{"title":"Present Status of the Effectiveness of the Patch Test Reagent for Titanium Hypersensitivity","authors":"Mari Koike, Hummel Susan, Haruto Hiraba, Saiji Shimoe","doi":"10.12974/2311-8695.2023.11.07","DOIUrl":null,"url":null,"abstract":"Titanium and titanium alloys have been used for dental implants, due to their excellent biocompatibility and suitable mechanical properties. The frequency in use of titanium and titanium alloys for dental applications has gradually increased. For example, in 2020, a Japanese insurance approved the use of pure titanium for posterior molars as a metallic cast crown. Titanium alloys have also been used for frameworks of removable partial denture. Allergic reactions to titanium and titanium alloys are rare but do occur. One theory of unexplained implant loss is that the patient is hypersensitive to titanium. The hypersensitivity causes an inflammatory reaction to the implant body and failure to osseointegrate, resulting in implant failure. The patch test for diagnosis of titanium hypersensitivity has been unreliable because the result of the patch test does not match the clinical symptoms. Standard titanium reagents for patch tests are needed for accurate diagnosis of titanium hypersensitivity to prevent the failure of implants.
 The objective of this review was to evaluate literature reporting the status of allergic diagnosis for titanium hypersensitivity and analyze the results mentioned. Based on these results, a possible standardization of the titanium reagent for the patch test were discussed. These searched literatures indicated that further national and/or registry based studies will be needed to better inform clinical practice and to identify the scale of metal sensitivity, clear diagnostic criteria, and long-term clinical performance data on hypoallergenic implants.","PeriodicalId":76664,"journal":{"name":"The Journal of the American College of Dentists","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of the American College of Dentists","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12974/2311-8695.2023.11.07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Titanium and titanium alloys have been used for dental implants, due to their excellent biocompatibility and suitable mechanical properties. The frequency in use of titanium and titanium alloys for dental applications has gradually increased. For example, in 2020, a Japanese insurance approved the use of pure titanium for posterior molars as a metallic cast crown. Titanium alloys have also been used for frameworks of removable partial denture. Allergic reactions to titanium and titanium alloys are rare but do occur. One theory of unexplained implant loss is that the patient is hypersensitive to titanium. The hypersensitivity causes an inflammatory reaction to the implant body and failure to osseointegrate, resulting in implant failure. The patch test for diagnosis of titanium hypersensitivity has been unreliable because the result of the patch test does not match the clinical symptoms. Standard titanium reagents for patch tests are needed for accurate diagnosis of titanium hypersensitivity to prevent the failure of implants. The objective of this review was to evaluate literature reporting the status of allergic diagnosis for titanium hypersensitivity and analyze the results mentioned. Based on these results, a possible standardization of the titanium reagent for the patch test were discussed. These searched literatures indicated that further national and/or registry based studies will be needed to better inform clinical practice and to identify the scale of metal sensitivity, clear diagnostic criteria, and long-term clinical performance data on hypoallergenic implants.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
钛超敏性斑贴试验试剂的有效性现状
钛及钛合金由于其优良的生物相容性和适宜的力学性能,已被广泛用于种植牙材料。钛及钛合金在牙科应用中的使用频率逐渐增加。例如,在2020年,一家日本保险公司批准将纯钛作为金属铸造冠用于后磨牙。钛合金也被用于可摘局部义齿的框架。对钛和钛合金的过敏反应很少见,但确实会发生。一种无法解释植入物丢失的理论是病人对钛过敏。这种过敏反应会引起对种植体的炎症反应和骨整合失败,导致种植体失败。由于斑贴试验的结果与临床症状不相符,因此诊断钛超敏反应的斑贴试验并不可靠。为了准确诊断钛超敏,防止种植体失效,需要使用标准的钛试剂进行贴片试验。 本综述的目的是评价文献报道的钛超敏反应的过敏诊断状况,并分析所提到的结果。在此基础上,对贴片试验用钛试剂的标准化进行了探讨。这些检索到的文献表明,需要进一步的全国性和/或基于注册的研究来更好地为临床实践提供信息,并确定金属敏感性的规模,明确的诊断标准,以及低过敏性植入物的长期临床表现数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Usage of Antimicrobials in Pediatric Dentistry- A Narrative Review Present Status of the Effectiveness of the Patch Test Reagent for Titanium Hypersensitivity Effect of Leukocyte- and Platelet-Rich Fibrin in Postoperative Recovery Following Impacted Mandibular Third Molar Surgery: A Split Mouth Study Comparison of Shear Bond Strength and Adhesive Remnant Index of Two Different Primers in Dry and Wet Conditions An Overview of Basic Concepts of Finite Element Analysis and Its Applications in Orthodontics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1