Qualification and optimisation of a gas mixing apparatus for complex trace gas mixtures

IF 0.8 4区 工程技术 Q4 INSTRUMENTS & INSTRUMENTATION Tm-Technisches Messen Pub Date : 2023-10-11 DOI:10.1515/teme-2023-0075
Dennis Arendes, Johannes Amann, Cyril Tessier, Oliver Brieger, Andreas Schütze, Christian Bur
{"title":"Qualification and optimisation of a gas mixing apparatus for complex trace gas mixtures","authors":"Dennis Arendes, Johannes Amann, Cyril Tessier, Oliver Brieger, Andreas Schütze, Christian Bur","doi":"10.1515/teme-2023-0075","DOIUrl":null,"url":null,"abstract":"Abstract A gas mixing apparatus (GMA) can provide well-defined gas mixtures, which are necessary to calibrate gas sensors for quantitative measurements. This article presents a novel modular GMA and especially the representative measurements carried out to qualify and quantify its performance. New methods were developed to optimise the GMA’s settling speed and to enable self-monitoring. The GMA is able to provide up to 14 individual test gases, each in a large concentration range from sub-parts-per-billion to hundreds of parts-per-millions. Additionally, the relative humidity can be set. The system is able to provide stable gas mixtures in approximately 6 min. The entire control software is realised in Python, which determines the control setpoints of all relevant system components based on the concentration input of the user. A major focus was placed on minimising the time of a gas mixture exchange to confirm design and additional software optimisation. Also, a number of techniques are shown for the analytical quantification of the system, including analysis of thermal desorption tubes by an accredited laboratory, showing maximal contaminations of e.g. only 4.18 ppb ethanol. Finally, self-monitoring of the system using photoionization detectors (PID) is demonstrated as an addition to flow readback for internal leakage detection.","PeriodicalId":56086,"journal":{"name":"Tm-Technisches Messen","volume":"59 1","pages":"0"},"PeriodicalIF":0.8000,"publicationDate":"2023-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tm-Technisches Messen","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/teme-2023-0075","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract A gas mixing apparatus (GMA) can provide well-defined gas mixtures, which are necessary to calibrate gas sensors for quantitative measurements. This article presents a novel modular GMA and especially the representative measurements carried out to qualify and quantify its performance. New methods were developed to optimise the GMA’s settling speed and to enable self-monitoring. The GMA is able to provide up to 14 individual test gases, each in a large concentration range from sub-parts-per-billion to hundreds of parts-per-millions. Additionally, the relative humidity can be set. The system is able to provide stable gas mixtures in approximately 6 min. The entire control software is realised in Python, which determines the control setpoints of all relevant system components based on the concentration input of the user. A major focus was placed on minimising the time of a gas mixture exchange to confirm design and additional software optimisation. Also, a number of techniques are shown for the analytical quantification of the system, including analysis of thermal desorption tubes by an accredited laboratory, showing maximal contaminations of e.g. only 4.18 ppb ethanol. Finally, self-monitoring of the system using photoionization detectors (PID) is demonstrated as an addition to flow readback for internal leakage detection.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于复杂微量气体混合物的气体混合装置的鉴定和优化
摘要气体混合装置(GMA)可以提供定义良好的气体混合物,这是校准气体传感器进行定量测量所必需的。本文介绍了一种新型模块化GMA,特别是进行了具有代表性的测量,以确定和量化其性能。开发了新的方法来优化GMA的沉降速度并实现自我监测。GMA能够提供多达14种单独的测试气体,每种气体的浓度范围从十亿分之一到百万分之数百。另外,还可以设置相对湿度。该系统能够在大约6分钟内提供稳定的气体混合物。整个控制软件是用Python实现的,它根据用户的浓度输入确定所有相关系统组件的控制设定值。主要的重点是尽量减少气体混合物交换的时间,以确认设计和额外的软件优化。此外,还展示了许多用于系统分析定量的技术,包括由认可的实验室对热脱附管的分析,显示最大污染例如仅为4.18 ppb乙醇。最后,使用光电离检测器(PID)对系统进行自我监控,作为内部泄漏检测的流量回读的补充。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Tm-Technisches Messen
Tm-Technisches Messen 工程技术-仪器仪表
CiteScore
1.70
自引率
20.00%
发文量
105
审稿时长
6-12 weeks
期刊介绍: The journal promotes dialogue between the developers of application-oriented sensors, measurement systems, and measurement methods and the manufacturers and measurement technologists who use them. Topics The manufacture and characteristics of new sensors for measurement technology in the industrial sector New measurement methods Hardware and software based processing and analysis of measurement signals to obtain measurement values The outcomes of employing new measurement systems and methods.
期刊最新文献
Miniaturisation of label free surface analytics by Whispering Gallery Modes Number of samples to use in estimating sinewave amplitude in the presence of noise Frontmatter 16th Dresden Sensor Symposium Integrating metrological principles into the Internet of Things: a digital maturity model for sensor network metrology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1