Numerical investigation of indoor thermal comfort and air quality for an office equipped with corner impinging jet ventilation

IF 2.1 Q2 CONSTRUCTION & BUILDING TECHNOLOGY Advances in Building Energy Research Pub Date : 2023-10-17 DOI:10.1080/17512549.2023.2269925
Arman Ameen, Mathias Cehlin, Taghi Karimipanah
{"title":"Numerical investigation of indoor thermal comfort and air quality for an office equipped with corner impinging jet ventilation","authors":"Arman Ameen, Mathias Cehlin, Taghi Karimipanah","doi":"10.1080/17512549.2023.2269925","DOIUrl":null,"url":null,"abstract":"This study investigates the feasibility of using only corner impinging jet ventilation (CIJV) for heating and cooling a medium-sized office space with two occupants while maintaining adequate indoor thermal comfort and air quality compared to traditional mixing ventilation systems. This study examines what impact various outdoor temperatures, ranging from −15°C to 25°C, have on an office environment in terms of indoor thermal comfort and air quality. Three different workspace positions were evaluated. The results show that the CIJV system meets the ASHRAE thermal comfort standards for all three positions. In terms of indoor air quality, CIJV performs better than traditional mixing systems, with improved mean age of air and ACE values. This study concludes that CIJV can be used both close and far away from the supply inlets and still provide adequate indoor thermal comfort and air quality during both cooling and heating season.","PeriodicalId":46184,"journal":{"name":"Advances in Building Energy Research","volume":"195 1","pages":"0"},"PeriodicalIF":2.1000,"publicationDate":"2023-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Building Energy Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17512549.2023.2269925","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

This study investigates the feasibility of using only corner impinging jet ventilation (CIJV) for heating and cooling a medium-sized office space with two occupants while maintaining adequate indoor thermal comfort and air quality compared to traditional mixing ventilation systems. This study examines what impact various outdoor temperatures, ranging from −15°C to 25°C, have on an office environment in terms of indoor thermal comfort and air quality. Three different workspace positions were evaluated. The results show that the CIJV system meets the ASHRAE thermal comfort standards for all three positions. In terms of indoor air quality, CIJV performs better than traditional mixing systems, with improved mean age of air and ACE values. This study concludes that CIJV can be used both close and far away from the supply inlets and still provide adequate indoor thermal comfort and air quality during both cooling and heating season.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
角撞式射流通风办公室室内热舒适与空气质量数值研究
与传统的混合通风系统相比,本研究调查了仅使用角落撞击式射流通风(CIJV)为两名居住者的中型办公空间供暖和制冷的可行性,同时保持足够的室内热舒适和空气质量。本研究考察了从- 15°C到25°C的不同室外温度对室内热舒适和空气质量的影响。评估了三种不同的工作空间位置。结果表明,CIJV系统在三个位置均满足ASHRAE热舒适标准。在室内空气质量方面,CIJV比传统混合系统表现更好,空气平均年龄和ACE值都有所提高。本研究得出结论,无论是在供气入口附近还是在供气入口附近,CIJV都可以使用,并且在制冷和制热季节仍然提供足够的室内热舒适和空气质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Advances in Building Energy Research
Advances in Building Energy Research CONSTRUCTION & BUILDING TECHNOLOGY-
CiteScore
4.80
自引率
5.00%
发文量
11
期刊最新文献
Numerical study on thermal performance of a building design integrating two passive Trombe walls Impact of courtyard on indoor thermal environment in vernacular row houses of warm and humid climate: case study of Kanyakumari, Tamil Nadu Capillary sorption, thermo physical characterizations and simulation study of an eco-friendly building material reinforced with Chamarrops humilis fibres Numerical investigation of indoor thermal comfort and air quality for an office equipped with corner impinging jet ventilation Research on the thermal environment in a climate chamber with different high-temperature combinations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1