Blood pressure variability from intra-arterial pressure recordings in humans

Q4 Pharmacology, Toxicology and Pharmaceutics Indian journal of physiology and pharmacology Pub Date : 2023-09-09 DOI:10.25259/ijpp_61_2023
Farhan Adam Mukadam, Naveen Gangadharan, Bowya Baskaran, S. Baskaran, Subramani Kandasamy, Syrpailyne Wankhar, Suresh Devasahayam, Sathya Subramani
{"title":"Blood pressure variability from intra-arterial pressure recordings in humans","authors":"Farhan Adam Mukadam, Naveen Gangadharan, Bowya Baskaran, S. Baskaran, Subramani Kandasamy, Syrpailyne Wankhar, Suresh Devasahayam, Sathya Subramani","doi":"10.25259/ijpp_61_2023","DOIUrl":null,"url":null,"abstract":"Objectives: The study presents the magnitude of variation of systolic and diastolic pressures over a few minutes from intra-arterial pressure recordings in 51 hemodynamically stable patients in an intensive care unit. Materials and Methods: Conscious surgical ICU patients, with arterial pressure cannulae placed as the standard of care, were recruited after obtaining informed consent. A validated data acquisition system was used to record intra-arterial blood pressure for a period of 10 minutes following a Fast-Flush test. Only those recordings with acceptable dynamic characteristics as per Gardner’s criteria were included in the analysis. Results: Three categories of systolic and diastolic pressure variability namely “beat-to-beat” variability, “Respiratory” variability, and “Total magnitude of variation” during the duration of recording, were reported for each of the 51 patients. The mean (± SD) of the total magnitude of variation for systolic and diastolic pressures in the study sample were 21 ± 9 mmHg and 14 ± 5 mmHg respectively. Conclusion: Given the magnitude of systolic and diastolic pressure variations over a few minutes, the validity of reporting single- point values for these pressures and using single-point cut-offs for diagnosis and treatment of hypertension must be re-evaluated.","PeriodicalId":13367,"journal":{"name":"Indian journal of physiology and pharmacology","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian journal of physiology and pharmacology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25259/ijpp_61_2023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The study presents the magnitude of variation of systolic and diastolic pressures over a few minutes from intra-arterial pressure recordings in 51 hemodynamically stable patients in an intensive care unit. Materials and Methods: Conscious surgical ICU patients, with arterial pressure cannulae placed as the standard of care, were recruited after obtaining informed consent. A validated data acquisition system was used to record intra-arterial blood pressure for a period of 10 minutes following a Fast-Flush test. Only those recordings with acceptable dynamic characteristics as per Gardner’s criteria were included in the analysis. Results: Three categories of systolic and diastolic pressure variability namely “beat-to-beat” variability, “Respiratory” variability, and “Total magnitude of variation” during the duration of recording, were reported for each of the 51 patients. The mean (± SD) of the total magnitude of variation for systolic and diastolic pressures in the study sample were 21 ± 9 mmHg and 14 ± 5 mmHg respectively. Conclusion: Given the magnitude of systolic and diastolic pressure variations over a few minutes, the validity of reporting single- point values for these pressures and using single-point cut-offs for diagnosis and treatment of hypertension must be re-evaluated.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人类动脉内血压记录的血压变异性
目的:本研究介绍了51例重症监护病房血流动力学稳定患者的动脉内压记录在几分钟内收缩压和舒张压的变化幅度。材料与方法:在征得知情同意后,以动脉压插管为护理标准招募意识清醒的外科ICU患者。使用经过验证的数据采集系统记录快速冲洗试验后10分钟的动脉内血压。根据Gardner的标准,只有那些具有可接受动态特性的录音才被包括在分析中。结果:在记录期间,51例患者的收缩压和舒张压变异性有三种类型,即“搏动”变异性、“呼吸”变异性和“总变异性”。研究样本中收缩压和舒张压总变化幅度的平均值(±SD)分别为21±9 mmHg和14±5 mmHg。结论:考虑到几分钟内收缩压和舒张压的变化幅度,报告这些压力的单点值和使用单点截止值诊断和治疗高血压的有效性必须重新评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Indian journal of physiology and pharmacology
Indian journal of physiology and pharmacology Pharmacology, Toxicology and Pharmaceutics-Pharmacology
CiteScore
0.50
自引率
0.00%
发文量
35
期刊介绍: Indian Journal of Physiology and Pharmacology (IJPP) welcomes original manuscripts based upon research in physiological, pharmacological and allied sciences from any part of the world.
期刊最新文献
A randomised controlled trial of mindfulness-based stress reduction programme for substance abuse patients in deaddiction centre Faculty perceptions of the efficacy, benefits and challenges of simulation-based early clinical exposure for medical students in India: A qualitative study Oesophageal pressure topographic metrics in refractory gastroesophageal reflux disease: An Indian perspective Erratum: Breath characteristics in four volitional yoga breathing practices Deep brain stimulation for the heterogeneous pathophysiology of Parkinson’s disease
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1