[The Mevatrom KD 80/67 linear accelerator].

Ceskoslovenska radiologie Pub Date : 1989-11-01
O Ott
{"title":"[The Mevatrom KD 80/67 linear accelerator].","authors":"O Ott","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Technical equipment of radiotherapeutic wards is presently supplemented with irradiators on the principle of a linear accelerator. The paper briefly describes the principle of linear accelerator with standing wave and its basic technical parameters. Data on electric, mechanic and densitometric properties of this apparatus and accessories are presented. Therapeutic beams of bremsstrahlung and electron radiation were characterized in the whole range of energy, i.e. 0.961 and 3.204 pJ (6 and 20 MV) for bremsstrahlung and 0.961 to 3.364 pJ (6 to 21 MeV) for electron radiation. In the last part the performed hygienic measurements are also described.</p>","PeriodicalId":75694,"journal":{"name":"Ceskoslovenska radiologie","volume":"43 6","pages":"377-82"},"PeriodicalIF":0.0000,"publicationDate":"1989-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ceskoslovenska radiologie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Technical equipment of radiotherapeutic wards is presently supplemented with irradiators on the principle of a linear accelerator. The paper briefly describes the principle of linear accelerator with standing wave and its basic technical parameters. Data on electric, mechanic and densitometric properties of this apparatus and accessories are presented. Therapeutic beams of bremsstrahlung and electron radiation were characterized in the whole range of energy, i.e. 0.961 and 3.204 pJ (6 and 20 MV) for bremsstrahlung and 0.961 to 3.364 pJ (6 to 21 MeV) for electron radiation. In the last part the performed hygienic measurements are also described.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mevatrom KD 80/67直线加速器。
放射治疗病房的技术设备目前以直线加速器的原理补充了辐照机。简要介绍了驻波直线加速器的工作原理和基本技术参数。给出了该装置及其附件的电学、力学和密度特性数据。轫致辐射治疗束和电子辐射治疗束在整个能量范围内,轫致辐射治疗束能量为0.961 ~ 3.204 pJ (6 ~ 20 MV),电子辐射治疗束能量为0.961 ~ 3.364 pJ (6 ~ 21 MeV)。最后介绍了所进行的卫生测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Renal oncocytoma]. [Initial experience with high-resolution computer tomography in diffuse pulmonary diseases]. [Deep venous thrombosis of the lower extremities: diagnosis using ultrasonography. I. Methodology and diagnostic criteria in the use of real-time ultrasonography]. [Deep venous thrombosis of the lower extremities: diagnosis using ultrasonography. II. Methodology and diagnostic criteria in the use of duplex ultrasonography; an outline for the differential diagnosis of edema of the lower extremity]. [Postthrombotic syndrome and phlebography. I. Clinical stages of the postthrombotic syndrome, levels of morphologic changes in the venous system and their interrelations].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1