Method for accuracy assessment of topo-bathymetric surface models based on geospatial data recorded by UAV and USV vehicles

IF 1 4区 工程技术 Q4 INSTRUMENTS & INSTRUMENTATION Metrology and Measurement Systems Pub Date : 2023-10-27 DOI:10.24425/mms.2023.146421
{"title":"Method for accuracy assessment of topo-bathymetric surface models based on geospatial data recorded by UAV and USV vehicles","authors":"","doi":"10.24425/mms.2023.146421","DOIUrl":null,"url":null,"abstract":"Geospatial data obtained using Unmanned Aerial Vehicles (UAVs) and Unmanned Surface Vehicles (USVs) are increasingly used to model the terrain in the coastal zone, in particular in shallow waterbodies (with a depth of up to 1 m). In order to generate a terrain relief, it is important to choose a method for modelling that will allow it to be accurately projected. Therefore, the aim of this article is to present a method for accuracy assessment of topo-bathymetric surface models based on geospatial data recorded by UAV and USV vehicles. Bathymetric and photogrammetric measurements were carried out on the waterbody adjacent to the public beach in Gdynia (Poland) in 2022 using a DJI Phantom 4 RTK UAV and an AutoDron USV. The geospatial data integration process was performed in the Surfer software. As a result, Digital Terrain Models (DTMs) in the coastal zone were developed using the following terrain modelling methods: Inverse Distance to a Power (IDP), Inverse Distance Weighted (IDW), kriging, the Modified Shepard’s Method (MSM) and Natural Neighbour Interpolation (NNI). The conducted study does not clearly indicate any of the methods, as the selection of the method is also affected by the visualization of the generated model. However, having compared the accuracy measures of the charts and models obtained, it was concluded that for this type of data, the kriging (linear model) method was the best. Very good results were also obtained for the NNI method. The lowest value of the Root Mean Square Error (RMSE) (0.030 m) and the lowest value of the Mean Absolute Error (MAE) (0.011 m) were noted for the GRID model interpolated with the kriging (linear model) method. Moreover, the NNI and kriging (linear model) methods obtained the highest coefficient of determination value (0.999). The NNI method has the lowest value of the R68 measure (0.009 m), while the lowest value of the R95 measure (0.033 m) was noted for the kriging (linear model) method.","PeriodicalId":18394,"journal":{"name":"Metrology and Measurement Systems","volume":"59 4","pages":"0"},"PeriodicalIF":1.0000,"publicationDate":"2023-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metrology and Measurement Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24425/mms.2023.146421","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Geospatial data obtained using Unmanned Aerial Vehicles (UAVs) and Unmanned Surface Vehicles (USVs) are increasingly used to model the terrain in the coastal zone, in particular in shallow waterbodies (with a depth of up to 1 m). In order to generate a terrain relief, it is important to choose a method for modelling that will allow it to be accurately projected. Therefore, the aim of this article is to present a method for accuracy assessment of topo-bathymetric surface models based on geospatial data recorded by UAV and USV vehicles. Bathymetric and photogrammetric measurements were carried out on the waterbody adjacent to the public beach in Gdynia (Poland) in 2022 using a DJI Phantom 4 RTK UAV and an AutoDron USV. The geospatial data integration process was performed in the Surfer software. As a result, Digital Terrain Models (DTMs) in the coastal zone were developed using the following terrain modelling methods: Inverse Distance to a Power (IDP), Inverse Distance Weighted (IDW), kriging, the Modified Shepard’s Method (MSM) and Natural Neighbour Interpolation (NNI). The conducted study does not clearly indicate any of the methods, as the selection of the method is also affected by the visualization of the generated model. However, having compared the accuracy measures of the charts and models obtained, it was concluded that for this type of data, the kriging (linear model) method was the best. Very good results were also obtained for the NNI method. The lowest value of the Root Mean Square Error (RMSE) (0.030 m) and the lowest value of the Mean Absolute Error (MAE) (0.011 m) were noted for the GRID model interpolated with the kriging (linear model) method. Moreover, the NNI and kriging (linear model) methods obtained the highest coefficient of determination value (0.999). The NNI method has the lowest value of the R68 measure (0.009 m), while the lowest value of the R95 measure (0.033 m) was noted for the kriging (linear model) method.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于无人机和无人潜航器记录的地理空间数据的地形-水深表面模型精度评估方法
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Metrology and Measurement Systems
Metrology and Measurement Systems INSTRUMENTS & INSTRUMENTATION-
CiteScore
2.00
自引率
10.00%
发文量
0
审稿时长
6 months
期刊介绍: Contributions are invited on all aspects of the research, development and applications of the measurement science and technology. The list of topics covered includes: theory and general principles of measurement; measurement of physical, chemical and biological quantities; medical measurements; sensors and transducers; measurement data acquisition; measurement signal transmission; processing and data analysis; measurement systems and embedded systems; design, manufacture and evaluation of instruments. The average publication cycle is 6 months.
期刊最新文献
148534 Selected Technical Issues of Deep Neural Networks for Image Classification Purposes Statistical process control of commercial force-sensing resistors Physical foundations determining spectral characteristics measured in Bragg gratings subjected to bending Anatomical and functional assessment of patency of the upper respiratory tract in selected respiratory disorders – part 2
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1