Effect mechanism of ambient air parameters on the thermal performance for cooling towers

IF 1.6 4区 工程技术 Q3 ENGINEERING, MECHANICAL Journal of Thermal Science and Engineering Applications Pub Date : 2023-10-20 DOI:10.1115/1.4063875
Lei Zhang, Jun Zhou, Simeng Zuo, Guangyao An, Jinhua Lang, Wei Yuan
{"title":"Effect mechanism of ambient air parameters on the thermal performance for cooling towers","authors":"Lei Zhang, Jun Zhou, Simeng Zuo, Guangyao An, Jinhua Lang, Wei Yuan","doi":"10.1115/1.4063875","DOIUrl":null,"url":null,"abstract":"Abstract With the increasing volume of the cooling tower, the influence of environmental factors on the thermal performance of the cooling tower is not clear. Therefore, in order to more comprehensively study the influence mechanism of ambient air parameters on the thermal performance of the natural draft wet cooling tower, the key parameters such as gas-water ratio, circulating water temperature difference and heat transfer in each zone are calculated, and the temperature field and humidity field are also investigated. The results show that the circulating water temperature difference decreases most with the increase of ambient temperature, which is 7.63°C. However, atmospheric pressure makes the circulating water temperature difference decrease the least, which is 0.95°C, resulting in the decrease of heat transfer in the three zones by 14.9%, 10.6% and 26.0% respectively. The increase of relative humidity and atmospheric pressure leads to the increase of contact heat transfer and the decrease of evaporative mass transfer. The increase of ambient temperature makes the contact heat transfer and evaporative mass transfer decrease, and finally the heat and mass transfer capacity of the cooling tower decreases. This study establishes a theoretical basis for further optimization of the thermal performance and energy-saving design of cooling towers.","PeriodicalId":17404,"journal":{"name":"Journal of Thermal Science and Engineering Applications","volume":"502 1","pages":"0"},"PeriodicalIF":1.6000,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermal Science and Engineering Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4063875","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract With the increasing volume of the cooling tower, the influence of environmental factors on the thermal performance of the cooling tower is not clear. Therefore, in order to more comprehensively study the influence mechanism of ambient air parameters on the thermal performance of the natural draft wet cooling tower, the key parameters such as gas-water ratio, circulating water temperature difference and heat transfer in each zone are calculated, and the temperature field and humidity field are also investigated. The results show that the circulating water temperature difference decreases most with the increase of ambient temperature, which is 7.63°C. However, atmospheric pressure makes the circulating water temperature difference decrease the least, which is 0.95°C, resulting in the decrease of heat transfer in the three zones by 14.9%, 10.6% and 26.0% respectively. The increase of relative humidity and atmospheric pressure leads to the increase of contact heat transfer and the decrease of evaporative mass transfer. The increase of ambient temperature makes the contact heat transfer and evaporative mass transfer decrease, and finally the heat and mass transfer capacity of the cooling tower decreases. This study establishes a theoretical basis for further optimization of the thermal performance and energy-saving design of cooling towers.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
环境空气参数对冷却塔热工性能的影响机理
摘要随着冷却塔容积的不断增大,环境因素对冷却塔热工性能的影响尚不清楚。因此,为了更全面地研究环境空气参数对自然通风湿式冷却塔热工性能的影响机理,对各区域的气水比、循环水温差、换热等关键参数进行了计算,并对温度场和湿度场进行了研究。结果表明:随着环境温度的升高,循环水温差减小幅度最大,为7.63℃;而大气压使循环水温差减小最小,为0.95℃,导致三区换热分别减小14.9%、10.6%和26.0%。相对湿度和大气压力的增大导致接触换热增大,蒸发传质减小。环境温度的升高使冷却塔的接触传热和蒸发传质减小,最终使冷却塔的传热和传质能力减小。本研究为进一步优化冷却塔的热工性能和节能设计奠定了理论基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Thermal Science and Engineering Applications
Journal of Thermal Science and Engineering Applications THERMODYNAMICSENGINEERING, MECHANICAL -ENGINEERING, MECHANICAL
CiteScore
3.60
自引率
9.50%
发文量
120
期刊介绍: Applications in: Aerospace systems; Gas turbines; Biotechnology; Defense systems; Electronic and photonic equipment; Energy systems; Manufacturing; Refrigeration and air conditioning; Homeland security systems; Micro- and nanoscale devices; Petrochemical processing; Medical systems; Energy efficiency; Sustainability; Solar systems; Combustion systems
期刊最新文献
Improving turbine endwall overall cooling effectiveness using curtain cooling and redistributed film-hole layouts: an experimental and computational study Soft Computing Model for Inverse Prediction of Surface Heat Flux from Temperature Responses in Short-Duration Heat Transfer Experiments Aerothermal Optimization of Film Cooling Hole Locations on the Squealer Tip of an HP Turbine Blade Theoretical investigation of low global warming potential blends replacing R404A: the simple refrigeration cycle and its modifications Study on the Influence of Fan and Fan Cowl on Intake Air Parameters of Cooling Module
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1