Reliability of Software Prediction of Post Orthodontic Treatment Changes

Swatika Sankrit, Ankur Gupta, Dhruv Krishana Tiwari, Anil K. Chandana, Preeti Bhattacharya, Ravi Bhandari, Shivani Singh
{"title":"Reliability of Software Prediction of Post Orthodontic Treatment Changes","authors":"Swatika Sankrit, Ankur Gupta, Dhruv Krishana Tiwari, Anil K. Chandana, Preeti Bhattacharya, Ravi Bhandari, Shivani Singh","doi":"10.1177/03015742231188212","DOIUrl":null,"url":null,"abstract":"Aim The aim of this study was to assess the accuracy of Dolphin VTO prediction in patients requiring extraction treatment by comparing the VTO-predicted values and post-treatment values. Method Digital pre and post-treatment lateral cephalograms of 52 patients having Class I bimaxillary protrusion were taken and transferred in Dolphin Imaging software for analysis and VTO prediction. A composite analysis was made containing 17 dental and soft tissue parameters (Holdaway, Mc Namara, Rakosi, Steiners, and Tweed analysis). Results A comparison between post-treatment and VTO-predicted values showed that software was able to predict soft tissue changes accurately in regions such as nose, inferior sulcus depth, and chin region ( p > .05). In dental changes, software was able to predict the inclination of upper incisors to Sn and palatal plane correctly ( p > .05). Parameters for other areas such as upper and lower lip, position of upper and lower incisor show significant difference in their VTO and post-treatment values ( p < .05) showing inaccuracy of the software. Conclusion The VTO prediction of dental and soft tissue changes was significantly different from the post-treatment values for parameters such as superior sulcus depth, lower lip to h line, subnasal to h line, upper lip thickness, lip strain, nasolabial angle, interincisal angle, Ui-NA, Li-NB, and IMPA. For nasal prominence, inferior sulcus depth, chin thickness, UI-SN, and UI-PP, there was no significant difference seen. Since, for most of the parameters, a significant difference was found between the post-treatment and the predicted values, so it was inferred that the software-based VTO prediction could not be fully relied for any treatment planning.","PeriodicalId":31847,"journal":{"name":"Journal of Indian Orthodontic Society","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian Orthodontic Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/03015742231188212","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aim The aim of this study was to assess the accuracy of Dolphin VTO prediction in patients requiring extraction treatment by comparing the VTO-predicted values and post-treatment values. Method Digital pre and post-treatment lateral cephalograms of 52 patients having Class I bimaxillary protrusion were taken and transferred in Dolphin Imaging software for analysis and VTO prediction. A composite analysis was made containing 17 dental and soft tissue parameters (Holdaway, Mc Namara, Rakosi, Steiners, and Tweed analysis). Results A comparison between post-treatment and VTO-predicted values showed that software was able to predict soft tissue changes accurately in regions such as nose, inferior sulcus depth, and chin region ( p > .05). In dental changes, software was able to predict the inclination of upper incisors to Sn and palatal plane correctly ( p > .05). Parameters for other areas such as upper and lower lip, position of upper and lower incisor show significant difference in their VTO and post-treatment values ( p < .05) showing inaccuracy of the software. Conclusion The VTO prediction of dental and soft tissue changes was significantly different from the post-treatment values for parameters such as superior sulcus depth, lower lip to h line, subnasal to h line, upper lip thickness, lip strain, nasolabial angle, interincisal angle, Ui-NA, Li-NB, and IMPA. For nasal prominence, inferior sulcus depth, chin thickness, UI-SN, and UI-PP, there was no significant difference seen. Since, for most of the parameters, a significant difference was found between the post-treatment and the predicted values, so it was inferred that the software-based VTO prediction could not be fully relied for any treatment planning.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
正畸术后治疗变化软件预测的可靠性
目的本研究旨在通过比较VTO预测值和治疗后值来评估Dolphin预测拔牙患者VTO的准确性。方法对52例I类双颌前突患者进行治疗前后的数字侧位脑电图,并在Dolphin Imaging软件中进行分析和VTO预测。进行了包含17个牙齿和软组织参数的复合分析(Holdaway, Mc Namara, Rakosi, Steiners和Tweed分析)。结果术后与vto预测值的比较表明,软件能够准确预测鼻部、下沟深度、颏部等区域的软组织变化(p >. 05)。在牙齿变化中,软件能够正确预测上切牙对Sn和腭平面的倾斜度(p >. 05)。上下唇、上下切牙位置等其他部位参数的VTO及处理后值差异有统计学意义(p <.05)显示软件不准确。结论VTO预测的上沟深度、下唇至h线、鼻下至h线、上唇厚度、唇应变、鼻唇角、牙内角、Ui-NA、Li-NB、IMPA等参数与治疗后差异有统计学意义。在鼻突、下沟深度、下巴厚度、UI-SN、UI-PP方面,两组间无显著差异。由于大多数参数处理后与预测值存在显著差异,因此可以推断,对于任何治疗方案,基于软件的VTO预测都不能完全依赖。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
46
审稿时长
10 weeks
期刊最新文献
Accuracy of 3D Printing in Orthodontics: A Systematic Review and Meta-analysis Unified Denovo Multipurpose Analyzer Hard to Soft Tissue Profile Changes in Skeletal Class III Dentofacial Deformities After Maxillary Advancement and Mandibular Setback Orthognathic Surgery To Evaluate the Relationship between Maxillary and Mandibular Base Lengths with Dental Crowding in Different Skeletal Malocclusions Influence of Three Different Vertical Positions 
of MARPE Expander on Maxillofacial Complex: 
A Finite Element Analysis*
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1