{"title":"A Highly Promising Flower-Shaped WO2I2/Poly(1H-Pyrrole) Nanocomposite Thin Film as a Potentiometric Sensor for the Detection of Cd2+ Ions in Water","authors":"Maha Abdallah Alnuwaiser, Mohamed Rabia","doi":"10.3390/jcs7100439","DOIUrl":null,"url":null,"abstract":"Because of the expensive nature of sensors used to detect heavy metals and the severe health risks associated with certain heavy metals, there is a pressing need to develop cost-effective materials that are highly efficient in detecting these metals. A flower-shaped WO2I2-Poly(1H-pyrrole) (WO2I2/P1HP) nanocomposite thin film is synthesized through the oxidation of 1-H pyrrole using iodine and subsequent reaction with Na2WO4. The nanocomposite exhibits a distinctive flower-like morphology with an average size of 20 nm. Elemental composition and chemical structure are confirmed via X-ray photoelectron spectroscopy (XPS) analyses, while X-Ray diffraction analysis (XRD) and Fourier-transform infrared spectroscopy (FTIR) analyses provide further evidence of crystalline peaks and functional groups within the composite. The potential of the nanocomposite as a sensor for Cd2+ ions is determined using two approaches: simple potentiometric (two-electrode cell) and cyclic voltammetric (three-electrode cell) methods, over a concentration range spanning from 10−6 to 10−1 M. From the simple potentiometric method, the sensor showcases strong sensing capabilities in the concentration span of 10−4 to 10−1 M, displaying a Nernstian slope of 29.7 mV/decade. With a detection limit of 5 × 10−5 M, the sensor proves adept at precise and sensitive detection of low Cd2+ ion concentrations. While using the cyclic voltammetric method, the sensor’s selectivity for Cd2+ ions, demonstrated through cyclic voltammetry, reveals a sensitivity of 1.0 × 10−5 A/M and the ability to distinguish Cd2+ ions from other ions like Zn2+, Ni2+, Ca2+, K+, Al3+, and Mg2+. This selectivity underscores its utility in complex sample matrices and diverse environments. Furthermore, the sensor’s successful detection of Cd2+ ions from real samples solidifies its practical viability. Its reliable performance in real-world scenarios positions it as a valuable tool for Cd2+ ion detection across industries and environmental monitoring applications. These findings advocate for its utilization in commercial settings, highlighting its significance in Cd2+ ion detection.","PeriodicalId":15435,"journal":{"name":"Journal of Composites Science","volume":"36 1","pages":"0"},"PeriodicalIF":3.0000,"publicationDate":"2023-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Composites Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/jcs7100439","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, COMPOSITES","Score":null,"Total":0}
引用次数: 0
Abstract
Because of the expensive nature of sensors used to detect heavy metals and the severe health risks associated with certain heavy metals, there is a pressing need to develop cost-effective materials that are highly efficient in detecting these metals. A flower-shaped WO2I2-Poly(1H-pyrrole) (WO2I2/P1HP) nanocomposite thin film is synthesized through the oxidation of 1-H pyrrole using iodine and subsequent reaction with Na2WO4. The nanocomposite exhibits a distinctive flower-like morphology with an average size of 20 nm. Elemental composition and chemical structure are confirmed via X-ray photoelectron spectroscopy (XPS) analyses, while X-Ray diffraction analysis (XRD) and Fourier-transform infrared spectroscopy (FTIR) analyses provide further evidence of crystalline peaks and functional groups within the composite. The potential of the nanocomposite as a sensor for Cd2+ ions is determined using two approaches: simple potentiometric (two-electrode cell) and cyclic voltammetric (three-electrode cell) methods, over a concentration range spanning from 10−6 to 10−1 M. From the simple potentiometric method, the sensor showcases strong sensing capabilities in the concentration span of 10−4 to 10−1 M, displaying a Nernstian slope of 29.7 mV/decade. With a detection limit of 5 × 10−5 M, the sensor proves adept at precise and sensitive detection of low Cd2+ ion concentrations. While using the cyclic voltammetric method, the sensor’s selectivity for Cd2+ ions, demonstrated through cyclic voltammetry, reveals a sensitivity of 1.0 × 10−5 A/M and the ability to distinguish Cd2+ ions from other ions like Zn2+, Ni2+, Ca2+, K+, Al3+, and Mg2+. This selectivity underscores its utility in complex sample matrices and diverse environments. Furthermore, the sensor’s successful detection of Cd2+ ions from real samples solidifies its practical viability. Its reliable performance in real-world scenarios positions it as a valuable tool for Cd2+ ion detection across industries and environmental monitoring applications. These findings advocate for its utilization in commercial settings, highlighting its significance in Cd2+ ion detection.