Experimental study of air source heat pump water heater: Energy, exergy, and entransy analysis

Q1 Engineering Energy and Built Environment Pub Date : 2023-10-26 DOI:10.1016/j.enbenv.2023.10.006
Fang Ruan, Saisai Xu, Dingye Qin, Shun Li, Pengxu Chen
{"title":"Experimental study of air source heat pump water heater: Energy, exergy, and entransy analysis","authors":"Fang Ruan,&nbsp;Saisai Xu,&nbsp;Dingye Qin,&nbsp;Shun Li,&nbsp;Pengxu Chen","doi":"10.1016/j.enbenv.2023.10.006","DOIUrl":null,"url":null,"abstract":"<div><div>With the continuous progress of urbanization, building energy consumption is increasing dramatically. At present, energy consumption caused by air conditioning accounts for a half in typical building energy consumption in China. Using exergy and entransy analysis, this paper experimentally studies the thermal performance of an air source heat pump water heater and its components under different meteorological conditions. This paper, for the first time, introduces the dimensionless number of entransy dissipation ratio (EDR), namely the percentage of a component's entransy dissipation into the entire system. The findings indicate that with the increase in air temperature, the heat production, the EDR of condenser and evaporator, and the exergy efficiency of condenser and compressor increase while the exergic efficiency of evaporator and throttle valve decrease. In the case of increased air flow rate, the heat production and exergy destruction of water heater as well as the EDR of evaporator are enhanced, while the exergy efficiency of evaporator, compressor and throttle and the EDR of condenser decrease, with the exergy efficiency of the throttle remaining the highest. The irreversibility rates of components are affected by change in the relative humidity of air, which is specified as follows: The percentage range of irreversibility rates for compressor, condenser, throttle and evaporator is 11.5–16 %, 37–45 %, 6.8–11.5 % and 32–41 %, respectively.</div></div>","PeriodicalId":33659,"journal":{"name":"Energy and Built Environment","volume":"6 2","pages":"Pages 187-200"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy and Built Environment","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666123323001022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

With the continuous progress of urbanization, building energy consumption is increasing dramatically. At present, energy consumption caused by air conditioning accounts for a half in typical building energy consumption in China. Using exergy and entransy analysis, this paper experimentally studies the thermal performance of an air source heat pump water heater and its components under different meteorological conditions. This paper, for the first time, introduces the dimensionless number of entransy dissipation ratio (EDR), namely the percentage of a component's entransy dissipation into the entire system. The findings indicate that with the increase in air temperature, the heat production, the EDR of condenser and evaporator, and the exergy efficiency of condenser and compressor increase while the exergic efficiency of evaporator and throttle valve decrease. In the case of increased air flow rate, the heat production and exergy destruction of water heater as well as the EDR of evaporator are enhanced, while the exergy efficiency of evaporator, compressor and throttle and the EDR of condenser decrease, with the exergy efficiency of the throttle remaining the highest. The irreversibility rates of components are affected by change in the relative humidity of air, which is specified as follows: The percentage range of irreversibility rates for compressor, condenser, throttle and evaporator is 11.5–16 %, 37–45 %, 6.8–11.5 % and 32–41 %, respectively.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
空气源热泵热水器的实验研究:能量、火用和能量分析
随着城市化进程的不断推进,建筑能耗急剧增加。目前,空调能耗占中国典型建筑能耗的一半。采用火用和能量分析方法,对空气源热泵热水器及其部件在不同气象条件下的热性能进行了实验研究。本文首次引入了无因次熵耗散比(EDR),即部件的熵耗散占整个系统的百分比。结果表明:随着空气温度的升高,冷凝器和蒸发器的产热量、EDR以及冷凝器和压缩机的火用效率均增加,而蒸发器和节流阀的火用效率则降低;在空气流量增大的情况下,热水器的产热和火用破坏以及蒸发器的EDR均有所提高,蒸发器、压缩机和节流阀的火用效率和冷凝器的EDR均有所降低,其中节流阀的火用效率最高。部件的不可逆性受空气相对湿度变化的影响,具体规定如下:压缩机、冷凝器、节流阀、蒸发器的不可逆性百分比范围分别为11.5 ~ 16%、37 ~ 45%、6.8 ~ 11.5%、32 ~ 41%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Energy and Built Environment
Energy and Built Environment Engineering-Building and Construction
CiteScore
15.90
自引率
0.00%
发文量
104
审稿时长
49 days
期刊最新文献
Editorial Board Thermoeconomic assessment of the air-cooled tropical data center through energy-saving strategies Spray field characteristics and the effect of spray-local exhaust ventilation on the control of high-temperature buoyant jets Sorption kinetics of vermiculite-K2CO3 in thermochemical energy storage: Model evaluation and mechanism exploration Study on the deposition characteristics of fine particles at local components in air conditioning ventilation ducts
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1