown that the lead filter significantly affects both the photon spectrum of the CLINAC and its average energy.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
医用直线电子加速器作为参考脉冲光子辐射场源的可能性
脉冲光子辐射源广泛应用于科学和工业。在这方面,对能够在这些脉冲光子辐射场中工作的剂量测量仪器的需求日益增长。到目前为止,还没有一种综合的方法来描述剂量测量设备校准和验证所需的脉冲光子辐射参考场的特性。本文的目的是研究使用医用直线电子加速器作为参考脉冲光子辐射场产生源的可能性。本文研究了CLINAC在6 MV和18 MV两种工作模式下产生的光子辐射场的主要特性(即光谱和平均能量)。此外,还研究了铅滤光片对CLINAC光子辐射强度衰减的可能性。利用Fluka程序进行蒙特卡罗模拟,计算了CLINAC光子辐射的光谱和平均能量。将模型计算的衰减系数与实际CLINACs实验得到的衰减系数进行了比较,验证了计算结果的正确性。实验上,通过测量瓦里安VitalBeam和瓦里安iX CLINACs的光子辐射场在给定空间点上产生的空气kerma率,得到衰减系数。根据模拟结果,计算了CLINACs产生的Ḣ *(10)环境剂量当量比。研究发现,铅滤光片有效地将CLINAC光子辐射的空气可变性和环境剂量当量衰减到适合校准用于测量脉冲辐射的剂量学设备的水平。结果表明,铅滤光片对CLINAC的光子光谱和平均能量均有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Devices and Methods of Measurements
Devices and Methods of Measurements INSTRUMENTS & INSTRUMENTATION-
自引率
25.00%
发文量
18
审稿时长
8 weeks
期刊最新文献
Use of the Laser Beam Deflection Technique for Thermo-Optic Coefficients Study in Gadolinium-Yttrium Oxyorthosilicate Doped with Erbium Ions Electronic Shooting Simulator Family "STrIzh": Implementation Levels and Free Software Structure Optimal Printing and Post-Processing Modes of Polymer Products Manufactured Using SLA-Technology of Additive Мanufacturing Influence of Temperature from 20 to 100 °C on Specific Surface Energy and Fracture Toughness of Silicon Wafers Tin Oxide Modification of Indium Oxide Gas Sensitive Layers to Increase Efficiency of Gas Sensors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1