Nur Athirah binti Khalit, Zuraini binti Denan, Aliyah Nur Zafirah binti Sanusi, Norwina binti Mohd Nawawi
{"title":"Assessment of Indoor Thermal Condition on Traditional Vernacular Masjid: A Case Study on Masjid Kampung Laut, Malaysia","authors":"Nur Athirah binti Khalit, Zuraini binti Denan, Aliyah Nur Zafirah binti Sanusi, Norwina binti Mohd Nawawi","doi":"10.17576/jkukm-2023-35(3)-12","DOIUrl":null,"url":null,"abstract":"Traditional vernacular architectures in Malaysia include public buildings such as a masjid were designed with the tropical climate in mind and have proven to be an excellent example of providing indoor thermal comfort to the occupants. It is a naturally ventilated building being greatly influenced by the building designs. In traditional vernacular architecture, the roof is the main building enclosure that contributes to the total heat gain. Hence, the research aims to assess the indoor thermal condition of Masjid Kampung Laut, Kelantan, the first traditional vernacular masjid in Malaysia. Data were collected using the method of field measurement to evaluate the indoor comfort level of the masjid, in terms of indoor air temperature, air velocity, and relative humidity. The results demonstrate that the average indoor air temperature is acceptable and Masjid Kampung Laut responded favorably to the local climate. However, it is believed that with an increase of 0.4m/s to 1.2m/s of air movement, will further enhance indoor thermal comfort. Therefore, the findings can guide further thermal comfort prediction studies for other naturally ventilated buildings. Several other potential passive design strategies for roof design are proposed in this study to achieve acceptable indoor thermal comfort conditions for the masjid in Malaysia.","PeriodicalId":17688,"journal":{"name":"Jurnal Kejuruteraan","volume":"8 1","pages":"0"},"PeriodicalIF":0.6000,"publicationDate":"2023-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Kejuruteraan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17576/jkukm-2023-35(3)-12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Traditional vernacular architectures in Malaysia include public buildings such as a masjid were designed with the tropical climate in mind and have proven to be an excellent example of providing indoor thermal comfort to the occupants. It is a naturally ventilated building being greatly influenced by the building designs. In traditional vernacular architecture, the roof is the main building enclosure that contributes to the total heat gain. Hence, the research aims to assess the indoor thermal condition of Masjid Kampung Laut, Kelantan, the first traditional vernacular masjid in Malaysia. Data were collected using the method of field measurement to evaluate the indoor comfort level of the masjid, in terms of indoor air temperature, air velocity, and relative humidity. The results demonstrate that the average indoor air temperature is acceptable and Masjid Kampung Laut responded favorably to the local climate. However, it is believed that with an increase of 0.4m/s to 1.2m/s of air movement, will further enhance indoor thermal comfort. Therefore, the findings can guide further thermal comfort prediction studies for other naturally ventilated buildings. Several other potential passive design strategies for roof design are proposed in this study to achieve acceptable indoor thermal comfort conditions for the masjid in Malaysia.
马来西亚的传统乡土建筑包括公共建筑,如清真寺,在设计时考虑到热带气候,并已被证明是为居住者提供室内热舒适的一个很好的例子。它是一个自然通风的建筑,受建筑设计的影响很大。在传统的乡土建筑中,屋顶是主要的建筑围护结构,有助于获得总热量。因此,本研究旨在评估马来西亚第一座传统民居清真寺吉兰丹甘榜劳清真寺(Masjid Kampung Laut)的室内热状况。采用现场测量的方法收集数据,从室内空气温度、风速和相对湿度等方面评价清真寺的室内舒适度。结果表明,平均室内温度是可以接受的,甘榜劳清真寺对当地气候有良好的反应。但是,相信随着0.4m/s到1.2m/s的空气移动,将进一步增强室内热舒适性。因此,研究结果可以指导其他自然通风建筑的热舒适预测研究。本研究提出了其他几种潜在的被动式屋顶设计策略,以实现马来西亚清真寺可接受的室内热舒适条件。