Effect of Perforated Sills on Maximum Scour Depth Downstream From a Sluice Gate

Elsayed M. Elshahat, Gamal M. AbdelAal, Samar Hassan, Eslam Eltohamy
{"title":"Effect of Perforated Sills on Maximum Scour Depth Downstream From a Sluice Gate","authors":"Elsayed M. Elshahat, Gamal M. AbdelAal, Samar Hassan, Eslam Eltohamy","doi":"10.2174/18741495-v17-e230906-2023-21","DOIUrl":null,"url":null,"abstract":"Aims: Experiments were conducted to study the effect of using a perforated sill on maximum scour depth downstream from a sluice gate. Background: Previous studies have shown that screens may be utilized efficiently for dissipating the energy of water downstream of a hydraulic structure. Objective: For the present study, a series of experiments was conducted to investigate the effect of using a perforated screen sill on the maximum scour depth downstream of a hydraulic structure. Methods: In the present study, a single perforated sill with varying porosity (10.3%, 18.3%, 28.5%, and 41.1%) and an inclination angle of 90° were used. Perforated sill with different shapes of holes (circular, rectangular, and square holes) was used during the study. The major parameters for the present study are the porosity of the perforated sill, different shapes of holes, downstream water depth, and the Gate Froude number (F G ) for a range covering from 2.15 to 4.7. The gate opening simulating a hydraulic structure is adjusted at heights of 4 cm, 5 cm, and 6 cm during the experiments work. Result: The results revealed that an increase in the sill porosity (Ao/As) increases the screen effect to reduce the max scour depth. In addition, the results showed that the sill with square holes is better than the sill with circular and rectangular holes in reducing the maximum scour depth. Conclusion: The perforated sill with a square porosity of 41.1% reduces the maximum scour depth downstream of a sluice gate by 60%.","PeriodicalId":350575,"journal":{"name":"The Open Civil Engineering Journal","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Open Civil Engineering Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/18741495-v17-e230906-2023-21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: Experiments were conducted to study the effect of using a perforated sill on maximum scour depth downstream from a sluice gate. Background: Previous studies have shown that screens may be utilized efficiently for dissipating the energy of water downstream of a hydraulic structure. Objective: For the present study, a series of experiments was conducted to investigate the effect of using a perforated screen sill on the maximum scour depth downstream of a hydraulic structure. Methods: In the present study, a single perforated sill with varying porosity (10.3%, 18.3%, 28.5%, and 41.1%) and an inclination angle of 90° were used. Perforated sill with different shapes of holes (circular, rectangular, and square holes) was used during the study. The major parameters for the present study are the porosity of the perforated sill, different shapes of holes, downstream water depth, and the Gate Froude number (F G ) for a range covering from 2.15 to 4.7. The gate opening simulating a hydraulic structure is adjusted at heights of 4 cm, 5 cm, and 6 cm during the experiments work. Result: The results revealed that an increase in the sill porosity (Ao/As) increases the screen effect to reduce the max scour depth. In addition, the results showed that the sill with square holes is better than the sill with circular and rectangular holes in reducing the maximum scour depth. Conclusion: The perforated sill with a square porosity of 41.1% reduces the maximum scour depth downstream of a sluice gate by 60%.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
孔坝对闸门下游最大冲刷深度的影响
目的:通过试验研究了在水闸下游设置孔洞对最大冲刷深度的影响。背景:先前的研究表明,筛网可以有效地用于消散水工结构下游水的能量。目的:本研究通过一系列试验,探讨了在水工构筑物下游使用多孔筛网对最大冲刷深度的影响。方法:采用不同孔隙度(10.3%、18.3%、28.5%、41.1%)、倾角为90°的单孔储层。在研究中使用了不同形状孔(圆形孔、矩形孔和方孔)的穿孔窗台。本研究的主要参数为孔洞的孔隙率、孔洞的不同形状、下游水深和Gate - Froude数(F G),取值范围为2.15 ~ 4.7。模拟水工结构的闸门开度在实验工作中分别在4cm、5cm、6cm高度进行调整。结果:孔隙率(Ao/As)的增加增加了筛分效应,减小了最大冲刷深度。此外,结果表明,方形孔的井架在降低最大冲刷深度方面优于圆形孔和矩形孔的井架。结论:方孔率为41.1%的孔洞使闸门下游最大冲刷深度降低60%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Selection of Building Materials Using Fuzzy Analytical Hierarchy Process Sewer Inlets Detection in UAV Images Clouds based on Convolution Neural Networks Effect of Magnetized Water on Partially Replaced Aggregate with Silica Sand in Concrete Speed Corridor Enforcement System (SCES) - A Case Study of the Highways of Kosovo Determination of Temperature Stresses during the Construction of Massive Monolithic Foundation Slabs, Taking into Account the Subgrade Compliance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1