IMPEDANCE AND ELECTRICALLY EVOKED COMPOUND ACTION POTENTIAL (ECAP) CHANGES OVERTIME IN PATIENTS WITH COCHLEAR IMPLANTS

Sara Tawfeek, Adel Nassar, Tayseer Abdel Rahman, Ghada Khalil
{"title":"IMPEDANCE AND ELECTRICALLY EVOKED COMPOUND ACTION POTENTIAL (ECAP) CHANGES OVERTIME IN PATIENTS WITH COCHLEAR IMPLANTS","authors":"Sara Tawfeek, Adel Nassar, Tayseer Abdel Rahman, Ghada Khalil","doi":"10.21608/asmj.2023.321910","DOIUrl":null,"url":null,"abstract":": Background: Cochlear implantation referred to as the treatment of choice for hearing rehabilitation in patients with bilateral severe to profound sensorineural hearing loss that is no longer responsive to amplification by hearing aids. The integrity of this CI can be assessed intraoperatively and postoperatively through objective measures which include telemetric measurement of electrode impedance and electrically evoked compound action potential. Aim of the work: To compare electrode impedance values and electrically evoked compound action potential (ECAP) thresholds intraoperatively and postoperatively to asses whether significant changes take place overtime or not. Patient and Methods This study was carried on 25 subjects with age ranging from (3-60) yrs. 21 of the subjects were implanted unilaterally with a MED-EL devices and 4 implanted with cochlear devices. Impedance values and ECAP thresholds were monitored at the time of surgery then postoperatively at 1 st day tunning, 1 month, 2 months and 6 th months after 1 st day tunning. Results: Intraoperative impedance value was the lowest among all readings measured in all electrodes. The highest value was that measured at the 1 st day tunning after surgery, after which impedance value continued to decrease significantly when compared to the 1 st day tunning. ECAP thresholds showed the highest value intraoperatively after which the ECAP continued to decrease. However, the difference between readings was statistically nonsignificant. Conclusion: During surgery, telemetry provides valuable information regarding integrity of electrodes, the electrical output of the implant and the response of the auditory system to electrical stimulation; however, it is not a valuable predictor of post-operative performance.","PeriodicalId":7450,"journal":{"name":"Ain Shams Medical Journal","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ain Shams Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/asmj.2023.321910","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

: Background: Cochlear implantation referred to as the treatment of choice for hearing rehabilitation in patients with bilateral severe to profound sensorineural hearing loss that is no longer responsive to amplification by hearing aids. The integrity of this CI can be assessed intraoperatively and postoperatively through objective measures which include telemetric measurement of electrode impedance and electrically evoked compound action potential. Aim of the work: To compare electrode impedance values and electrically evoked compound action potential (ECAP) thresholds intraoperatively and postoperatively to asses whether significant changes take place overtime or not. Patient and Methods This study was carried on 25 subjects with age ranging from (3-60) yrs. 21 of the subjects were implanted unilaterally with a MED-EL devices and 4 implanted with cochlear devices. Impedance values and ECAP thresholds were monitored at the time of surgery then postoperatively at 1 st day tunning, 1 month, 2 months and 6 th months after 1 st day tunning. Results: Intraoperative impedance value was the lowest among all readings measured in all electrodes. The highest value was that measured at the 1 st day tunning after surgery, after which impedance value continued to decrease significantly when compared to the 1 st day tunning. ECAP thresholds showed the highest value intraoperatively after which the ECAP continued to decrease. However, the difference between readings was statistically nonsignificant. Conclusion: During surgery, telemetry provides valuable information regarding integrity of electrodes, the electrical output of the implant and the response of the auditory system to electrical stimulation; however, it is not a valuable predictor of post-operative performance.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
耳蜗植入患者的阻抗和电诱发复合动作电位随时间变化
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Serum Erythroferrone, a Biomarker of Erythropoietic Activity in End-Stage Renal Disease Patients Fibromyalgia and Depression in Egyptian Medical Students: A Cross-sectional Study of Impact on Physical Functional Status Polycystic ovary syndrome (PCOS) – A Review Prevalence and Factors Associated with Medication non-adherence among diabetic patients Attending at Menoufia University Hospitals Proportion and Determinants of Fibromyalgia in a Sample of Egyptians with Higher Education (Physicians and Non-physicians): A Comparative Cross-sectional Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1