Muhammad Rifat Hidayat, Ahmad Basshofi Habieb, Wahyuniarih Sutrisno
{"title":"NUMERICAL STUDY OF USING MULTI-DIRECTION ANGLE WIRE MESH AS A CONFINEMENT SYSTEM FOR CONFINED MASONRY UNDER HORIZONTAL CYCLIC LOADS","authors":"Muhammad Rifat Hidayat, Ahmad Basshofi Habieb, Wahyuniarih Sutrisno","doi":"10.12962/j20861206.v38i2.17405","DOIUrl":null,"url":null,"abstract":"Unreinforced Masonry (URM), Confined Masonry (CM), and non-engineered systems in residential buildings in rural and urban areas of Yogyakarta, West Java, and West Sumatra provinces yielded the following results: In rural areas:63% of the surveyed buildings adopted the URM system.8% of the surveyed buildings utilized the CM system.29% of the surveyed buildings were categorized as non-engineered structures.In urban areas: 16% of the surveyed buildings were constructed using the URM system. 66% of the surveyed buildings employed the CM system. 18% of the surveyed buildings were classified as non-engineered Abstract Indonesia was located in a seismically active region and was situated between three tectonic plates. The construction resilience that met the requirements was necessary in earthquake-prone areas. The purpose was to protect and reduce the risk of severe damage caused by significant seismic loads. However, more than 70% of buildings in developing countries like Indonesia utilized the Confined Masonry (CM) structural system. The implementation of CM systems in Indonesia often led to fatal damages during earthquakes. Due to the severity of these damages, the addition of reinforcement systems to CM became one of the options to address the shortcomings of the CM system. There were various types of materials that could be used as reinforcement, such as steel cages, polymers, polypropylene bands, bamboo meshes, and plastic materials. This study investigated the utilization of ferrocement layers as reinforcement material for CM structural system panels. The specimen panels used had a width of 2300 mm and a height of 1370 mm. The specimens in the research were numerically modeled using the ABAQUS/explicit program. The research variation focused on the influence of the wiremesh sheet orientation angle. The number of variations for the ferrocement layer was one layer with angle configurations of 0, 45, and 60 degrees. This reinforcement layer was applied to one side of the CM panel. As a comparison, results from the control specimen were included. The hysteresis curve, energy dissipation, stiffness degradation, and damage patterns were evaluated in this research.","PeriodicalId":9414,"journal":{"name":"Canadian Journal of Civil Engineering","volume":"67 1","pages":"0"},"PeriodicalIF":1.1000,"publicationDate":"2023-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Journal of Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12962/j20861206.v38i2.17405","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0
Abstract
Unreinforced Masonry (URM), Confined Masonry (CM), and non-engineered systems in residential buildings in rural and urban areas of Yogyakarta, West Java, and West Sumatra provinces yielded the following results: In rural areas:63% of the surveyed buildings adopted the URM system.8% of the surveyed buildings utilized the CM system.29% of the surveyed buildings were categorized as non-engineered structures.In urban areas: 16% of the surveyed buildings were constructed using the URM system. 66% of the surveyed buildings employed the CM system. 18% of the surveyed buildings were classified as non-engineered Abstract Indonesia was located in a seismically active region and was situated between three tectonic plates. The construction resilience that met the requirements was necessary in earthquake-prone areas. The purpose was to protect and reduce the risk of severe damage caused by significant seismic loads. However, more than 70% of buildings in developing countries like Indonesia utilized the Confined Masonry (CM) structural system. The implementation of CM systems in Indonesia often led to fatal damages during earthquakes. Due to the severity of these damages, the addition of reinforcement systems to CM became one of the options to address the shortcomings of the CM system. There were various types of materials that could be used as reinforcement, such as steel cages, polymers, polypropylene bands, bamboo meshes, and plastic materials. This study investigated the utilization of ferrocement layers as reinforcement material for CM structural system panels. The specimen panels used had a width of 2300 mm and a height of 1370 mm. The specimens in the research were numerically modeled using the ABAQUS/explicit program. The research variation focused on the influence of the wiremesh sheet orientation angle. The number of variations for the ferrocement layer was one layer with angle configurations of 0, 45, and 60 degrees. This reinforcement layer was applied to one side of the CM panel. As a comparison, results from the control specimen were included. The hysteresis curve, energy dissipation, stiffness degradation, and damage patterns were evaluated in this research.
期刊介绍:
The Canadian Journal of Civil Engineering is the official journal of the Canadian Society for Civil Engineering. It contains articles on environmental engineering, hydrotechnical engineering, structural engineering, construction engineering, engineering mechanics, engineering materials, and history of civil engineering. Contributors include recognized researchers and practitioners in industry, government, and academia. New developments in engineering design and construction are also featured.