Anna Casari, Loris Tonidandel, Guido Zolezzi, Alberto Bellin, Paolo Negri, Alice Barbero, Roberto Larcher
{"title":"Validation of a calibration model able to estimate the concentration of pesticides in an alpine stream through passive sampling (POCIS) monitoring","authors":"Anna Casari, Loris Tonidandel, Guido Zolezzi, Alberto Bellin, Paolo Negri, Alice Barbero, Roberto Larcher","doi":"10.1071/en23052","DOIUrl":null,"url":null,"abstract":"Environmental context Pesticides and other contaminants released by agricultural activities negatively impact aquatic biota and water quality, but are not always measured. The Polar Organic Chemical Integrative Sampler (POCIS) is among the most suitable tools for identifying pesticides and other organic compounds in water bodies. However, determination of a mean concentration (over the duration of the deployment) is still a significant challenge, which is addressed in the present work using field observations and a computational model.Rationale The Polar Organic Chemical Integrative Sampler (POCIS) is a passive sampler composed of a receiving phase, Oasis HLB, enclosed between two polyethersulfone (PES) membranes. It is used for monitoring organic compounds in surface water and in groundwater. The measurement of pesticide concentrations by passive samplers in streams still represents an open challenge, which limits the samplers’ use in environmental monitoring of the quality status of water bodies in accordance with the EU Water Framework Directive.Methodology We addressed these limitations by calibrating a POCIS with concentration measurements performed on samples collected by means of an automatic sampler from the same section of a small alpine river where a passive sampler was deployed. In the majority of published studies, the analytes were extracted only from the receiving phase, but recent works show that some compounds were also adsorbed by the PES membrane, suggesting the importance of extracting the analytes from both the phase and the membrane.Results The POCIS was calibrated for 31 compounds, by a comparison between the total amount of pesticides adsorbed by POCIS (Ms) and the time-weighted average concentration (TWAc) obtained from several grab samples, and by estimation of the sampling rate (Rs), which allows linking the Ms with the TWAc over time. The data showed an increasing Rs trend with hydrophobicity for the most hydrophobic and hydrophilic compounds, while compounds with 1.5 ≤ log Kow ≤ 3.5 assumed a value of Rs independent of log Kow. The contribution of PES membranes allows expansion of the calibration of Rs to the most hydrophobic compounds and allows monitoring of pesticides that would hardly have been detected if they were extracted only from the Oasis HLB phase, such as fluazinam.Discussion The calibration was then verified on the same stream and the model extended to a different sampling site; in both cases, the calibration allowed estimation of a value of TWAc that fits with the reality within a factor of 5, and in the majority of cases within a factor of 2. If this level of accuracy is accepted, the Rs reported here can be used to estimate TWAc from sampling with POCIS.","PeriodicalId":11714,"journal":{"name":"Environmental Chemistry","volume":"40 1","pages":"0"},"PeriodicalIF":2.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1071/en23052","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Environmental context Pesticides and other contaminants released by agricultural activities negatively impact aquatic biota and water quality, but are not always measured. The Polar Organic Chemical Integrative Sampler (POCIS) is among the most suitable tools for identifying pesticides and other organic compounds in water bodies. However, determination of a mean concentration (over the duration of the deployment) is still a significant challenge, which is addressed in the present work using field observations and a computational model.Rationale The Polar Organic Chemical Integrative Sampler (POCIS) is a passive sampler composed of a receiving phase, Oasis HLB, enclosed between two polyethersulfone (PES) membranes. It is used for monitoring organic compounds in surface water and in groundwater. The measurement of pesticide concentrations by passive samplers in streams still represents an open challenge, which limits the samplers’ use in environmental monitoring of the quality status of water bodies in accordance with the EU Water Framework Directive.Methodology We addressed these limitations by calibrating a POCIS with concentration measurements performed on samples collected by means of an automatic sampler from the same section of a small alpine river where a passive sampler was deployed. In the majority of published studies, the analytes were extracted only from the receiving phase, but recent works show that some compounds were also adsorbed by the PES membrane, suggesting the importance of extracting the analytes from both the phase and the membrane.Results The POCIS was calibrated for 31 compounds, by a comparison between the total amount of pesticides adsorbed by POCIS (Ms) and the time-weighted average concentration (TWAc) obtained from several grab samples, and by estimation of the sampling rate (Rs), which allows linking the Ms with the TWAc over time. The data showed an increasing Rs trend with hydrophobicity for the most hydrophobic and hydrophilic compounds, while compounds with 1.5 ≤ log Kow ≤ 3.5 assumed a value of Rs independent of log Kow. The contribution of PES membranes allows expansion of the calibration of Rs to the most hydrophobic compounds and allows monitoring of pesticides that would hardly have been detected if they were extracted only from the Oasis HLB phase, such as fluazinam.Discussion The calibration was then verified on the same stream and the model extended to a different sampling site; in both cases, the calibration allowed estimation of a value of TWAc that fits with the reality within a factor of 5, and in the majority of cases within a factor of 2. If this level of accuracy is accepted, the Rs reported here can be used to estimate TWAc from sampling with POCIS.
期刊介绍:
Environmental Chemistry publishes manuscripts addressing the chemistry of the environment (air, water, earth, and biota), including the behaviour and impacts of contaminants and other anthropogenic disturbances. The scope encompasses atmospheric chemistry, geochemistry and biogeochemistry, climate change, marine and freshwater chemistry, polar chemistry, fire chemistry, soil and sediment chemistry, and chemical aspects of ecotoxicology. Papers that take an interdisciplinary approach, while advancing our understanding of the linkages between chemistry and physical or biological processes, are particularly encouraged.
While focusing on the publication of important original research and timely reviews, the journal also publishes essays and opinion pieces on issues of importance to environmental scientists, such as policy and funding.
Papers should be written in a style that is accessible to those outside the field, as the readership will include - in addition to chemists - biologists, toxicologists, soil scientists, and workers from government and industrial institutions. All manuscripts are rigorously peer-reviewed and professionally copy-edited.
Environmental Chemistry is published with the endorsement of the Commonwealth Scientific and Industrial Research Organisation (CSIRO) and the Australian Academy of Science.